Management interface events
Use this section to locate additional information about TS7700 Management Interface event messages. Codes associated with these messages begin with the identifiers HYDIN and OP.
Note: Event codes are shown as HYDINxxxy in the Management Interface and as OPxxxx in the host
console log. For example, HYDIN0003I/OP0003.
Expand the Management interface events parent topic in the left navigation pane to view the complete list of HYDIN/OP event codes.
- HYDIN0000I (OP0000)
- HYDIN0003I (OP0003)
The I/O station is full. - HYDIN0004I (OP0004)
The virtual library is full. - HYDIN0017W (OP0017)
A load or unload failure has occurred on device: device serial number. - HYDIN0045I (OP0045)
VOLSER cartridge label cannot be removed from its home location. - HYDIN0048W (OP0048)
A VOLSER VOLSER has an incorrect media type on the external label. - HYDIN0066I (OP0066)
One or more volumes have been inserted into the library and marked unassigned. - HYDIN0100I (OP0100)
A read-only physical volume stacked volume cartridge label has been ejected. - HYDIN0101E (OP0101)
The cluster is out of empty physical volumes. - HYDIN0102W (OP0102)
A physical volume has a label error. Internal: stacked volume label, External: stacked volume label - HYDIN0103E (OP0103)
A permanent, non-recoverable tape volume cache error has occurred. - HYDIN0106I (OP0106)
Virtual volume virtual volume VOLSER was only partially read. - HYDIN0107W (OP0107)
Virtual volume virtual volume VOLSER was not fully recovered from damaged physical volume stacked volume VOLSER. - HYDIN0112W (OP0112)
Device serial number device serial number has been made offline and/or unavailable by the TS7700 Engine with a reason code of reason code. - HYDIN0115I (OP0115)
The cluster attempted unsuccessfully to eject a damaged physical volume stacked volume VOLSER. - HYDIN0120I (OP0120)
Mount of virtual volume virtual volume VOLSER failed because physical volume stacked volume VOLSER is misplaced. (reason code=error code) - HYDIN0121W (OP0121)
Mount of virtual volume virtual volume VOLSER failed because physical volume stacked volume VOLSER is inaccessible. - HYDIN0122W (OP0122)
Mount of virtual volume virtual volume VOLSER located on physical volume stacked volume VOLSER failed. (reason code=error code) - HYDIN0123I (OP0123)
Physical volume stacked volume VOLSER is in read-only status due to successive media errors. - HYDIN0124W (OP0124)
Physical volume cartridge label is unavailable. - HYDIN0127E (OP0127)
An invalid mixture of physical drive types was detected. - HYDIN0128E (OP0128)
The TS7700 Engine does not have enough physical drives to continue operation. - HYDIN0130I (OP0130)
Physical volume physical stacked volume VOLSER failed scratch mount. Its label cannot be read and the tape must be re-initialized. - HYDIN0134I (OP0134)
Physical volume stacked volume VOLSER is write-protected. - HYDIN0135I (OP0135)
The TS7700 unsuccessfully attempted to eject write-protected physical volume stacked volume VOLSER. - HYDIN0136I (OP0136)
Physical volume stacked volume VOLSER was moved to category FF08 due to unrecovered active data. - HYDIN0138E (OP0138)
The common scratch pool (Pool 00) is out of media type media physical volumes. - HYDIN0139E (OP0139)
Storage Pool storage pool number is out of scratch physical volumes. - HYDIN0140I (OP0140)
VOLSER VOLSER could not be moved from Storage Pool source pool number to Storage Pool target pool number. Error code = error code. - HYDIN0144W (OP0144)
Eject failed on physical volume VOLSER that contains active data. Error code = error code. - HYDIN0149E (OP0149)
Storage Pool storage pool number is out of write compatible physical scratch volumes. - HYDIN0150I (OP0150)
The physical volume VOLSER has become degraded. This condition is the result of a media condition report. - HYDIN0152I (OP0152)
Active data on ejected physical volume VOLSER needs to be recovered. - HYDIN0153I (OP0153)
Physical volume stacked volume VOLSER is misplaced. - HYDIN0164I (OP0164)
The TS7700 Engine has initiated auto removal of volumes on this disk-only cluster. - HYDIN0165I (OP0165)
One or more non-writable physical volumes were found. - HYDIN0166I (OP0166)
Copy Export did not export physical volume VOLSER because of an incorrect format. - HYDIN0167I (OP0167)
Unsupported media (for example: JA, JJ) is set for First Media, Second Media, or both for Physical Volume Pool(s): pool numbers. - HYDIN0168I (OP0168)
One or more unsupported empty media has been found and cannot be used by the installed tape drives. - HYDIN0169E (OP0169)
The cache type is out of cache space. The total used, space usage TiB, is less than 1 TiB from the total cache space or less than 5% below the total cache space, total space TiB. - HYDIN0170W (OP0170)
