Error description

  • When an appliance user performed power source maintenance work,
    the MQ appliance model M2001 (machine type 8436-55X) alert LED
    in the front panel was illuminated. "show ipmi-sel" showed the
    PSU1 or PSU2 had "Output Failure" , but related PSU's LED was
    green, which means that PSU was still in the normal state and
    working good.
    
    The recreate procedure:
    
    - Target unit: MQ Appliance M2001
    - Make sure two PSUs are in the good state.
    - Make sure the Alert LED is OFF.
    - Make sure IPMI-SEL does not have any "output failure" events
    for PSUs.
    - Steps:
      - Remove the power cable for PSU-1, wait 2 seconds, and
    connect the power cable.
      - Check the PSU LED, it should be solid GREEN.
      - Check the Alert LED, it should be ON.
      - Login DP CLI, issues "show sensors-other", the result is:
    
    idg(config)# show sensors-other
    
     Name                          Value Status
     ----------------------------- ----- -------
     Intrusion Detected            false ok
     Power Supply 1 AC Lost        false ok
     Power Supply 1 Output Failure true  failure
     Power Supply 2 AC Lost        false ok
     Power Supply 2 Output Failure false ok
    
    
      - Issue "show ipmi-sel",  you should get
    "powerSupplyFailureDetected" event for PSU-1:
     111   2020/03/13 12:21:34      0x0002      systemEvent
    0x0000                       timestampClockSync         none
            asserted
     112   2020/03/23 06:46:12      0x0002      powerSupply
    0x002E        PSU_1-Status   powerSupplyFailureDetected none
            asserted
     113   90 seconds uptime        0x0002      systemEvent
    0x0000                       timestampClockSync         none
            asserted
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of MQ appliance M2001 models
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    MQ appliance firmware needs to be updated to upgrade the M2001
    BMC version to v1.32 to fix the following problems.
    
    - When removing the power cable and reconnecting it within 6
    seconds,
    it cause the VIN_UV_FAUL bit is ON.
    - This VIN_UV_FAUL bit means the outside power source has
    problem, not
    a problem in the PSU itself, which means the PSU itself is OK.
    - The reason for this bit ON is due to PSU has a capacitor, if
    removing and connecting the power cable within 6 seconds, there
    are
    still some  power in the capacitor, so that this bit is ON,
    instead of AC Lost event.
    - If removing the connecting the power cable > 6 seconds, due
      to the capacitor
    released all power, the AC Lost event occurs.
    - This new BMC v1.32 is to ignore the VIN_UV_FAUL monitoring,
    since it only  means the outside power source's problem, not the
    PSU.
    

Problem conclusion

  • MQ appliance has been updated to upgrade the M2001 BMC version
    v1.32.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v9.1 CD    TBC.
    v9.1 LTS   9.1.0.6
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT32320

  • Reported component name

    MQ APPLIANCE M2

  • Reported component ID

    5737H4700

  • Reported release

    910

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-03-26

  • Closed date

    2020-05-01

  • Last modified date

    2020-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MQ APPLIANCE M2

  • Fixed component ID

    5737H4700

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS5K6E","label":"IBM MQ Appliance"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date:
02 May 2020