- Error
- Unexpected return code or incorrect output when using the list
and execute form of a macro. Results are not the same as for standard
form.
- Action
- Check that the list form is in a CSECT, not a DSECT. If the list
form is only in a DSECT, the parameter list will not be initialized.
- Check that the list form was copied over correctly into the GETMAIN
work area.
- Make sure the LIST and EXECUTE forms of the RACROUTE macro specify
the same value for the RELEASE= parameter.
- Error
- Incorrect output from a macro with some keywords that were ignored.
- Action
- If the macro is continued on a second line, check that there
is a continuation marked in column 72 and that the second line begins
in column 16. If the macro is continued in column 17 or later, the
assembler will ignore that line.
|