The cache type has limited cache free space. The total used, space usage TiB, is less than 3 TiB from the total cache space or less than 15% of total cache space, total space TiB. - HYDIN0171W (OP0171)
Unsupported scratch media of type media type were inserted into the library. - HYDIN0172I (OP0172)
Automatic removal of logical volumes on this cluster has been disabled due to a small cache resident-only partition size. - HYDIN0173I (OP0173)
Automatic removal of logical volumes on this cluster has been enabled because the cache resident-only partition size is now sufficient. - HYDIN0200W (OP0200)
The local cluster is operating in immediate copy mode and at least one copy did not finish prior to the completion of the Rewind/Unload command. - HYDIN0201I (OP0201)
All immediate deferred copy operations are complete. - HYDIN0202W (OP0202)
One or more volumes opened as part of a synchronous mode copy operation did not synchronize completely across both clusters. - HYDIN0203I (OP0203)
Synchronization across both clusters has completed for all volumes that were in the synchronous deferred state. - HYDIN0204W (OP0204)
Copy operations for the local cluster are disabled by the system. - HYDIN0205I (OP0205)
The system has enabled copy operations at the local cluster. - HYDIN0206I (OP0206)
Copy operations for the local cluster are disabled by the host. - HYDIN0207I (OP0207)
Copy operations for the local cluster are enabled by the host. - HYDIN0310I (OP0310)
The data class data class was automatically created with the default actions for volume virtual volume VOLSER. - HYDIN0311I (OP0311)
The Storage Class storage class was automatically created with the default actions for volume virtual volume VOLSER. - HYDIN0312I (OP0312)
The Management Class management class was automatically created with the default actions for volume virtual volume VOLSER. - HYDIN0313I (OP0313)
The Storage Group storage group was automatically created with the default actions for volume virtual volume VOLSER. - HYDIN0314I (OP0314)
The inhibit create command was ignored and one or more constructs were automatically created with the default actions for volume virtual volume VOLSER as a result of an imbalance of defined SMS constructs across the Domain. - HYDIN0315I (OP0315)
The maximum number of defined constructs has been reached. An imbalance of defined SMS constructs across the domain has occurred. Default constructs were assigned for volume virtual volume VOLSER. - HYDIN0316E (OP0316)
The TS7700 Engine has detected corrupted tokens for one or more virtual volumes. - HYDIN0409I (OP0409)
The volume hold function was disabled for scratch category scratch category. - HYDIN0410I (OP0410)
The hold/expire time has been changed to hours hours for scrath category scratch category. - HYDIN0411I (OP0411)
A fast-ready attribute was deleted for category scratch category. - HYDIN0428W (OP0428)
The 3584 library reported a hardware error (error data). Contact your IBM service representative. - HYDIN0433I (OP0433)
The Send Interventions to Host Console setting on the Events panel has been turned on. - HYDIN0434I (OP0434)
The Send Interventions to Host Console setting on the Events panel has been turned off. - HYDIN0439W (OP0439)
The TS7700 lost communication with the primary Encryption Key Server. - HYDIN0440W (OP0440)
The TS7700 lost communications with the alternate Encryption Key Server. - HYDIN0442I (OP0442)
Physical volume stacked volume VOLSER is inaccessible. - HYDIN0443I (OP0443)
The virtual tape library has detected an inconsistency with the physical tape library. - HYDIN0444W (OP0444)
LM PC has not been rebooted in 6 months. - HYDIN0445W (OP0445)
The primary Encryption Key Server was set to UNAVAILABLE. - HYDIN0446W (OP0446)
The alternate Encryption Key Server was set to UNAVAILABLE. - HYDIN0448I (OP0448)
More than error quantity errors were encountered for physical volume stacked volume VOLSER. - HYDIN0449I (OP0449)
Pool storage pool number has physical volumes of the wrong media class. - HYDIN0450I (OP0450)
The media type of VOLSER VOLSER does not match its VOLSER range. The VOLSER was not assigned to a cluster. - HYDIN0451E (OP0451)
Encryption is enabled. No Encryption Key Servers are configured. - HYDIN0452W (OP0452)
Encryption Key Server error Encryption Key Server error number prevented device drive serial number from encrypting data in storage pool storage pool number. - HYDIN0453W (OP0453)
Device drive serial number could not append encrypted data to cartridge cartridge volser (Encryption Key Server error Encryption Key Server error number). - HYDIN0454W (OP0454)
Device drive serial number could not decrypt data from cartridge cartridge volser (Encryption Key Server error Encryption Key Server error number). - HYDIN0455W (OP0455)
