Error event IDs and error codes
Error codes describe a service procedure that must be followed. Each event ID that requires service has an associated error code.
Note: Service procedures that involve field-replaceable units (FRUs) do not apply to software-based
products, such as IBM Spectrum Virtualize for Public Cloud. For
information about possible user actions that relate to FRU replacements, refer to your hardware
manufacturer documentation.
Error codes can be either notification type E (error) or notification type W (warning). 08 lists the event IDs that have corresponding error codes, and shows the error code, the notification type, and the condition for each event. For a list of informational events, which have no associated error codes, see Informational events.
The 07nnnn event ID range refers to node errors that were logged by the system. The last 3 digits represent the error that was reported by the node. You can find these codes in the error code reference.
Event ID | Notification type | Condition | Error code |
---|---|---|---|
009012 | W | DNS server failure. DNS server cannot be reached over the network by the cluster. | 1585 |
009020 | E | A system recovery has run. All configuration commands are blocked. | 1001 |
009040 | E | The error event log is full. | 1002 |
009052 | W | The following causes are possible: |
1196 |
009053 | E | A node has been missing for 30 minutes. | 1195 |
009054 | W | Node has been shut down. | 1707 |
009100 | W | The software install process has failed. | 2010 |
009101 | W | Software install package cannot be delivered to all nodes. | 2010 |
009110 | Software install process stalled due to lack of redundancy. | 2010 | |
009115 | Software downgrade process stalled due to lack of redundancy. | 2008 | |
009150 | W | Unable to connect to the SMTP (email) server. | 2600 |
009151 | W | Unable to send mail through the SMTP (email) server. | 2601 |
009153 | W | The system did not send an email. | 2601 |
009170 | W | Remote Copy feature capacity is not set. | 3030 |
009171 | W | The FlashCopy® feature capacity is not set. | 3031 |
009172 | W | The Virtualization feature has exceeded the amount that is licensed. | 3032 |
009173 | W | The FlashCopy feature has exceeded the amount that is licensed. | 3032 |
009174 | W | Remote Copy feature license limit exceeded. | 3032 |
009175 | W | Thin-provisioned volume usage not licensed. | 3033 |
009176 | W | The value set for the virtualization feature capacity is not valid. | 3029 |
009177 | E | A physical disk FlashCopy feature license is required. | 3035 |
009178 | E | A physical disk Metro Mirror and Global Mirror feature license is required. | 3036 |
009179 | E | A virtualization feature license is required. | 3025 |
009180 | E | Automatic recovery of offline node failed. | 1194 |
009181 | W | Unable to send email to any of the configured email servers. | 3081 |
009182 | W | The external virtualization feature license limit was exceeded. | 3032 |
009183 | W | Unable to connect to LDAP server. | 2251 |
009184 | W | The LDAP configuration is not valid. | 2250 |
009185 | E | The limit for the compression feature license was exceeded. | 3032 |
009186 | E | The limit for the compression feature license was exceeded. | 3032 |
009187 | E | Unable to connect to LDAP server that has been automatically configured. | 2256 |
009188 | E | Invalid LDAP configuration for automatically configured server. | 2255 |
009189 | W | A licensable feature's trial-timer has reached 0. The feature has now been deactivated. | 3082 |
009190 | W | A trial of a licensable feature will expire in 5 days. | 3083 |
009191 | W | A trial of a licensable feature will expire in 10 days. | 3084 |
009192 | W | A trial of a licensable feature will expire in 15 days. | 3085 |
009193 | W | A trial of a licensable feature will expire in 45 days. | 3086 |
009194 | W | Easy Tier® feature license limit exceeded. | 3032 |
009195 | W | FlashCopy feature license limit exceeded. | 3032 |
009196 | W | External virtualization feature license limit exceeded. | 3032 |
009197 | W | Remote copy feature license limit exceeded. | 3032 |
009198 | W | System update completion is required. | 2050 |
009199 | W | System update completion has stalled. | 2012 |
009200 | W | Encryption feature license limit exceeded. | 3032 |
009201 | W | The quorum application is out of date and must be redeployed. | 3123 |
009202 | W | System SSL certificate will expire within the next 30 days. | 3130 |
009203 | W | System SSL certificate has expired. | 2258 |
009205 | W | No active quorum device found on this cluster. | 3124 |
009207 | W | The quorum application is not storing system data correctly. | 3127 |
009208 | W | Local user passwords must be changed. | 3310 |
009209 | W | The LDAP administrator password must be changed. | 3320 |
009210 | W | The superuser password must be changed. | 3330 |
009216 | W | Object available threshold has been reached. | 3040 |
010002 | E | The node ran out of base event sources. As a result, the node has stopped and exited the system. | 2030 |
010003 | W | The number of device logins has reduced. | 1630 |
010004 | W | Device excluded due to excessive errors on all Managed Disks. | 1640 |
010006 | E | Access beyond end of disk, or Managed Disk missing. | 2030 |
010008 | E | The block size is invalid, the capacity or LUN identity has changed during the managed disk initialization. | 1660 |
010010 | E | The managed disk is excluded because of excessive errors. | 1310 |
010011 | E | The remote port is excluded for a managed disk and node. | 1220 |
010012 | E | The local port is excluded. | 1210 |
010013 | E | The login is excluded. | 1230 |
010015 | E | Timeout due to non-responsive device. | 1340 |
010016 | E | Timeout due to lost command | 1340 |
010017 | E | A timeout has occurred as a result of excessive processing time. | 1340 |
010018 | E | An error recovery procedure has occurred. | 1370 |
010019 | E | A managed disk is reporting excessive errors. | 1310 |
010020 | E | The managed disk error count threshold has exceeded. | 1310 |
010021 | W | There are too many devices presented to the system. | 1200 |
010022 | W | There are too many managed disks presented to the system. | 1200 |
010023 | W | There are too many LUNs presented to a node. | 1200 |
010024 | W | There are too many drives presented to a system. | 1200 |
