z/OS Infoprint Server Messages and Diagnosis
Previous topic | Next topic | Contents | Index | Contact z/OS | Library | PDF


System abend code and reason codes

z/OS Infoprint Server Messages and Diagnosis
GA32-0927-00

System abend code and reason codes

The system abend code for abends that NetSpool displays is 8C3.

NetSpool does not attempt to restart after an abend. NetSpool displays a reason code for each abend. Reason codes are listed in Table 2.

In the event of an abend, you should capture the dump, save the abend information from the operator console, and report the error to the IBM® Support Center.

Table 2. NetSpool abend reason codes
Abend reason codeMeaning
X'0500'Unable to get storage
X'0501'Problem with Printer Inventory
X'0502'Attach of subtask failed
X'0503'Latch service failed
X'0504'VTAM® problem
X'0505'Select logic error
X'0506'Modeset failed
X'0507'Initial building of printer definition block failed
X'0508'Initial building of LU block failed
X'0509'Incorrect function code in event block
X'0510'Incorrect display function code
X'0511'Incorrect LU type in session block
X'0512'Incorrect PLU type in EOF rules
X'0513'Incorrect object type in event block
X'0514'Incorrect object type specified in parameter list when building printer definition block
X'0515'Unable to find printer definition block to be deleted
X'0516'SCS page format is not valid. It does not start with 2BC1 or 2BC2
X'0517'Cannot load CEEPIPI
X'0518'CEEPIPI isub failed
X'0519'CEEPIPI call failed
X'0520'CEEPIPI delete failed
X'0521'iconv open failed
X'0522'iconv conv failed
X'0523'iconv close failed
X'0524'Dubthread failed
X'0525'Dubprocess failed
X'0526'Logic error during PCL conversion
X'0527'Logic error during line data conversion
X'0528'UNIX SELECT/SELECTEX error

Go to the previous page Go to the next page