Device device serial number is not in 3592 E05 Native mode. The Device was made unavailable. - HYDIN0456W (OP0456)
Encryption is enabled on the virtual tape library. Device device serial number is not enabled for system-managed encryption. - HYDIN0468W (OP0468)
The 3494 Library Manager has an event. - HYDIN0469W (OP0469)
The 3494 Library Manager is in a degraded state. - HYDIN0470I (OP0470)
Delete Expire capability has been disabled. - HYDIN0471E (OP0471)
The Field Microcode Replacement tape stacked volume VOLSER cannot be used as a data cartridge. - HYDIN0472I (OP0472)
The database backup to physical volume VOLSER failed during the Copy Export operation as a result of a media error. - HYDIN0473I (OP0473)
A media error occurred during the Copy Export operation and the physical volume VOLSER has been ejected. The medium may be degraded, and should not be reused in an export pool. - HYDIN0474I (OP0474)
The Copy Export operation did not export physical volume VOLSER because the primary copy for virtual volume VOLSER is currently unavailable. - HYDIN0475I (OP0475)
Copy Export did not export virtual volume VOLSER because it was not able to premigrate the volume to the export pool. - HYDIN0476I (OP0476)
The event was cleared automatically. - HYDIN0477I (OP0477)
The event was cleared by user. - HYDIN0480I (OP0480)
Service Call Home will be initiated. - HYDIN0481I (OP0481)
Service Call Home was initiated. - HYDIN0482I (OP0482)
Service Call Home was initiated with PMR number PMR number. - HYDIN0483E (OP0483)
A permanent cache problem was encountered. - HYDIN0484E (OP0484)
A permanent cache problem was encountered. - HYDIN0485E (OP0485)
A 3956-CC6 permanent check was encountered. - HYDIN0486E (OP0486)
A CHECK1 condition was encountered. - HYDIN0487E (OP0487)
An adapter microcode CHECK1 condition occurred. - HYDIN0488E (OP0488)
A channel event occurred. - HYDIN0489E (OP0489)
An undetermined error occurred. - HYDIN0490E (OP0490)
An operator notification occurred. - HYDIN0491E (OP0491)
A microcode exception occurred in the ATL daemon. - HYDIN0492E (OP0492)
An undetermined error occurred. - HYDIN0493E (OP0493)
An informational message was presented by CU. - HYDIN0494E (OP0494)
An environmental problem has occurred. - HYDIN0495E (OP0495)
A microcode exception occurred in the tape daemon. - HYDIN0496E (OP0496)
The tape daemon detected a CRC error. - HYDIN0497E (OP0497)
A microcode exception occurred in the tape daemon. - HYDIN0498E (OP0498)
A microcode exception occurred in the BATE daemon. - HYDIN0499I (OP0499)
An error was detected and a Service Call Home has been generated. The call home includes the following SIM(s): SIMID-RESOURCE-REF_CODES SIM - HYDIN0500I (OP0500)
The times displayed by the local and remote clusters remote cluster differ by more than 5 seconds. - HYDIN0510I (OP0510)
user name logged into the Web interface. - HYDIN0511I (OP0511)
user name logged out of the Web interface. - HYDIN0512I (OP0512)
User action the setting to send future events to host. - HYDIN0514I (OP0514)
Custom Role role has been changed. - HYDIN0515I (OP0515)
SNMP settings have changed.\n Values are:\n SNMP Version: version\n Enable SNMP Traps: enabled\n Trap Community Name: community\n - HYDIN0516I (OP0516)
Stand-alone mount was initiated for volume var0 on device var1. - HYDIN0517I (OP0517)
Stand-alone demount was initiated on device var0. - HYDIN0518I (OP0518)
Node var0 has been shut down. - HYDIN0519I (OP0519)
Custom Role role has been created. - HYDIN0520I (OP0520)
Custom Role role has been deleted. - HYDIN0521I (OP0521)
The security settings for local authentication have changed. \n \nLocal Account Expiration: Enabled. \nThe account will expire if the password is not changed in time days. - HYDIN0522I (OP0522)
The security settings for local authentication have changed. \n \nLocal Account Expiration: Disabled. - HYDIN0523I (OP0523)
The security settings for local authentication have changed. \n \nLocal Account Lock: Enabled. \nThe account will be locked after attempts unsuccessful attempts to enter the password. - HYDIN0524I (OP0524)
The security settings for local authentication have changed. \n \nLocal Account Lock: Disabled. - HYDIN0525E (OP0525)
A TAPE DRIVE FAILURE has occurred - HYDIN0526E (OP0526)
A FibrePath, FibreSwitch, or FibreInterface error has occurred. - HYDIN0527I (OP0527)
Stand-alone mount for volume var0 on device var1 completed successfully. - HYDIN0528I (OP0528)
Stand-alone demount for volume var0 on device var1 completed successfully. - HYDIN0529W (OP0529)
Stand-alone mount for volume var0 on device var1 failed with error code var2. - HYDIN0530W (OP0530)
Stand-alone demount for volume var0 on device var1 failed with error code var2. - HYDIN0531W (OP0531)