010025 | W | A disk I/O medium error has occurred. | 1320 |
010026 | W | A suitable MDisk or drive for use as a quorum disk was not found. | 1330 |
010027 | W | The quorum disk is not available. | 1335 |
010028 | W | A controller configuration is not supported. | 1625 |
010029 | E | A login transport fault has occurred. | 1360 |
010030 | E | A managed disk error recovery procedure (ERP) has occurred. The node or
controller reported the following: |
1370 |
010031 | E | One or more MDisks on a controller are degraded. | 1623 |
010032 | W | The controller configuration limits failover. | 1625 |
010033 | E | The controller configuration uses the RDAC mode; this is not supported. | 1624 |
010034 | W | Persistent unsupported controller configuration. | 1695 |
010035 | W | Controller has quorum disabled, but quorum disk is configured. | 1570 |
010040 | E | The controller system device is only connected to the node through a single initiator port. | 1627 |
010041 | E | The controller system device is only connected to the node through a single target port. | 1627 |
010042 | E | The controller system device is only connected to the nodes through a single target port. | 1627 |
010043 | E | The controller system device is only connected to the nodes through half of the expected target ports. | 1627 |
010044 | E | The controller system device has disconnected all target ports to the nodes. | 1627 |
010045 | W | Number of Device paths from the controller site allowed accessible nodes has reduced | 1630 |
010050 | W | Solid state drive failed and rebuild is required. | 1201 |
010051 | A Solid state drive is missing from the configuration | 1202 | |
010052 | E | Solid state drive offline as a result of a drive hardware error. | 1205 |
010053 | E | Solid state drive reporting PFA errors. | 1215 |
010055 | W | An unrecognized SAS device. | 1665 |
010056 | E | SAS error counts exceeded the warning thresholds. | 1216 |
010057 | E | SAS errors exceeded critical thresholds. | 1216 |
010064 | E | Timeout due to TTO IMMEDIATE. | 1340 |
010066 | W | Controller indicates that it does not support descriptor sense for LUNs that are greater than 2 TBs. | 1625 |
010067 | W | Too many enclosures were presented to a system. | 1200 |
010070 | W | Too many controller target ports were presented to the system. | 1200 |
010071 | W | Too many target ports were presented to the system from a single controller. | 1200 |
010098 | W | There are too many drives presented to a system. | 1200 |
010100 | W | Incorrect connection to a port was detected. | 1669 |
010101 | E | Too many long I/O operations to drive. | 1680 |
010102 | E | A drive is reported as continuously slow with contributing factors. | 1680 |
010103 | E | Too many long I/O operations to drive (Mercury drives). | 1680 |
010104 | E | A drive is reported as continuously slow because of multiple factors (Mercury drives). | 1680 |
010105 | W | Storage system connected to unsupported port. | 2080 |
010106 | E | Drive reporting too many t10dif errors. | 1680 |
010107 | W | Encrypting MDisk is no longer encrypted. | 2580 |
010110 | W | Drive firmware download canceled because of system changes. | 3090 |
010111 | W | Drive firmware download canceled because of a drive download problem. | 3090 |
010117 | W | A disk controller is not accessible from a node allowed to access the device by site policy. | 1627 |
010118 | W | Too many drives attached to the system. | 1179 |
010119 | W | Drive data integrity error. | 1322 |
010120 | W | A member drive has been forced to turn off protection information support. | 2035 |
010121 | E | Drive exchange required. | 1693 |
010123 | W | Performance of external MDisk has changed. | 2115 |
010124 | W | iSCSI session excluded. | 1230 |
010125 | W | A flash drive is expected to fail because its write endurance value exceeds 95. | 1215 |
010126 | W | The usage rate for a flash drive is high, which can affect the expected lifespan of the drive. | 2560 |
010128 | W | Drive erase operation is corrupted. | 3340 |
020001 | E | There are too many medium errors on the MDisk. | 1610 |
020002 | E | A storage pool is offline. | 1620 |
020003 | W | There are insufficient virtual extents. | 2030 |
020008 | E | Storage optimization services disabled. | 3023 |
020009 | E | Compressed array running low on physical space. | 1246 |
020010 | E | Critical level of compressed array running low on physical space. | 1246 |
020011 | E | 1% physical space left for compressed array. | 1242 |
020012 | E | Compressed array out of physical space. | 1241 |
020013 | W | EasyTier is set to active mode in pool with unsupported configuration, this may result in reduced performance. | 1846 |
020014 | W | EasyTier is set to measure mode due to unsupported configuration in pool. | 1845 |
020015 | W | Easy Tier cannot optimize data placement because there is not enough available capacity in the pool. | 1878 |
020017 | W | Easy Tier protection limit exceeded on an overprovisioned managed disk. | 1915 |
029001 | E | The MDisk has bad blocks. | 1840 |
029002 | W | The system failed to create a bad block because MDisk already has the maximum number of allowed bad blocks. | 1226 |
029003 | W | The system failed to create a bad block because the system already has the maximum number of allowed bad blocks. | 1225 |
030000 | W | FlashCopy prepare failed due to cache flush failure. | 1900 |
030010 | W | FlashCopy has been stopped due to the error indicated in the data. | 1910 |
030015 | W | The Volume Group Snapshot is degraded. | 1911 |
030016 | W | The Clone or Thin-Clone Volume is corrupt. | 1912 |
030020 | W | Unrecovered FlashCopy mappings. | 1895 |
030021 | W | Automated snapshot not collected at expected time. | 1913 |
045102 | W | SAS cable is not working at full capacity. | 1260 |
045103 | E | An attempt to automatically configure a reseated or replaced drive has failed. | 1686 |
045104 | W | Drives are single ported due to a spare node. | 3200 |
045105 | E | Enclosure secondary expander module has failed. | 1267 |
045106 | E | Enclosure secondary expander module FRU identity is not valid. | 1266 |
045107 | E | Enclosure secondary expander module temperature sensor cannot be read. | 1267 |
045108 | E | Enclosure secondary expander module temperature has passed warning threshold. | 1098 |
