LIC-DISK-OTHER-SRC19B07001-INCORROUT-DISK-D/TDISK

Error Description

Disk PFA error on Light Path systems and attached enclosures may
not be called home due to intermittent problem.                
5887 FRU fault LED remains on after a DASD repair.              

Problem Summary

****************************************************************
* PROBLEM: (MA45554) Licensed Program = 5770999 for i 7.1,     *
*                                       i 7.2, and i 7.3       *
*           Base System Function- Work Management, Install, PTF*
*            System may fail to call home predictive failure   *
*            failure error logs.                               *
****************************************************************
* USERS AFFECTED: All IBM i operating system users.            *
****************************************************************
* RECOMMENDATION: Apply LIC PTF MF61905 for i 7.1.             *
*                 Apply LIC PTF MF61906 for i 7.2.             *
*                 Apply LIC PTF MF61908 for i 7.3.             *
****************************************************************
********                                                        
Disk PFA error on Light Path systems and attached enclosures may
not be called home due to intermittent problem.                
This PTF also incorporates a change to the Service Action Log  
function for deactivating a 5887 FRU fault LED (including DASD)
called out in the SAL details screen.  If the state of the LED  
shows as "OFF" in the SAL screen the user can still select the  
option "5=FAULT OFF" and SAL will issue the command to turn the
fault LED off.  Without this PTF the SAL screen will not attempt
to turn off a fault LED if the screen shows that the LED is    
already off.  This change is a work around for a known problem  
determining the state of the fault LED.  The SAL change only    
applies to system models that activate FRU fault LEDs (Light    
Path systems).  System models that do not activate FRU fault    
LEDs (Guiding Light systems) do not provide the "5=FAULT OFF"  
option on the SAL screen.                                      

Problem Conclusion

Apply PTF                                                      

Temporary Fix

                       *********                                
                       * HIPER *                                
                       *********                                

Comments

Circumvention


PTFs Available

R710 MF61905 PTF Cover Letter   6320
R720 MF61906 PTF Cover Letter   6306
R730 MF61908 PTF Cover Letter   6299

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... Yes
Component.................................. 9400DG300
Failing Module.......................... RCHMGR
Reported Release................... R710
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.3.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0;V7R2M0;V7R3M0","Edition":"","Line of Business":{"code":"","label":""}}]