The network connection on grid port port number with IP address: IP address experienced a possible loss of connectivity. - HYDIN0532E (OP0532)
The network connection on grid port port number with IP address: IP address is not responding. - HYDIN0533I (OP0533)
The connection between the local cluster and the remote cluster cluster with remote port remote port and IP address: remote cluster IP address was interrupted. - HYDIN0534W (OP0534)
The connection between the local cluster and the remote cluster cluster with remote portremote port and IP address: remote cluster IP address of the remote cluster is losing packets, or the connection was unavailable. - HYDIN0535E (OP0535)
The connection of local cluster to remote cluster cluster with remote portremote port and IP address: remote cluster IP address of the remote cluster, was not available. - HYDIN0536E (OP0536)
The link to remote cluster: remote cluster with IP address: remote cluster IP address is in the offline state. - HYDIN0537I (OP0537)
The connection of local cluster to remote cluster cluster with remote portremote port and remote IP address: remote cluster IP address was unavailable for a brief time or because the local cluster was unable to retrieve the status of the remote adapter. - HYDIN0538W (OP0538)
The connection of local cluster to remote cluster cluster with remote port remote port and remote IP address: remote cluster IP address was not available, because the local cluster reports the status of the remote adapter as not available. - HYDIN0539E (OP0539)
The connection of local cluster to remote cluster cluster with remote port remote port and IP address: remote cluster IP address of the remote cluster was not available, because the state of the remote adapter appears as Failed. - HYDIN0540E (OP0540)
The link to remote cluster: remote cluster With IP address: remote cluster IP address is in the offline state. NTC (Network Traffic Controller) reports link state: link state - HYDIN0541W (OP0541)
The link to gateway IP gateway IP address is degraded. - HYDIN0542E (OP0542)
The link to gateway IP gateway IP address has failed. - HYDIN0543W (OP0543)
The primary and alternate grid adapters have different speeds:\n Primary var0 link speed is: primary link speed\n Alternate var2 link speed is: alternate link speed - HYDIN0544E (OP0544)
The primary grid Ethernet adapter var0 is down. - HYDIN0545E (OP0545)
The alternate grid Ethernet adapter var0 is down. - HYDIN0546I (OP0546)
Could not retrieve the date on cluster cluster. - HYDIN0547E (OP0547)
A time synchronization failure was detected between cluster var0 and Cluster var1. - HYDIN0548W (OP0548)
There is no communication with one or more clusters in the Grid. - HYDIN0549W (OP0549)
One or more clusters in the Grid are in Service status. - HYDIN0550I (OP0550)
Service Call Home, TSSC was unable to generate a PMR number - HYDIN0551E (OP0551)
A permanent cache problem was encountered. - HYDIN0552E (OP0552)
A temporary cache problem was encountered. - HYDIN0553E (OP0553)
The cache has an unreadable sector. - HYDIN0554E (OP0554)
A cache power supply has failed. - HYDIN0555E (OP0555)
A cache power or fan assembly has failed. - HYDIN0556E (OP0556)
The cache has lost redundancy. - HYDIN0557E (OP0557)
A problem exists with the cabling or drive path inside the cache enclosure. - HYDIN0558E (OP0558)
A cache component has failed or been removed. - HYDIN0559E (OP0559)
A cache controller has failed or been removed. - HYDIN0560E (OP0560)
An environmental service module (ESM) canister in the cache has failed or been removed. - HYDIN0561E (OP0561)
A cache drive is missing. - HYDIN0562E (OP0562)
A cache drive is in a degraded state. - HYDIN0563E (OP0563)
A cache disk has reported errors. - HYDIN0564E (OP0564)
A cache RAID array has failed drives. - HYDIN0565E (OP0565)
An unsupported number of drive enclosures exists on a cache loop. - HYDIN0566E (OP0566)
The reported data rate of a cache drive channel is outside the expected range. - HYDIN0567E (OP0567)
The data rate could not be obtained on a drive channel for the cache. - HYDIN0568E (OP0568)
An incorrect number of enclosures exists on a cache loop. - HYDIN0569E (OP0569)
The number of enclosures on a cache loop cannot be determined. - HYDIN0570E (OP0570)
Mismatched drives exist in a cache array. - HYDIN0571E (OP0571)
Disk operation in the cache is degraded. - HYDIN0572I (OP0572)
Network errors were detected while connecting to the cache. - HYDIN0573E (OP0573)
An unreadable sector exists in the cache. - HYDIN0574E (OP0574)
A parity error occurred in the cache. - HYDIN0575E (OP0575)
A cache media error occurred. - HYDIN0576I (OP0576)
A temporary cache problem was encountered. - HYDIN0577E (OP0577)
The cache has an unreadable sector. - HYDIN0578E (OP0578)