045109 | E | Enclosure secondary expander module temperature has passed critical threshold. | 1095 |
045110 | E | Enclosure display panel is not installed. | 1268 |
045111 | E | Enclosure display panel temperature sensor cannot be read. | 1268 |
045112 | E | Enclosure display panel temperature has passed warning threshold. | 0451101098 |
045113 | E | Enclosure display panel temperature has passed critical threshold. | 1095 |
045114 | E | Enclosure secondary expander module connector excluded due to too many change events. | 1267 |
045119 | E | Enclosure display panel VPD cannot be read. | 1268 |
045120 | E | Enclosure secondary expander module is missing. | 1267 |
045121 | E | Enclosure secondary expander module connector excluded due to dropped frames. | 1267 |
045122 | E | Enclosure secondary expander module connector is excluded and cannot be unexcluded. | 1267 |
045123 | E | Enclosure secondary expander module connectors excluded as the cause of single ported drives. | 1267 |
045124 | E | Enclosure secondary expander module leaf expander connector excluded as the cause of single ported drives. | 1267 |
045137 | E | Cannot communicate with the PSU. | 1123 |
045138 | W | PSU is not installed correctly. | 1127 |
045139 | E | Drive slot contains a device that is not responding. | 1686 |
045140 | W | Power supply unit has an invalid input voltage. | 1297 |
045141 | W | Power supply units are mismatched. | 1298 |
045142 | W | There are too many transient temperature events in the past 24 hours. | 1098 |
045143 | E | Canister has failed due to a secure boot failure. | 1063 |
045145 | E | Canister has a secure boot failure caused by the BIOS. | 1073 |
050001 | W | The Metro Mirror or Global Mirror relationship cannot be recovered. | 1700 |
050002 | W | A Metro Mirror or Global Mirror relationship or consistency group exists within a system, but its partnership is deleted. | 3080 |
050010 | W | A Global Mirror relationship has stopped because of a persistent I/O error. | 1920 |
050011 | W | A remote copy has stopped because of a persistent I/O error. | 1915 |
050020 | W | Remote Copy relationship or consistency groups lost synchronization. | 1720 |
050030 | W | There are too many system partnerships. The number of partnerships has been reduced. | 1710 |
050031 | W | There are too many system partnerships. The system has been excluded. | 1710 |
050040 | W | Background copy process for the remote copy was blocked. | 1960 |
050041 | W | Partner cluster IP address unreachable. | 2021 |
050042 | W | Cannot authenticate with partner cluster. | 2022 |
050043 | W | Unexpected cluster ID for partner cluster | 2023 |
050050 | E | The Global Mirror secondary volume is offline. The relationship has pinned hardened write data for this volume. | 1925 |
050060 | E | The Global Mirror secondary volume is offline due to missing I/O group partner node. The relationship has pinned hardened write data for this volume but the node containing the required data is currently offline. | 1730 |
050070 | E | Global Mirror performance is likely to be impacted. A large amount of pinned data for the offline volumes has reduced the resource available to the global mirror secondary disks. | 1925 |
050080 | W | HyperSwap® volume has lost synchronization between sites. | 1940 |
050081 | W | HyperSwap consistency group has lost synchronization between sites. | 1940 |
050082 | E | Compression has stopped unexpectedly. | 3131 |
050090 | W | The system cannot compress data being sent to the remote system in an IP partnership due to local system limitations. | 3131 |
050091 | W | The system cannot compress data being sent to the remote system in an IP partnership due to remote system limitations. | 3145 |
050092 | W | The system has stopped compressing data that is being sent to a remote system in an IP partnership due to bandwidth limits. | 3150 |
Remote command failure during replicated volumegroup configuration. | |||
060001 | W | A thin-provisioned volume copy is offline because of insufficient space. | 1865 |
060002 | E | A thin-provisioned volume copy is offline because of corrupt metadata. | 1862 |
060003 | E | A thin-provisioned volume copy is offline because of a failed repair. | 1860 |
060004 | W | A compressed volume copy is offline because of insufficient space. | 1865 |
060005 | E | A compressed volume copy is offline because of corrupt metadata. | 1862 |
060006 | E | A compressed volume copy is offline because of a failed repair. | 1860 |
060007 | E | A compressed volume copy has bad blocks. | 1850 |
060008 | W | Data reduction pool meta data corrupt. | 1862 |
060009 | W | The virtual disk copies for a pool are offline because the data reduction pool was not repaired. | 1860 |
060010 | W | The virtual disk copies for a pool are offline because of insufficient space on the data reduction pool. | 1865 |
060012 | W | Data reduction pool space warning. | 1867 |
062001 | W | System is unable to mirror medium error. | 1950 |
062002 | E | Mirrored volume is offline because it cannot synchronize data. | 1870 |
062003 | W | Repair of a mirrored volume stopped because of difference. | 1600 |
064001 | W | A host port has more than four logins to a node. | 2016 |
064002 | W | Host and Fibre Channel port must be in same portset. | 3454 |
070000 | E | Unrecognized node error. | 1083 |
070510 | E | Detected memory size does not match the expected memory size. | 1022 |
070511 | E | DIMMs are incorrectly installed. | 1009 |
070513 | E | Uncorrectable memory error was detected. | 1022 |
070517 | E | The WWNN that is stored on the service controller and the WWNN that is stored on the drive do not match. | 1192 |
070521 | E | Unable to detect any Fibre Channel adapter. | 1016 |
070522 | E | The system board processor has failed. | 1020 |
070523 | E | The internal disk file system of the node is damaged. | 1187 |
070524 | E | Unable to update BIOS settings. | 1027 |
070525 | E | Unable to update the service processor firmware for the system board. | 1020 |
070528 | E | The ambient temperature is too high while the system is starting. | 1182 |
070534 | E | System board fault. | 1026 |
070536 | E | A system board device breached critical temperature threshold. | 1084 |
070538 | E | A PCI Riser breached critical temperature threshold. | 1085 |
070541 | E | Multiple hardware failures. | 1184 |
070542 | E | The processor failed. | 1024 |
