Direct links to fixes
8.1.0-TIV-NCOMNIbus-ZLinux-FP0030
8.1.0-TIV-NCOMNIbus-Windows-FP0030
8.1.0-TIV-NCOMNIbus-Linux-FP0030
8.1.0-TIV-NCOMNIbus-AIX-FP0030
8.1.0-TIV-NCOMNIbus-ZLinux-FP0029
8.1.0-TIV-NCOMNIbus-Windows-FP0029
8.1.0-TIV-NCOMNIbus-Linux-FP0029
8.1.0-TIV-NCOMNIbus-AIX-FP0029
8.1.0-TIV-NCOMNIbus-ZLinux-FP0028
8.1.0-TIV-NCOMNIbus-Windows-FP0028
8.1.0-TIV-NCOMNIbus-Linux-FP0028
8.1.0-TIV-NCOMNIbus-AIX-FP0028
8.1.0-TIV-NCOMNIbus-ZLinux-FP0026
8.1.0-TIV-NCOMNIbus-Windows-FP0026
8.1.0-TIV-NCOMNIbus-Linux-FP0026
8.1.0-TIV-NCOMNIbus-AIX-FP0026
8.1.0-TIV-NCOMNIbus-ZLinux-FP0024
8.1.0-TIV-NCOMNIbus-Windows-FP0024
8.1.0-TIV-NCOMNIbus-Linux-FP0024
8.1.0-TIV-NCOMNIbus-AIX-FP0024
8.1.0-TIV-NCOMNIbus-ZLinux-FP0023
8.1.0-TIV-NCOMNIbus-Windows-FP0023
8.1.0-TIV-NCOMNIbus-Linux-FP0023
8.1.0-TIV-NCOMNIbus-AIX-FP0023
Tivoli Netcool/OMNIbus 8.1.0 Fix Pack 23, 8.1.0-TIV-NCOMNIbus-FP0023
Tivoli Netcool/OMNIbus 8.1.0 Fix Pack 24, 8.1.0-TIV-NCOMNIbus-FP0024
Tivoli Netcool/OMNIbus 8.1.0 Fix Pack 26, 8.1.0-TIV-NCOMNIbus-FP0026
Tivoli Netcool/OMNIbus 8.1.0 Fix Pack 25, 8.1.0-TIV-NCOMNIbus-FP0025
Tivoli Netcool/OMNIbus 8.1.0 Fix Pack 27, 8.1.0-TIV-NCOMNIbus-FP0027
Tivoli Netcool/OMNIbus 8.1.0 Fix Pack 28, 8.1.0-TIV-NCOMNIbus-FP0028
Tivoli Netcool/OMNIbus 8.1.0 Fix Pack 29, 8.1.0-TIV-NCOMNIbus-FP0029
APAR status
Closed as program error.
Error description
The new generic property Props.LiveUpdate was introduced in 8.1 fixpack 22 (APAR IJ21246). When this property is set to TRUE, and an update to the props file is detected, the file is reread and processed at runtime without the need to stop/restart a component. The ObjectServer already supports property updates via the SQL 'ALTER SYSTEM SET' command. Any property update via this command should always take precedence over any manual props file updates. Even though we would not recommend it, it should be possible to update one property via the props file whilst another using the SQL command, without the one update interfering with the other. Only properties that can also be updated via 'ALTER SYSTEM SET' command should become effective if the update is attempted via the propsfile. (Many ObjectServer properties are READONLY)
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: * * Users that use the ObjectServer SQL 'ALTER SYSTEM SET' * * command to update an ObjectServer property on an * * ObjectServer that has Props.LiveUpdate set to 'TRUE'. * **************************************************************** * PROBLEM DESCRIPTION: * * With Props.LiveUpdate set to 'TRUE', and a property was * * updated and reread from the props file, the value of the * * property was not also updated in the catalog.properties * * table. The easiest way to test this is to execute a V3 style * * command: get prop '<propname>'. * **************************************************************** * RECOMMENDATION: * * Apply the maintenance vehicles listed in the Problem * * Conclusion. * ****************************************************************
Problem conclusion
The fix for this APAR is contained in the following maintenance package: | fix pack | 8.1.0-TIV-NCOMNIbus-FP0023
Temporary fix
Comments
APAR Information
APAR number
IJ22958
Reported component name
NETCOOL/OMNIBUS
Reported component ID
5724O4800
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-02-25
Closed date
2020-04-30
Last modified date
2020-04-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
NETCOOL/OMNIBUS
Fixed component ID
5724O4800
Applicable component levels
Document Information
Modified date:
17 March 2023