A cache power supply has failed. - HYDIN0579E (OP0579)
A cache power or fan assembly has failed. - HYDIN0580E (OP0580)
The cache has lost redundancy. - HYDIN0581E (OP0581)
A problem exists with the cabling or drive path inside the cache enclosure. - HYDIN0582E (OP0582)
A cache component has failed or been removed. - HYDIN0583E (OP0583)
A cache controller has failed or been removed. - HYDIN0584E (OP0584)
An environmental service module (ESM) canister in the cache has failed or been removed. - HYDIN0585E (OP0585)
A cache drive is missing. - HYDIN0586E (OP0586)
A cache drive is in a degraded state. - HYDIN0587E (OP0587)
A cache disk has reported errors. - HYDIN0588E (OP0588)
A cache RAID array has failed drives. - HYDIN0589E (OP0589)
An unsupported number of drive enclosures exists on a cache loop. - HYDIN0590E (OP0590)
The reported data rate of a cache drive channel is outside the expected range. - HYDIN0591E (OP0591)
The data rate could not be obtained on a drive channel for the cache. - HYDIN0592E (OP0592)
An incorrect number of enclosures exists on a cache loop. - HYDIN0593E (OP0593)
The number of enclosures on a cache loop cannot be determined. - HYDIN0594E (OP0594)
Mismatched drives exist in a cache array. - HYDIN0595E (OP0595)
Disk operation in the cache is degraded. - HYDIN0596E (OP0596)
Network errors were detected while connecting to the cache. - HYDIN0597E (OP0597)
An unreadable sector exists in the cache. - HYDIN0598E (OP0598)
A parity error occurred in the cache. - HYDIN0599E (OP0599)
A cache media error occurred. - HYDIN0600E (OP0600)
A temporary cache problem was encountered. - HYDIN0601E (OP0601)
The cache has an unreadable sector. - HYDIN0602E (OP0602)
A cache power supply has failed. - HYDIN0603E (OP0603)
A cache power or fan assembly has failed. - HYDIN0604E (OP0604)
The cache has lost redundancy. - HYDIN0605E (OP0605)
A problem exists with the cabling or drive path inside the cache enclosure. - HYDIN0606E (OP0606)
A cache component has failed or been removed. - HYDIN0607E (OP0607)
A cache controller has failed or been removed. - HYDIN0608E (OP0608)
An environmental service module (ESM) canister in the cache has failed or been removed. - HYDIN0609E (OP0609)
A cache drive is missing. - HYDIN0610E (OP0610)
A cache drive is in a degraded state. - HYDIN0611E (OP0611)
A cache disk has reported errors. - HYDIN0612E (OP0612)
A cache RAID array has failed drives. - HYDIN0613E (OP0613)
An unsupported number of drive enclosures exists on a cache loop. - HYDIN0614E (OP0614)
The reported data rate of a cache drive channel is outside the expected range. - HYDIN0615E (OP0615)
The data rate could not be obtained on a drive channel for the cache. - HYDIN0616E (OP0616)
An incorrect number of enclosures exists on a cache loop. - HYDIN0617E (OP0617)
The number of enclosures on a cache loop cannot be determined. - HYDIN0618E (OP0618)
Mismatched drives exist in a cache array. - HYDIN0619E (OP0619)
Disk operation in the cache is degraded. - HYDIN0620E (OP0620)
Network errors were detected while connecting to the cache. - HYDIN0621E (OP0621)
An unreadable sector exists in the cache. - HYDIN0622E (OP0622)
A parity error occurred in the cache. - HYDIN0623E (OP0623)
A cache media error occurred. - HYDIN0624E (OP0624)
An error was detected in the disk cache. - HYDIN0625E (OP0625)
A system reboot interrupted a call home. - HYDIN0626I (OP0626)
One or more issues on the system have persisted for longer than 48 hours. - HYDIN0627E (OP0627)
There is a problem with network communication required for autonomic ownership takeover. - HYDIN0628E (OP0628)
The cache controller is not configured. - HYDIN0629E (OP0629)
The cache file system is inefficiently allocating its available space. - HYDIN0630E (OP0630)
There is a problem with the network fail over code. - HYDIN0631E (OP0631)
The error detection feature has restarted five times in 24 hours. - HYDIN0632E (OP0632)
The available memory is not configured correctly. - HYDIN0633E (OP0633)
A CPU has failed. - HYDIN0634E (OP0634)
Port 0 on the customer network has failed. - HYDIN0635E (OP0635)
Port 1 on the customer network has failed. - HYDIN0636E (OP0636)
Both Ethernet routers have failed. - HYDIN0637E (OP0637)
The primary Ethernet router has failed. - HYDIN0638E (OP0638)
The alternate Ethernet router has failed. - HYDIN0639E (OP0639)
The Network Time Protocol (NTP) server is not responding. - HYDIN0640E (OP0640)
A port in an Ethernet router has failed. - HYDIN0641E (OP0641)
A port in an Ethernet router shows increasing errors. - HYDIN0642E (OP0642)
Communication between the disk cache and the primary switch has failed. - HYDIN0643E (OP0643)
Communication between the disk cache and the alternate switch has failed. - HYDIN0644E (OP0644)
One or more arrays are not encrypted. - HYDIN0645I (OP0645)
