PSI_LNK

The path to the service processor might be the failing item.

  1. Are there any B1xxxxxx system reference codes in the serviceable event view that were logged at approximately the same time as this error?
    • Yes: Close this problem and resolve the B1xxxxxx system reference codes. This ends the procedure.
    • No: Continue with the next step.
  2. Use the following table to determine the failing items. Replace the failing items in the order that they are listed until the problem is resolved. If the problem is not resolved by replacing the failing items, contact your next level of support.
    Type and model Failing items
    5148-21L, 5148-22L, 8247-21L, 8247-22L, 8247-42L, 8284-21A, 8284-22A, 8286-41A, or 8286-42A

    BACKPLN

    ANYPROC

    8408-44E or 8408-E8E

    SVCPROC

    BACKPLN

    ANYPROC

    9080-MHE, 9080-MME, 9119-MHE, or 9119-MME

    SPCABLE

    GFSPCRD and SVCPROC
    Note: Replace the failing items indicated by GFSPCRD and SVCPROC at the same time.

    ANYPROC

    BACKPLN

    NODEPL

    This ends the procedure.