MA40025 - OSP-COMM-TCPIP-ACT-RC3448 MSGCPIB683 NETSERVER UNABLE TO START
UNTIL AFTER AN IPV4 INTERFACE HAS STARTED.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 APAR (Authorized Program Analysis Report)

Abstract

OSP-COMM-TCPIP-ACT-RC3448 MSGCPIB683 NETSERVER UNABLE TO START
UNTIL AFTER AN IPV4 INTERFACE HAS STARTED.

Error Description

System i NetServer unable to start until after an IPv4          
interface has started.                                          
On systems starting only an IPv6 interface, QSYSOPR message    
queue or QHST will contain:                                    
MSGCPIB683 RC=5 - Start of the NetBIOS over TCP/IP failed with  
return code 3448.                                              
3448 maps to CPE3448 "The protocol required to support the      
specified address family is not available at this time."        

Problem Summary

Please see the ERROR DESCRIPTION section.                      

Problem Conclusion

NetBIOS is only supported over IPv4 which is why EUNATCH is    
returned when starting NetBIOS with only IPv6 interfaces active.
NetBIOS is not supported over IPv6; however, it has been updated
to allow limited start-up to occur if only IPv6 interfaces are  
active.                                                        

Temporary Fix

Comments

CPIB683                                                        

Circumvention


PTFs Available

R710 MF51263 PTF Cover Letter   1116

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 9400DG300
Failing Module.......................... RCHMGR
Reported Release................... R710
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.1.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0","Edition":"","Line of Business":{"code":"","label":""}}]