BPXI074I LOAD LIBRARY loadlib IS NOT ON THE SPECIFIED VOLUME voln

Explanation

While processing SETOMVS, SET OMVS, F OMVS,RESTART, or OMVS initialization, the system encountered a SERV_LPALIB or SERV_LINKLIB parameter in the BPXPRMxx parmlib member which referenced a load library name that is not on the specified volume.

In the message text:
LOAD LIBRARY loadlib
loadlib is the name of the load library that the system could not find.
VOLUME voln
voln is the number of the volume where the system expected to find the load library.

System action

SETOMVS, SET OMVS, F OMVS,RESTART or OMVS Initialization processing fails.

System programmer response

Do one of the following, as appropriate, to correct the problem:
  • If the system issued this message system during initialization or during F OMVS,RESTART command processing, respecify a corrected BPXPRMxx parmlib member.
  • Correct the SERV_LPALIB or SERV_LINKLIB BPXPRMxx parmlib keyword in error and then retry the SETOMVS or SET OMVS command.

Module

BPXIPMZ1

Source

z/OS UNIX System Services kernel (BPX)

Routing Code

-

Descriptor Code

4