APAR status
Closed as program error.
Error description
The following warning message is printed in MSGLOG: 14:57:51 DR: Warning: The table minversion DBA feature is enabled on this secondary (flag with value 0x400000 of the SQL_DEF_CTRL onconfig parameter). Please ensure that this feature is also enabled on the connected primary server, otherwise the secondary server may not behave as expected when table minversion changes occur! This message is printed even when the SQL_DEF_CTRL feature is not in ONCONFIG, as it's starting with defaults setting (Also printed in online.log) at startup. 14:57:43 CCFLAGS2 value set to 0x200 14:57:43 SQL_FEAT_CTRL value set to 0x8008 14:57:43 SQL_DEF_CTRL value set to 0x4004b0 14:57:43 IBM Informix Dynamic Server Version 12.10.FC13WE Software Serial Number AAA#B000000
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC15 and 14.10.xC5. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC15 or 14.10.xC5. * ****************************************************************
Problem conclusion
Fixed in Informix Server 12.10.xC15 and 14.10.xC5.
Temporary fix
Comments
APAR Information
APAR number
IT30689
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-10-23
Closed date
2020-10-07
Last modified date
2020-10-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10"}]
Document Information
Modified date: