Abstract

LIC MSD IPL NOT SHUTTING DOWN COMPLETELY.

Error Description

If a system crashes when there is pending link loader work the  
following IPL will be a MSD IPL.  When this MSD IPL ends, the  
code that writes changed pages to dasd will fail, causing the  
next IPL to do additional processing during the SM recovery    
step.                                                          

Problem Summary

If a system crashes when there is pending link loader work the  
following IPL will be a MSD IPL.  When this MSD IPL ends, the  
code that writes changed pages to dasd will fail, causing the  
next IPL to do additional processing during the SM recovery    
step.                                                          

Problem Conclusion

The MSD IPL shutdown code is taking an exception and failing    
when it touches memory that has not been initialized since we  
performed a MSD IPL.  The code is changed to recognize the IPL  
type, and if it is a MSD IPL, limit the amount of memory it    
processes to only the memory that was initialized.              

Temporary Fix

Comments

Circumvention


PTFs Available

R720 MF99109 PTF Cover Letter   8249
R730 MF99204 PTF Cover Letter   8025

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 9400DG300
Failing Module.......................... RCHMGR
Reported Release................... R720
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB08","label":"Cognitive Systems"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.3.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R2M0;V7R3M0","Edition":"","Line of Business":{"code":"","label":""}}]