Error
Unexpected return code or incorrect output when using the list and execute form of a macro. Results are not the same as for standard form.
Action
  1. Check that the list form is in a CSECT, not a DSECT. If the list form is only in a DSECT, the parameter list will not be initialized.
  2. Check that the list form was copied over correctly into the GETMAIN work area.
  3. Make sure the LIST and EXECUTE forms of the RACROUTE macro specify the same value for the RELEASE= parameter.
Error
Incorrect output from a macro with some keywords that were ignored.
Action
If the macro is continued on a second line, check that there is a continuation marked in column 72 and that the second line begins in column 16. If the macro is continued in column 17 or later, the assembler will ignore that line.