This is a cache Call Home test. - HYDIN0646W (OP0646)
Encryption is enabled on the virtual tape library. Device device serial number is not encryption-capable. The device was made unavailable. - HYDIN0647E (OP0647)
Host adapter adapter is offline. - HYDIN0648I (OP0648)
The link link number to host adapter ficon adapter is unavailable. - HYDIN0649E (OP0649)
No IBM media changer devices were found on the system. - HYDIN0650W (OP0650)
The system identified number of smc devices IBM media changer devices. This is an incorrect number of devices. - HYDIN0651I (OP0651)
The IBM media changer smc device name is in an unknown state. - HYDIN0652I (OP0652)
The fibre channel adapter for tape interface interface number cannot be identified. - HYDIN0653I (OP0653)
The drive name drive name does not match port port name. - HYDIN0654E (OP0654)
Drives could not be configured on a 3590 or 3592 tape drive. - HYDIN0655W (OP0655)
The physical tape SCSI device rmt device is in the state: device state. - HYDIN0656E (OP0656)
Primary and alternate paths for tape SCSI device rmt device are unavailable. - HYDIN0657W (OP0657)
The tape drive device rmt device is shown as device state in the cluster. - HYDIN0658I (OP0658)
The tape drive device rmt device is in the state device state. - HYDIN0659W (OP0659)
The path primary or alternate for tape drive rmt device name is unavailable. - HYDIN0660E (OP0660)
Both primary and alternate paths for tape drive device rmt device name are unavailable. - HYDIN0661I (OP0661)
Tape device rmt device name is in an unknown state. - HYDIN0662I (OP0662)
The path Primary or Alternate to tape device rmt device name is disabled. - HYDIN0663E (OP0663)
No tape drives were found in the system. - HYDIN0664W (OP0664)
All paths on the primary or alternate lower channel protocol interface failed. - HYDIN0665E (OP0665)
All paths on the primary and alternate lower fibre channel protocol interface failed. - HYDIN0666E (OP0666)
The primary and alternate paths for rmt device name on the lower fibre channel protocol interface failed. - HYDIN0667W (OP0667)
The tape SCSI device path rmt device name on lower fibre channel protocol interface failed. - HYDIN0668I (OP0668)
The state of the drive device name on the Library type model could not be obtained. - HYDIN0669I (OP0669)
The tape drive device name is not available to the phyiscal library Library type model. - HYDIN0670I (OP0670)
This system contains both E05 drives in native mode and J1A drives. - HYDIN0671I (OP0671)
All drives are reported as in the busy state. - HYDIN0672I (OP0672)
The world wide node name (WWNN) could not be obtained for drive device name. - HYDIN0673I (OP0673)
The physical volume status could not be obtained. - HYDIN0674I (OP0674)
No physical volumes are found on the system. - HYDIN0675I (OP0675)
The physical volume pool status could not be obtained. - HYDIN0676W (OP0676)
Physical volume pool pool name is out of scratch volumes. - HYDIN0677I (OP0677)
Volume volume name reports a state volume state with access in access status status. - HYDIN0678I (OP0678)
One or more IP addresses (IP addresses) of the Connection LDAP server are losing packets or one or more ports are unavailable. - HYDIN0679E (OP0679)
One or more IP addresses (IP addresses) of the Connection LDAP server are unreachable or one or more ports or adapters might have failed. - HYDIN0680E (OP0680)
LDAP server service is down. IP:IP Port:Port Number - HYDIN0681W (OP0681)
LDAP server connection is not correctly configured. IP: IP Port:port number - HYDIN0682I (OP0682)
Authentication server AuthServer id connection (IP) experienced a loss of connectivity. - HYDIN0683E (OP0683)
Authentication server AuthServer id service is down. IP:IP Port:Port number - HYDIN0684W (OP0684)
The connection to authentication server AuthServer id is not correctly configured. IP: IP Port:Port number - HYDIN0687E (OP0687)
An unknown cache problem was encountered. Disk model: Disk Model. - HYDIN0688E (OP0688)
The cache has an unreadable sector error. Disk model: Disk Model. - HYDIN0689E (OP0689)
A cache power supply has failed. Disk model: Disk Model. - HYDIN0690E (OP0690)
A loss of redundancy has occurred in cache. Disk model: Disk Model - HYDIN0691E (OP0691)
A problem exists with the cabling or drive path inside the cache enclosure. Disk model: Disk Model. - HYDIN0692E (OP0692)
A DDM is missing. Disk model: Disk Model - HYDIN0693E (OP0693)
A cache controller has failed or been removed. Disk model: Disk Model - HYDIN0694E (OP0694)
An environmental service module (ESM) canister in the cache has failed or been removed. Disk model: Disk Model - HYDIN0695E (OP0695)
A cache component has failed or been removed. Disk model: Disk Model - HYDIN0696E (OP0696)
