Subscribe to this APAR
By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.
APAR (Authorized Program Analysis Report) |
Abstract
LIC-INCORROUT FLASH COPIED UNITS MISSING FROM CONFIGURATION
Error Description
Disk units were missing from the configuration when the target
partition did an IPL
Problem Summary
Flash Copy target disk units were missing from the configuration
after the partition was IPLd
Problem Conclusion
The system licensed internal code is changed to add a Advanced
Analysis macro FIXFLASHSIZE to correct the configuration
problem.
Temporary Fix
Comments
Circumvention
PTFs Available
R730 MF66468 9311
R740 MF66471 9304
Affected Modules
Affected Publications
Summary Information
Status............................................ | CLOSED PER |
HIPER........................................... | No |
Component.................................. | 9400DG300 |
Failing Module.......................... | RCHMGR |
Reported Release................... | R730 |
Duplicate Of.............................. |
IBM i Support
IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information
Document Information
Modified date:
16 November 2019