IBM Print Transforms from AFP for Infoprint Server for z/OS
Previous topic | Next topic | Contents | Index | Contact z/OS | Library | PDF


Example -- ISPF Processing panel for the AFP to PostScript transform

IBM Print Transforms from AFP for Infoprint Server for z/OS
G325-2634-02

Example -- ISPF Processing panel for the AFP to PostScript transform

Figure 7 shows the ISPF panel that you use to specify the AFP to PostScript transform in a printer definition. Only a portion of the Processing panel is shown. This example uses the afpxps_eu transform class from the aopxfd.conf file.

Figure 7. Example of the ISPF Processing panel for the AFP to PostScript transform
Edit                                 Processing
Command ==> ____________________________________________________________

Printer definition name . postscript1      

·
·
·
Supported data formats and associated filters: Data format: Filter: / Line data afpxps.dll -c eu %filter-options (extend) / MO:DCA-P afpxps.dll -c eu %filter-options (extend) / PostScript _______________________________________________________ (extend) / Text aopfiltr.so (extend) _ PCL _______________________________________________________ (extend) _ PDF _______________________________________________________ (extend) _ SAP _______________________________________________________ (extend) / XML afpxps.dll -c eu %filter-options (extend) _ TIFF _______________________________________________________ (extend) _ JPEG _______________________________________________________ (extend) _ Other _______________________________________________________ (extend) / Resubmit for filtering
·
·
·
Transforms: Fail on error . . . . 2 1. No 2. Error 3. Warning Trailer error page. . 1 1. No 2. Error 3. Warning
·
·
·

Explanation of fields:

  • The Line data, MO:DCA-P, and XML data formats are selected because the afpxps.dll filter can transform these data formats to PostScript format. The transform options are:
    • The -c filter option causes the transform to use the eu transform class, which is defined in the transform configuration file.
    • The %filter-options filter option lets the job submitter override the transform class because it is specified to the right of the -c filter option.
  • The Text and PostScript data formats are selected because the printer can accept these data formats. The aopfiltr.so filter is specified for Text data because Print Interface uses this filter.
  • The Resubmit for filtering field is selected so that IP PrintWay™ basic mode calls Print Interface to transform documents submitted from batch applications.
  • In the Fail on error field, option Error is selected. If a data stream error occurs during the transform, the transform fails and does not create an output document.
  • In the Trailer error page field, option No is selected. The transform does not write any warning or error messages to a trailer error page.

Go to the previous page Go to the next page