z/OS DFSMSrmm Diagnosis Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


F13

z/OS DFSMSrmm Diagnosis Guide
SC23-6876-00

Explanation

At OPEN time for tape data sets, DFSMSrmm fails to update the DFSMSrmm control data set with information about tape usage or the operator mounted a volume that is not acceptable to DFSMSrmm. DFSMSrmm issues an error message describing the reason why the volume cannot be used.

DFSMSrmm issues this code for one of these reasons:
  • An error occurred performing I/O to the DFSMSrmm control data set and the operator replied CANCEL to message EDG4001D.
  • The DFSMSrmm journal file is locked and the operator replied CANCEL to message EDG4000D.
  • The DFSMSrmm subsystem is not active and the operator replied CANCEL to message EDG4012D.
  • The current volume was not acceptable to DFSMSrmm, and DFSMSrmm could find no other acceptable volume.

If DFSMSrmm returns a reason code or user completion code, this is an indication that a DFSMSrmm subsystem routine failed.

System action

The current OPEN request fails because no volume is available to satisfy the request.

Operator response

None.

Programmer response

When DFSMSrmm issues message EDG4000D or EDG4001D, refer to the suggested actions for the messages. When DFSMSrmm issues message EDG4012D, ensure that the DFRMM procedure is active and specify the correct volume and tape data set information for specific tape mount request.

Module

EDGOCEOV, EDGOCEXT, EDGOECM

F14

Explanation

DFSMSrmm fails to update the DFSMSrmm control data set with information about tape usage because the DFSMSrmm subsystem is not active. DFSMSrmm issues an error message to describe the problem. If a reason code or user completion code is provided, this is an indication that the DFSMSrmm subsystem routine failed.

System action

The CLOSE or End-Of-Volume processing fails. Processing depends on the application error recovery processing.

Operator response

Refer to the action described for the associated error message.

System programmer response

Refer to the action described for the associated error message.

Module

EDGOCEOV, EDGOCEXT

F37

Explanation

An error occurred during validation of a tape volume, or during updating of the DFSMSrmm control data set. DFSMSrmm issues an error message describing the error. DFSMSrmm issues F37 at End-Of-Volume, when validating the new volume for a multivolume tape data set or when recording the use of the previous volume.

DFSMSrmm issues F37 for one of these reasons:
  • An error occurred performing I/O to the DFSMSrmm control data set and the operator replied CANCEL to message EDG4001D.
  • The DFSMSrmm journal file is locked and the operator replied CANCEL to message EDG4000D.
  • The DFSMSrmm subsystem is not active and the operator replied CANCEL to message EDG4012D.
  • The current volume was not acceptable to DFSMSrmm and DFSMSrmm could find no other acceptable volume.

If a reason code or user completion code is provided, this indicates that the DFSMSrmm subsystem routine failed. DFSMSrmm issues this code because either the DFSMSrmm subsystem is not active and the operator replied CANCEL to message EDG4012D or because the current volume was not acceptable to DFSMSrmm and DFSMSrmm could find no other acceptable volume.

System action

The current EOV request fails.

Operator response

None.

Programmer response

When DFSMSrmm issues message EDG4000D or EDG4001D, refer to the suggested actions described for the messages. When DFSMSrmm issues message EDG4012D, ensure that the DFRMM procedure is active and specify the correct volume and tape data set information for specific tape mount requests. If a tape volume is rejected because it violates DFSMSrmm tape usage rules, correct your JCL and rerun the job.

Module

EDGOCEOV, EDGOECM