070543 | E | No usable persistent data was found on the boot drives. | 1035 |
070544 | E | The boot drives do not belong in this node. | 1035 |
070545 | E | Boot drive and system board do not match. | 1035 |
070547 | E | Pluggable TPM is missing or broken. | 1051 |
070548 | E | The node has compression hardware configured but no compression hardware is available. | 1046 |
070549 | E | The node's compression hardware failed. | 1046 |
070550 | W | Cannot form system due to lack of resources. | 1192 |
070551 | W | Cannot form cluster due to lack of cluster resources, overridequorum possible. | 1192 |
070556 | E | Duplicate WWNN detected on the SAN. | 1192 |
070558 | E | A node is unable to communicate with other nodes. | 1192 |
070562 | E | The node hardware does not meet minimum requirements. | 1183 |
070564 | E | Too many software failures. | 1188 |
070568 | E | Unable to upgrade adapter firmware. | 1469 |
070572 | E | Battery protection temporarily unavailable; both batteries are expected to be available soon. | 1473 |
070573 | E | Node software inconsistent. | 1192 |
070574 | E | The node software is damaged. | 1187 |
070576 | E | The system data cannot be read. | 1030 |
070578 | E | The system data was not saved when power was lost. | 1194 |
070580 | E | Unable to read the service controller ID. | 1192 |
070690 | W | Node held in service state. | 1189 |
070700 | W | Fibre Channel adapter missing. | 1045 |
070701 | E | Fibre Channel adapter failed. | 1046 |
070702 | E | Fibre Channel adapter PCI error. | 1046 |
070703 | E | Fibre Channel adapter degraded. | 1046 |
070704 | W | Fewer Fibre Channel ports operational. | 1060 |
070705 | W | Fewer Fibre Channel I/O ports operational. | 1450 |
070706 | W | Fibre Channel clustered system path failure. | 1550 |
070711 | E | SAS adapter failed. | 1046 |
070712 | E | SAS adapter PCI error. | 1046 |
070713 | E | SAS adapter degraded. | 1046 |
070715 | W | Fewer SAS ports operational. | 1046 |
070717 | W | SAS ports degraded. | 1046 |
070718 | W | SAS port connected to unsupported device. | 1669 |
070720 | W | Ethernet adapter missing. | 1045 |
070721 | E | Ethernet adapter failed. | 1046 |
070722 | E | Ethernet adapter PCI error. | 1046 |
070723 | E | Ethernet adapter degraded. | 1046 |
070724 | W | Fewer Ethernet ports. | 1046 |
070730 | Bus adapter missing. | 1192 | |
070731 | Bus adapter failed. | 1192 | |
070732 | Bus adapter PCI error. | 1192 | |
070733 | Bus adapter degraded. | 1192 | |
070734 | W71 | Inter-canister PCIe link not operational. | 1006 |
070747 | W | Technician connected. | 747 |
070760 | E | Voltage fault. | 1110 |
070761 | E | Voltage high. | 1100 |
070762 | E | Voltage low. | 1105 |
070765 | E | Service Processor shows fan failure. | 1089 |
070768 | W | Ambient temperature warning. | 1094 |
070769 | W | CPU temperature warning. | 1093 |
070770 | W | Shutdown temperature reached. | 1092 |
070830 | W | Encryption key required. | 1328 |
070831 | W | Encryption key invalid. | 2555 |
070832 | W | Encryption key not found. | 2555 |
070833 | W | USB device (such as hub) unsupported. | 2555 |
070836 | W | Encryption key required. | 1328 |
070842 | W | Fibre Channel IO port mapping failed. | 1059 |
070860 | W | Fibre-channel network fabric is too big. | 1800 |
071500 | W | Incorrect enclosure. | 1021 |
071501 | E | Incorrect slot. | 1192 |
071502 | E | No enclosure id and cannot get status from partner. | 1192 |
071503 | E | Incorrect enclosure type. | 1192 |
071504 | E | No enclosure id and partner matches. | 1192 |
071505 | E | No enclosure id and partner has cluster data that does not match. | 1192 |
071506 | E | No enclosure id and no cluster state on partner. | 1192 |
071507 | E | No enclosure id and no cluster state. | 1192 |
071508 | W | Cluster id different between enclosure and node. | 1023 |
071509 | E | Cannot read enclosure identity. | 1036 |
071510 | E | The detected memory size does not match the expected memory size. | 1032 |
071513 | E | Uncorrectable memory error was detected. | 1022 |
071522 | E | The system board processor has failed. | 1034 |
071523 | E | Internal disk file system is damaged. | 1187 |
071524 | E | Unable to update BIOS settings. | 1034 |
071525 | E | Unable to update system board service processor firmware. | 1034 |
071528 | W | Ambient temperature too high while system starting. | 1092 |
071535 | E | Canister internal PCIe switch failed. | 1034 |
071541 | E | Multiple hardware failures. | 1184 |
071542 | E | A processor failed. | 1024 |
071543 | E | No usable persistent data was found on the boot drives. | 1035 |
071545 | E | Boot drive and system board do not match. | 1035 |
071546 | E | Model ID mismatch between node and boot drive. | 1192 |
071547 | E | Pluggable TPM is missing or broken. | 1051 |
071548 | E | The node has compression hardware configured but no compression hardware is available. | 1046 |
071549 | E | The node's compression hardware failed. | 1046 |
071550 | W | Cannot form cluster due to lack of cluster resources. | 1192 |
071551 | W | Cannot form cluster due to lack of cluster resources, overridequorum possible. | 1192 |
071556 | W | Duplicate WWNN detected on SAN. | 1133 |
071562 | E | The node's hardware configuration does not meet minimum requirements. | 1034 |
071564 | W | Too many software failures. | 1188 |
071565 | E | The node's internal drive is failing. | 1032 |
071566 | E | The node's internal drive is failing. | 1030 |
071568 | E | Unable to upgrade adapter firmware. | 1469 |
071569 | E | CPU over temp. | 1032 |
071573 | E | Node software inconsistent. | 1187 |
071574 | E | Node software is damaged. | 1187 |
071576 | E | Cluster state and configuration data cannot be read | 1032 |
071578 | E | State data was not saved on power loss | 1194 |
071671 | W | The available battery charge is not enough to allow the node canister to start . Two batteries are charging. | 1176 |
071672 | W | The available battery charge is not enough to allow the node canister to start . One battery is charging. | 1176 |
071673 | E | The available battery charge is not enough to allow the node canister to start . No batteries are charging. | 1004 |
071690 | W | Node held in service state | 1189 |
071700 | W | Fibre Channel adapter missing | |
071701 | E | Fibre Channel adapter failed | |
071702 | E | Fibre Channel adapter PCI error | |
