Abstract

LIC-MEDIA-OPT-MSGOPT1345 WHEN EOV REACHED

Error Description

LIC-MEDIA-OPT-MSGOPT1345 WHEN EOV REACHED                      
                                                               
Save to optical may also fail with OPT1515. Vl3A001000,        
VL3A001005 & VL3A00100D are logged.                            

Problem Summary

When writing to an optical device, and the data is too large to
fit on a single volume, the operation may fail with            
MSGOPT1345(No free space available on media) or MSGOPT1183 (File
too fragmented) at the end of a volume instead of switching to  
and continuing on the next volume.                              

Problem Conclusion

The media was being unnecessarily fragmented during the write,  
so there was not always enough room left to commit the file    
directory to media. Apply this fix to prevent unnecessary      
fragmentation of the media.                                    

Temporary Fix

Comments

Circumvention


PTFs Available

R720 MF66291   9297
R730 MF66292   9311
R740 MF66293   9304

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 9400DG300
Failing Module.......................... RCHMGR
Reported Release................... R730
Duplicate Of..............................




IBM i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.1.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R2M0;V7R3M0;V7R4M0","Edition":"","Line of Business":{"code":"","label":""}}]