Failed drives exist in a cache RAID array. Disk model: Disk Model - HYDIN0697E (OP0697)
Mismatched drives exist in a cache array. Disk model: Disk Model - HYDIN0698E (OP0698)
Disk operation in the cache is degraded. Disk model: Disk Model - HYDIN0699W (OP0699)
Network errors were detected while connecting to the cache. Disk model: Disk Model - HYDIN0700E (OP0700)
An unsupported number of drive enclosures exists on a cache loop. Disk model: Disk Model - HYDIN0701E (OP0701)
The reported data rate of a cache drive channel is outside the expected range. Disk model: Disk Model - HYDIN0702E (OP0702)
The data rate could not be obtained on a drive channel for the cache. Disk model: Disk Model - HYDIN0703E (OP0703)
An incorrect number of enclosures exists on a cache loop. Disk model: Disk Model - HYDIN0704E (OP0704)
The number of enclosures on a cache loop cannot be determined. Disk model: Disk Model - HYDIN0705E (OP0705)
An unreadable sector exists in the cache. Disk model: Disk Model - HYDIN0706E (OP0706)
A disk cache parity mismatch error occurred in the cache. Disk model: Disk Model - HYDIN0707E (OP0707)
A cache media error occurred. Disk model: Disk Model - HYDIN0708E (OP0708)
A cache power or fan assembly has failed. Disk model: Disk Model - HYDIN0709E (OP0709)
A cache drive is in a degraded state. Disk model: Disk Model - HYDIN0710E (OP0710)
A cache disk has reported errors. Disk model: Disk Model - HYDIN0711E (OP0711)
The cache battery is in a degraded state. Disk model: Disk Model - HYDIN0712E (OP0712)
The cache controller is in a degraded state. Disk model: Disk Model - HYDIN0713E (OP0713)
Information for this event cannot be displayed on this cluster. - HYDIN0714W (OP0714)
A cache DDM has failed. String: string, enclosure: enclosure, slot: slot. The disk model is: disk model. - HYDIN0715I (OP0715)
Connection to TSSC is broken. - HYDIN0716I (OP0716)
High packet loss occurred on the connection from TS7700 to TSSC. - HYDIN0717I (OP0717)
TSSC call home is in locked state. - HYDIN0718I (OP0718)
TSSC not communicating with external network. - HYDIN0719W (OP0719)
TSSC tssc bad port port is Down or in unknown state. - HYDIN0720E (OP0720)
Both TSSC ports are down or in unknown state. - HYDIN0721W (OP0721)
TSSC virtual interface Interface is not configured properly. - HYDIN0722W (OP0722)
TSSC IP address: IP is responding intermittently. - HYDIN0723E (OP0723)
TSSC IP address: IP is not responding. - HYDIN0724E (OP0724)
The connection to Adapter adapter link is not UP. Has not been UP for up to Downtime minutes. - HYDIN0725W (OP0725)
Adapter Adapter link is experiencing a high level of CRC errors. - HYDIN0726W (OP0726)
Adapter Adapter link is experiencing a high level of collisions. - HYDIN0727W (OP0727)
Ping test to address Address failed. The system has been in this condition for up to Downtime minutes. - HYDIN0728W (OP0728)
Ping test to address Address has an excessive packet loss. Has been in this condition for up to Downtime minutes. - HYDIN0729W (OP0729)
The connection to Adapter adapter link is not UP. Has not been UP for up to DownTime minutes. - HYDIN0730W (OP0730)
Call Home is currently disabled, - HYDIN0731W (OP0731)
The number of CRC errors is close to the threshold. - HYDIN0732E (OP0732)
The number of CRC errors has exceeded the threshold. - HYDIN0733W (OP0733)
Encryption Key Server EKMname:EKMport is not connected. - HYDIN0734W (OP0734)
Stand-alone system has GRID IP address configured. - HYDIN0735W (OP0735)
Virtual interface for MI is not correctly configured. - HYDIN0736W (OP0736)
Traffic on the external virtual interface is being redirected through an alternate path. - HYDIN0737E (OP0737)
Internal configuration for ordering name resolution has the incorrect look-up order for hosts. - HYDIN0738W (OP0738)
NTP Server has been unavailable for more than 30 minutes. - HYDIN0739E (OP0739)
NTP Server has been unavailable for more than unavailable minutes. - HYDIN0740E (OP0740)
Invalid configuration found in Domain Name Protocol file. - HYDIN0741E (OP0741)
Invalid configuration found in routing table. - HYDIN0742W (OP0742)
Path path in the customer network is down. - HYDIN0743E (OP0743)
Both ethernet paths to the external network are down. - HYDIN0744W (OP0744)
Performance settings for storage related devices are not set correctly. - HYDIN0745E (OP0745)
Problems found with mirrored disks (hdiskX and hdiskY). - HYDIN0746E (OP0746)
Disk: hdiskX was found on state: state. - HYDIN0747W (OP0747)
Configured memory size is: MemoryVPDMB, and the expected memory size is: CurrentMemoryMB. - HYDIN0748I (OP0748)
A problem was detected with the DVD-RAM in the system. - HYDIN0749E (OP0749)
Both switches must be configured with the same type (internal or external). - HYDIN0750E (OP0750)
Fibre Channel communication error. - HYDIN0751E (OP0751)