071703 | E | Fibre Channel adapter degraded | |
071704 | W | Fewer Fibre Channel ports operational. | 1061 |
071705 | W | Fewer Fibre Channel I/O ports operational. | 1450 |
071706 | W | Fibre Channel clustered system path failure. | 1550 |
071710 | W | SAS adapter missing | |
071711 | E | SAS adapter failed | |
071712 | E | SAS adapter PCI error | |
071713 | E | SAS adapter degraded | |
071715 | W | Fewer SAS ports operational | 1034 |
071717 | W | SAS ports degraded. | 1034 |
071718 | W | SAS port connected to unsupported device. | 1669 |
071720 | W | Ethernet adapter missing | |
071721 | E | Ethernet adapter failed | |
071722 | E | Ethernet adapter PCI error. | |
071723 | E | Ethernet adapter degraded | |
071724 | W | Fewer Ethernet ports | 1401 |
071730 | W | Bus adapter missing | 1032 |
071731 | E | Bus adapter failed | 1032 |
071732 | E | Bus adapter PCI error | 1034 |
071733 | E | Bus adapter degraded. | 1034 |
071734 | W | Inter-canister PCIe link not operational. | 1006 |
071743 | E | Boot drive missing, out of sync, or failed. | 1213 |
071744 | E | A boot drive is in the wrong location. | 1214 |
071745 | E | Boot drive is in an unsupported slot. | 1472 |
071747 | W | Technician connected. | 747 |
071755 | E | The CPLD is degraded | 1032 |
071765 | E | Service Processor shows fan failure. | 1089 |
071768 | W | Ambient temperature warning | 1094 |
071769 | W | CPU temperature warning | 1093 |
071773 | E | Cannot communicate with the PSU. | |
071774 | E | PSU indicates an output failure. | 1126 |
071775 | E | PSU failed. | 1124 |
071776 | E | PSU has indicated input power failure. | 1138 |
071777 | E | PSU is not installed correctly. | 1127 |
071790 | E | The midplane has a non-fatal issue. | 1008 |
071810 | W | Battery cold | 1156 |
071782 | W | Battery hot. | 1157 |
071786 | E | Battery VPD checksum | 1154 |
071788 | E | One or more DIMM temperature sensors failed or cannot be read. | 1022 |
071789 | E | One or more canister temperature sensors failed or cannot be read. | 1032 |
071821 | E | Ambient temperature sensor fault | 1008 |
071830 | W | Encryption key required | 1328 |
071831 | W | Encryption key invalid | 2555 |
071832 | W | Encryption key not found | 2555 |
071833 | W | USB device (such as hub) unsupported | 2555 |
071836 | W | Encryption key required | 1328 |
071850 | W | Canister battery is nearing end of life | 1159 |
072500 | W | Incorrect enclosure. | 1021 |
072501 | E | Incorrect slot. | 1192 |
072502 | E | No enclosure id and cannot get status from partner. | 1192 |
072503 | E | Incorrect enclosure type. | 1192 |
072504 | E | Enclosure id and partner does not match. | 1192 |
072505 | E | No enclosure id and partner has cluster data that does not match. | 1192 |
072506 | E | No enclosure id and no cluster state on partner. | 1192 |
072507 | E | No enclosure id and no cluster state. | 1192 |
072508 | W | Cluster id is different between enclosure and node. | 1023 |
072509 | E | Cannot read enclosure identity. | 1036 |
072510 | E | The detected memory size does not match the expected memory size. | 1032 |
072522 | E | The system board processor has failed. | 1033 |
072523 | E | Internal disk file system is damaged. | 1187 |
072525 | E | Unable to update system board service processor firmware. | 1034 |
072535 | E | Canister internal PCIe switch failed. | 1192 |
072541 | E | Multiple hardware failures. | 1184 |
072550 | W | Cannot form cluster due to lack of cluster resources. | 1192 |
072551 | W | Cannot form cluster due to lack of cluster resources, overridequorum possible. | 1192 |
072556 | E | Duplicate WWNN detected on SAN. | 1133 |
072562 | E | The node's hardware configuration does not meet minimum requirements. | 1034 |
072564 | E | Too many software failures. | 1188 |
072565 | E | The node's internal drive is failing. | 1032 |
072569 | E | CPU over temp. | 1032 |
072573 | E | Node software inconsistent | 1187 |
072574 | E | Node software is damaged. | 1187 |
072576 | E | Cluster state and configuration data cannot be read. | 1032 |
072578 | E | State data was not saved on power loss. | 1194 |
072651 | W | The canister battery is missing. | 1153 |
072652 | E | The canister battery has failed. | 1154 |
072655 | E | Canister battery communications error. | 1158 |
072690 | W | Node held in service state | 1189 |
072700 | W | Fibre Channel adapter missing | 1045 |
072701 | E | Fibre Channel adapter failed | 1046 |
072702 | E | Fibre Channel adapter PCI error | 1046 |
072703 | E | Fibre Channel adapter degraded | 1046 |
072705 | W | Fewer Fibre Channel I/O ports operational. | 1450 |
072706 | W | Fibre Channel clustered system path failure. | 1550 |
072710 | W | SAS adapter missing. | 1045 |
072711 | E | SAS adapter failed. | 1046 |
072712 | E | SAS adapter PCI error. | 1046 |
072713 | E | SAS adapter degraded. | 1046 |
072715 | W | Fewer SAS ports operational. | 1046 |
072717 | W | SAS ports degraded. | 1046 |
072718 | W | SAS port connected to unsupported device. | 1669 |
072720 | W | Ethernet adapter missing. | 1045 |
072721 | E | Ethernet adapter failed . | 1046 |
072722 | E | Ethernet adapter PCI error. | 1046 |
072723 | E | Ethernet adapter degraded. | 1046 |
072724 | W | Fewer Ethernet ports | 1402 |
072730 | W | Bus adapter missing | 1032 |
072731 | E | Bus adapter failed | 1032 |
072732 | E | Bus adapter PCI error | 1032 |
072733 | E | Bus adapter degraded. | 1032 |
072734 | W | Fewer bus ports are operational. | 1006 |
072766 | E | CMOS error. | 1670 |
072840 | W | A hardware change was made that is not supported by software. User action is required to repair the hardware or update the software. | 1198 |
072841 | W | A supported hardware change was made to this node. User action is required to activate the new hardware. | 1199 |
072850 | W | Canister battery is nearing end of life. | 1159 |
072860 | W | Fibre-channel network fabric is too big. | 1800 |
073003 | W | The Fibre Channel ports are not operational. | 1060 |
073005 | E | System path has a failure. | 1550 |
073006 | W | The SAN is not correctly zoned. As a result, more than 512 ports on the SAN have logged into one system port. | 1800 |
073305 | W | Fibre Channel speed has changed. | 1065 |
073310 | E | Duplicate Fibre Channel frame is detected. | 1203 |
073402 | E | The Fibre Channel adapter has a failure. | 1032 |
