Step 1: Configuring the IODF
This example shows how to configure two ports of a FICON® or FICON Express feature for FCP.
Procedure
- Define two FCP CHPIDs. Both are given the number 50, one
for channel subsystem 0 and one for channel subsystem 1:
CHPID PATH=(CSS(0),50),SHARED, * PARTITION=((LP01,LP02,LP03,LP04,LP05,LP06,LP07,LP08,LP09* ,LP10,LP11,LP12,LP13,LP14,LP15),(=)),PCHID=160,TYPE=FCP CHPID PATH=(CSS(1),50),SHARED, * PARTITION=((LP16,LP17,LP18,LP19,LP20,LP21,LP22,LP23,LP24* ,LP25,LP26,LP27,LP28,LP29,LP30),(=)),PCHID=161,TYPE=FCP - Assign FCP control unit 5402 to the new CHPIDs:
CNTLUNIT CUNUMBR=5402,PATH=((CSS(0),50),(CSS(1),50)),UNIT=FCP
- Define several FCP devices starting
with device number 5400:
IODEVICE ADDRESS=(5400,002),CUNUMBR=(5402), * PARTITION=((CSS(0),LP01),(CSS(1),LP16)),UNIT=FCP IODEVICE ADDRESS=(5402,002),CUNUMBR=(5402), * PARTITION=((CSS(0),LP02),(CSS(1),LP17)),UNIT=FCP … IODEVICE ADDRESS=(5460,144),CUNUMBR=(5402), * PARTITION=((CSS(0),LP15),(CSS(1),LP30)),UNIT=FCP