Error description

  • After applying APAR PH59848 fix, if NM108 value is XX and NM109
    is removed then design studio is closing abruptly with no error.
     Removal of APAR does not crash the Design Studio.
    

Local fix

  • ITXCQ - ITX00062419
    MG / LV
    Circumvention: Remove APAR PH59848 fix
    

Problem summary

  • hcsvu exit library crash when executing Type 5 NPI rules and
    input data has NM108 element but NM109 element is not present.
    

Problem conclusion

  • hcsvu library rule type 72 updated to properly check for null
    NM109 before running the check digit logic to validate NPI
    format.
    
    Applies to:
    Healthcare Pack HIPAA 10.1.0, 10.2.0, 10.2.1, 10.2.2.
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next fix pack or product release is available,
    check the IBM Transformation Extender product Release Notes
    page:
    https://www.ibm.com/support/pages/node/318755
    
    If a fix pack release is available, download it from Fix
    Central:
    http://www.ibm.com/support/fixcentral/
    
    If a new product release is available, download it from Passport
    
    
    Advantage:
    https://www.ibm.com/software/passportadvantage/pao_customer.html
    
    
    
    
    If the fix pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    
    
    Interim Fix (LAIF) by opening a support Case:
    https://www.ibm.com/mysupport
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH60684

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-04-03

  • Closed date

    2024-10-01

  • Last modified date

    2024-11-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]

Document Information

Modified date:
05 November 2024