073404 | E | Fibre Channel adapter has detected PCI bus error. | 1032 |
073500 | W | Incorrect enclosure. | 1021 |
073512 | E | Enclosure VPD is inconsistent. | 1008 |
073513 | E | Uncorrectable memory error was detected. | 1022 |
073522 | E | The system board service processor has failed. | 1034 |
073524 | E | Unable to update BIOS settings. | 1034 |
073528 | E | Ambient temperature is too high during system startup. | 1098 |
073541 | E | Multiple hardware failures. | 1184 |
073551 | W | Cannot form cluster due to lack of cluster resources, overridequorum possible. | 1192 |
073564 | W | Too many software failures. | 1188 |
073568 | E | Unable to upgrade adapter firmware. | 1469 |
073569 | E | CPU over temp. | 1032 |
073576 | E | Cluster state and configuration data cannot be read. | 1032 |
073690 | W | Node held in service state. | 1189 |
073715 | W | Fewer SAS ports are operational. | 1046 |
073717 | W | SAS ports degraded. | 1046 |
073718 | W | SAS port connected to unsupported device. | 1669 |
073765 | E | Service Processor shows fan failure. | 1192 |
073766 | E | CMOS error. | 1670 |
073776 | E | Power supply mains cable unplugged. | 1192 |
073820 | W | The node canister has detected that it has a hardware type that is not compatible with the control enclosure MTM. | 3020 |
073821 | E | Ambient thermal sensor fault | 1500 |
073830 | W | Encryption key required | 1328 |
073831 | W | Encryption key invalid | 2555 |
073832 | W | Encryption key not found | 2555 |
073833 | W | USB device (such as hub) unsupported | 2555 |
073836 | W | Encryption key required | 1328 |
073850 | W | Canister battery is nearing end of life | 1159 |
074001 | W | System is unable to determine VPD for a FRU. | 2040 |
074002 | E | The node warm started after a software error. | 2030 |
074003 | W | A connection to a configured remote system has been lost because of a connectivity problem. | 1715 |
074004 | W | A connection to a configured remote system has been lost because of too many minor errors. | 1716 |
074500 | W | Incorrect enclosure. | 1021 |
074501 | E | Incorrect slot. | 1192 |
074502 | E | No enclosure id and cannot get status from partner. | 1192 |
074503 | E | Incorrect enclosure type. | 1192 |
074504 | E | Enclosure id and partner does not match. | 1192 |
074505 | E | No enclosure id and partner has cluster data that does not match. | 1192 |
074506 | E | No enclosure id and no cluster state on partner | 1192 |
074507 | E | No enclosure id and no cluster state | 1192 |
074508 | W | Cluster id different between enclosure and node | 1023 |
074509 | E | Cannot read enclosure identity | 1043 |
074510 | E | The detected memory size does not match the expected memory size | 1039 |
074512 | E | Enclosure VPD is inconsistent | 1029 |
074521 | E | Unable to detect any fibre-channel adapter | 1192 |
074522 | E | The system board processor has failed | 1088 |
074523 | E | Internal disk file system is damaged | 1187 |
074524 | E | Unable to update BIOS settings | 1034 |
074525 | E | Unable to update system board service processor firmware | 1192 |
074528 | W | Ambient temperature too high while system starting | 1087 |
074534 | E | System board fault | 1039 |
074535 | E | Canister internal PCIe switch failed | 1034 |
074536 | E | A device on the system board is too hot | 1192 |
074538 | E | PCI Riser too hot | 1192 |
074541 | E | Multiple hardware failures | 1184 |
074550 | W | Cannot form cluster due to lack of cluster resources | 1192 |
074551 | W | Cannot form cluster due to lack of cluster resources, overridequorum possible | 1192 |
074556 | W | Duplicate WWNN detected on SAN | 1133 |
074562 | E | The node's hardware configuration does not meet minimum requirements | 1034 |
074564 | E | Too many software failures | 1188 |
074565 | E | The node's internal drive is failing. | 1039 |
074569 | E | CPU over temp. | 1192 |
074573 | E | Node software inconsistent | 1192 |
074574 | E | Node software is damaged | 1187 |
074576 | E | Cluster state and configuration data cannot be read | 1039 |
074578 | E | State data was not saved on power loss | 1194 |
074650 | W | The canister battery is not supported. | 1192 |
074651 | W | The canister battery is missing. | 1192 |
074652 | E | The canister battery failed. | 1192 |
074653 | W | The canister battery is below minimum operating temperature. | 1192 |
074654 | W | The canister battery is above maximum operating temperature. | 1192 |
074655 | E | Canister battery communications error. | 1192 |
074656 | W | Canister battery has insufficient charge to support a fire hose dump. | 1192 |
074657 | E | Not enough battery to support graceful shutdown. | 1111 |
074690 | W | Node held in service state | 1189 |
074710 | W | SAS adapter missing. | 1192 |
074711 | E | SAS adapter failed | 1192 |
074712 | E | SAS adapter PCI error | 1192 |
074713 | E | SAS adapter degraded | 1192 |
074715 | W | Fewer SAS ports operational | 1192 |
074717 | W | SAS ports degraded | 1192 |
074718 | W | SAS port connected to unsupported device | 1669 |
074720 | W | Ethernet adapter missing | 1039 |
074721 | E | Ethernet adapter failed | 1039 |
074722 | E | Ethernet adapter PCI error | 1034 |
074723 | E | Ethernet adapter degraded | 1034 |
074724 | W | Fewer Ethernet ports | 1401 |
074730 | W | Bus adapter missing | 1039 |
074731 | E | Bus adapter failed | 1039 |
074732 | E | Bus adapter PCI error | 1034 |
074733 | E | Bus adapter degraded | 1034 |
074734 | W | Fewer bus ports operational | 1007 |
074768 | W | Ambient temperature warning | 1099 |
074830 | W | Encryption key required | 1328 |
074831 | W | Encryption key invalid | 2555 |
074832 | W | Encryption key not found | 2555 |
074833 | W | USB device (such as hub) unsupported | 2555 |
074840 | W | A hardware change was made that is not supported by software. User action is required to repair the hardware or update the software. | 1198 |
074841 | W | A supported hardware change was made to this node. User action is required to activate the new hardware. | 1199 |
075510 | W | Memory errors were detected. | 510 |
075542 | W | CPU errors were detected. | 542 |
075721 | W | Network adapter errors were detected. | 721 |
075743 | W | A hardware error was detected on the boot disk. | 743 |
075775 | W | One or more power supply units stopped working. | 775 |
076001 | E | The internal disk for a node has failed. | 1030 |
076002 | E | The hard disk is full and cannot capture any more output. | 2030 |
076101 | E | Excessive correctable memory errors were detected. | 1022 |
076401 | E | One of the two power supply units in the node has failed. | 1096 |
076402 | E | One of the two power supply units in the node cannot be detected. | 1096 |
076403 | E | One of the two power supply units in the node is without power. | 1097 |
076502 | E | The PCIe lanes on a high-speed SAS adapter are degraded. | 1121 |
076503 | E | A PCI bus error occurred on a high-speed SAS adapter. | 1121 |
076504 | E | A high-speed SAS adapter requires a PCI bus reset. | 1122 |
076505 | E | The SAS adapter has an internal fault. | 1121 |
079500 | W | The limit on the number of system secure shell (SSH) sessions has been reached. | 2500 |
079501 | W | Unable to access the Network Time Protocol (NTP) network time server. | 2700 |
079503 | W | Unable to connect to NTP server that has been automatically configured. | 2702 |
079504 | W | Hardware configurations of nodes differ in an I/O group. | 1470 |
079505 | W | Stretch cluster reconfiguration is required to restore a dual site configuration | 1178 |
079508 | W | Performance not optimized for V9000 variants without managed enclosures. | 3300 |
079509 | W | Performance not optimized for V9000 variants with managed enclosures. | 3300 |
079510 | W | Node has USB ports enabled | 2065 |
082001 | E | A server error has occurred. | 2100 |
083001 | E | System failed to communicate with UPS. | 1145 |
083004 | E | UPS battery has a fault. | 1180 |
083006 | E | UPS frame has a fault. | 1175 |
083007 | E | UPS is overcurrent. | 1160 |
083009 | E | The UPS has detected an input power fault. | 1140 |
083010 | E | UPS has a cabling error. | 1150 |
083013 | E | UPS crossed-cable test is bypassed because of an internal UPS software error. | 3010 |
084000 | W | An array MDisk has deconfigured members and has lost redundancy. | 1689 |
084001 | W | Array mdisk cannot copyback due to degraded RAID status | 1679 |
084050 | W | An array MDisk is expected to fail within six months due to limited write endurance of member drives | 3060 |
084100 | E | An array MDisk is corrupt because of lost metadata. | 1240 |
084200 | W | Array MDisk has taken a spare member that does not match array goals. | 1692 |
084201 | W | An array has members that are located in a different I/O group. | 1688 |
084300 | W | An array MDisk is no longer protected by an appropriate number of suitable spares. | 1690 |
084301 | W | No spare protection exists for one or more array MDisks. | 1690 |
084302 | W | Distributed array MDisk has fewer rebuild areas available than threshold. | 1690 |
084400 | W | A background scrub process has found an inconsistency between data and parity on the array. | 1691 |
084420 | W | Array MDisk has been forced to disable hardware data integrity checking on member drives. | 2035 |
084500 | E | An array MDisk is offline. The metadata for the inflight writes is on a missing node. | 1243 |
084600 | E | An array MDisk is offline. Metadata on the missing node contains needed state information. | 1243 |
084700 | W | Array response time too high. | 1750 |
084701 | W | Distributed array MDisk member slow write count threshold exceeded. | 1750 |
084800 | E | Distributed array MDisk offline due to I/O timeout. | 1340 |
084801 | E | Array is using reserved physical capacity, recovery of redundancy could be compromised | 2090 |
085047 | W | Battery reconditioning required but not possible | 1131 |
085048 | W | Battery reconditioning required | 2060 |
085052 | E | Interface adapter has degraded PCI link | 1039 |
085063 | E | Canister is missing an interface adapter | 1045 |
085091 | W | External iSCSI port not operational | 1403 |
085092 | W | Too many ISCSI host logins | 1803 |
085118 | W | System update halted | 2010 |
085160 | W | Check the air filter | 1820 |
085161 | E | Array data compromised | 1048 |
085198 | W | Too many enclosures visible on fabric | 1807 |
085199 | W | Enclosure visible on fabric managed by another system | 1706 |
085200 | W | Cabling error. Internal cabling connectivity has changed. | 1440 |
085201 | W | Enclosure connectivity undetermined. Connectivity to an enclosure can no longer be determined | 1440 |
085202 | W | Minimal enclosure connectivity not met. | 1705 |
085203 | W | Config node cannot communicate with canister. | 1034 |
085204 | W | Managed enclosure is not visible from config node. | 1042 |
085205 | W | Canister internal error. | 1705 |
085222 | W | Write failed to USB Flash Drive | 1790 |
085336 | E | Flash module is manually marked for repair. | 1741 |
085369 | E | System Shutdown | N/A |
085370 | E | Internal encryption key is not valid or does not exist. | 1048 |
086001 | E | Encryption key unavailable | 1739 |
086002 | W | Encryption key on USB flash drive removed | 2550 |
086003 | W | Write to USB Flash Drive failure | 1790 |
086005 | W | Encryption not committed | 1780 |
086006 | W | Key Server reported KMIP error | 1785 |
086007 | W | Key Server reported vendor information error | 1785 |
086008 | W | Failed to connect to Key Server | 1785 |
086009 | W | Key Server reported misconfigured primary | 1785 |
087001 | E | Cloud gateway service restarted | 2031 |
087002 | E | Cloud gateway service restarted too often | 1404 |
087003 | W | Cloud account SSL certificate will expire within the next 30 days | 3140 |
087004 | W | Cloud account not available, cannot resolve hostname | 1580 |
087005 | W | Cloud account not available, cannot contact cloud provider | 2310 |
087006 | W | Cloud account not available, cannot communicate with cloud provider | 2320 |
087007 | W | Cloud account not available, no matching CA certificate | 2300 |
087008 | W | Cloud account not available, expired SSL certificate | 2300 |
087009 | W | Cloud account not available, cannot establish secure connection with cloud provider | 3100 |
087010 | W | Cloud account not available, cannot authenticate with cloud provider | 2330 |
087011 | W | Cloud account not available, cannot obtain permission to use cloud storage | 2330 |
087012 | W | Cloud account not available, cannot complete cloud storage operation | 3100 |
087013 | W | Cloud account not available, cannot access cloud object storage | 2105 |
087014 | W | Cloud account not available, incompatible object data format | 3135 |
087016 | W | Cloud account not available, cloud object storage encrypted | 1656 |
087017 | W | Cloud account not available, cloud object storage not encrypted | 1656 |
087018 | W | Cloud account not available, cloud object storage encrypted with the wrong key | 1657 |
087019 | W | No permission to use cloud storage snapshot operation | 2305 |
087020 | W | Cloud account out of space during cloud storage snapshot operation | 2125 |
087021 | W | Cannot create container object to cloud object storage during cloud snapshot operation | 2305 |
087022 | W | A cloud object could not be found during cloud snapshot operation. | 3108 |
087023 | W | A cloud object was found to be corrupt during cloud snapshot operation. | 3108 |
087024 | W | A cloud object was found to be corrupt during cloud snapshot decompression operation. | 3108 |
087025 | W | Etag integrity error during cloud snapshot operation | 3108 |
087026 | W | Internal Read error during cloud snapshot operation | 2120 |
087027 | W | Unexpected error occurred, cannot complete cloud snapshot operation | 3108 |
087028 | W | No permission to use cloud snapshot restore operation | 2305 |
087029 | W | A cloud object was not found during a cloud snapshot restore operation. | 3108 |
087030 | W | A cloud object was found to be corrupt during a cloud snapshot restore operation | 3108 |
087031 | W | A cloud object was found to be corrupt during a cloud snapshot restore decompression operation | 3108 |
087032 | W | Etag integrity error during cloud snapshot restore operation | 3108 |
087033 | W | Internal write error during cloud snapshot operation | 2120 |
087034 | W | Cannot create bad blocks on a managed disk during cloud snapshot restore operation. | 3108 |
087035 | W | Unexpected error occurred, cannot complete cloud snapshot restore operation | 3108 |
087036 | W | No permission to use cloud snapshot delete operation | 2305 |
087037 | W | A cloud object was not found during a cloud snapshot delete operation. | 3108 |
087038 | W | A cloud object was found to be corrupt during cloud snapshot delete operation | 3108 |
087039 | W | A cloud object was found to be corrupt during cloud snapshot delete decompression operation | 3108 |
087040 | W | Unexpected error occurred, cannot complete cloud snapshot delete operation | 3108 |
087044 | W | Cloud account out of space during cloud snapshot restore commit operation | 2125 |
087045 | W | Cloud account out of space during cloud snapshot delete operation | 2125 |
087046 | W | Transparent Cloud Tiering feature license limit exceeded. | 3032 |
087048 | W | Too many node restarts have occurred, cloud backup operations paused | 3104 |
087049 | W | Internal FlashCopy error on volume enabled for cloud snapshots. | 2118 |
088000 | E | SCSI or NVMeFC NPIV host port failed to login to fabric | 1300 |
088001 | E | A fibrechannel target port mode transition was not successful | 1300 |
088002 | W | Equivalent fibre channel ports are reporting that they are connected to different fabrics | 3220 |
088003 | W | A spare node in this cluster is not providing additional redundancy | 1380 |
088004 | W | A spare node could not be automatically removed from the cluster | 3180 |
089001 | W | Single PSU failure in bare metal server | 1810 |
089002 | W | Node IP missing, only single path connection available between nodes | 1811 |
089003 | W | The IP connections between nodes were broken | 1812 |
089004 | W | A node rejoined cluster with identity changed | 1813 |
089005 | E | The node is not authorized to perform an operation. | 1817 |
089006 | E | The node operation failed because of network security rules. | 1818 |
090000 | E | NVMe drive port offline due to errors | 1685 |
090001 | E | NVMe drive offline due to excessive processing time | 1685 |
090002 | E | NVMe drive offline | 1685 |
090003 | E | NVMe drive over temperature | 1095 |
090004 | E | NVMe drive is reporting expected failure | 1680 |
090005 | E | NVMe drive is reporting excessive media errors | 1680 |
090006 | E | NVMe drive is experiencing excessive timeouts | 1680 |
090007 | E | NVMe drive slow detected | 1680 |
090008 | E | NVMe drive detecting too many T10dif errors | 1680 |
090009 | E | NVMe drive slow detected | 1680 |
090010 | E | NVMe drive is reporting end of life due to flash degradation | 1680 |
090011 | W | NVMe unsupported drive inserted | 1666 |
090012 | W | NVMe drive requires formatting | 1206 |
090013 | W | NVMe drive requires formatting due to incorrect data protection type | 1206 |
090015 | W | NVMe drive temperature warning | 1098 |
090016 | W | NVMe drive media error | 1321 |
090017 | W | NVMe drive error recovery procedure occurred | 1685 |
090018 | W | NVMe drive reported t10 data protection error | 1322 |
090019 | W | NVMe drive experienced timeout | 1340 |
090020 | W | Too many NVMe drives attached to the system | 1179 |
090021 | W | NVMe drive firmware download failed | 3090 |
090022 | W | NVMe quorum disk is unavailable | 1335 |
090023 | E | NVMe drive is behaving out-of-specification and is likely faulty | 1215 |
090024 | W | NVMe drive experienced timeout | 1340 |
090025 | W | NVMe Flash Core Module is experiencing excessive hardware errors. | 1680 |
090026 | E | NVMe drive port is offline. | |
090027 | E | Drive offline because it is locked by a missing encryption key. | 1674 |
090028 | E | NVMe drive is reporting a degraded PCIe link speed | 1686 |
090029 | E | NVMe drive is reporting a degraded PCIe link width | 1686 |
090030 | E | NVMe drive is reporting excessive PCIe link errors | 1215 |
090031 | W | SCM NVMe drive is in an incorrect slot. | 3415 |
090032 | W | NVMe drive secure erase failed | 3340 |
090033 | E | NVMe drive encryption error | 1674 |
090034 | E | NVMe drive encryption timeout | 1674 |
090035 | W | Drive firmware download process skipped drives by recommendation of the update test utility. | 3360 |
091000 | W | LD: Managed disk is detached from web console. | 1814 |
091001 | W | LD: Managed disk is deleted from web console. | 1815 |
091002 | W | LD: Managed disk tag is changed by user. | 1340 |
091003 | W | LD: Local mdisk offline due to IO timeout. | 1816 |
987303 | E | Compression suspended too many times. | 3400 |
989001 | W | Managed Disk Group space warning. | 1866 |
989007 | W | Unable to send to the cloud callhome servers | 3201 |
Error codes are listed in numerical order.