Fibre Channel hardware error. - HYDIN0752W (OP0752)
Fan or Power Supply failure detected in the server. - HYDIN0753W (OP0753)
PCI slot failure detected in the server. - HYDIN0754W (OP0754)
SPCN failure detected in the system. - HYDIN0755W (OP0755)
A sysplanar failure was detected. The reported system reference code (SRC) is: SRC. - HYDIN0756E (OP0756)
Adapter: Adapter is in status: Status. - HYDIN0757E (OP0757)
Unable to communicate with the Adapter I/O adapter card. - HYDIN0758E (OP0758)
Unable to communicate with the Adapter I/O drawer. - HYDIN0759W (OP0759)
A problem was found on the volume group or file system: VG, problem reported is: Issue. - HYDIN0760W (OP0760)
File system: FS, is using Space% of its available space. - HYDIN0761E (OP0761)
File system: FS, is using Space% of its available space. - HYDIN0762I (OP0762)
DVD is having problems; the reported operation is: DVD. - HYDIN0763I (OP0763)
System health checks were placed in skip mode. Call Home has been temporarily disabled. - HYDIN0764W (OP0764)
The tape drive device rmt device with serial number: deviceSN is shown as device state in the cluster. - HYDIN0765E (OP0765)
The power supply/fan assembly Location in enclosure Enclosure Number has failed or has been removed. Disk model: Disk Model - HYDIN0766E (OP0766)
Environmental service module (ESM) canister ESM ID in the expansion Expansion ID has failed or been removed, FRU: FRU. Disk model: Disk Model - HYDIN0767W (OP0767)
The link link number to host adapter ficon adapter is unavailable. - HYDIN0768I (OP0768)
Physical volume volser already exists. Duplicate physical volumes cannot be inserted. - HYDIN0769W (OP0769)
Unable to retrieve primary and secondary cache IP values from VPD for cache string: strNum. - HYDIN0770W (OP0770)
Cache controller for string: Snum, in slot: ctrlrSlot is in the ctrlrState state. - HYDIN0771W (OP0771)
The status of the cache controller: slot for string: string is unknown. - HYDIN0772W (OP0772)
The status of the battery for controller: slot, in string: string, is degraded. - HYDIN0773W (OP0773)
Adapter adapter path to cache, for string: Snum is inactive. - HYDIN0774W (OP0774)
Unable to detect a controller connected to adapter adapter, for string: Snum. - HYDIN0775W (OP0775)
Unable to find the link to the cache controller for string: string. - HYDIN0776W (OP0776)
Only one link to cache controller found for string: Snum. - HYDIN0777W (OP0777)
All of the spare disks in the string are missing. - HYDIN0778W (OP0778)
Unable to retrieve information about spare disks. - HYDIN0779W (OP0779)
Number of spare disks found is disks when the expected number is expected. - HYDIN0780E (OP0780)
One or more processes for the Hnode are not running. - HYDIN0781W (OP0781)
An error occurred when retrieving Grid information from VPD. - HYDIN0782W (OP0782)
Physical Library reported: state status. - HYDIN0783E (OP0783)
Unable to retrieve physical library state. - HYDIN0784W (OP0784)
A tape drive mismatch has been detected. The tape drives on the Virtual Library are not the same as in Physical Library. - HYDIN0785W (OP0785)
Expected expectedLinks grid links for this configuration, but found only foundLinks links. - HYDIN0786E (OP0786)
The TS7700 does not have enough sunset physical drives to read active data from sunset media. - HYDIN0787W (OP0787)
AOTM is unable to communicate with the local TSSC. - HYDIN0788W (OP0788)
AOTM is unable to communicate with the remote TSSC of node node. - HYDIN0789W (OP0789)
AOTM is unable to communicate with the remote node node. - HYDIN0790E (OP0790)
A memory leak has been detected. - HYDIN0791W (OP0791)
Disk array array for string: sNum does not support encryption. - HYDIN0792W (OP0792)
Disk array array for string: sNum is not encrypted. - HYDIN0793W (OP0793)
Disk at enclosure enc, slot slot does not support encryption. - HYDIN0794W (OP0794)
Imbalance in SMFS detected. - HYDIN0795W (OP0795)
The grid link adapter is running at currntSpd Mbps, but the expected speed is xpctdSpd Mbps. - HYDIN0796W (OP0796)
Unable to query the Grid network adapters. - HYDIN0797W (OP0797)
HDM inter-cluster heartbeats are taking longer than expected. - HYDIN0798W (OP0798)
The system is running on currentCPU CPUs, when the expected number of CPUs are expectedCPU. - HYDIN0799W (OP0799)
The system is running on currentCores CPU cores, when the expected number of CPU cores are expectedCores. - HYDIN0800W (OP0800)
The router firmware level is actualValue, but the expected level is expectedValue. - HYDIN0801W (OP0801)
The router ROM level is actualValue, but the expected level is expectedValue. - HYDIN0802W (OP0802)
Both the Active and Standby Library Managers are offline. - HYDIN0803W (OP0803)
The Active Library Manager is offline. - HYDIN0804W (OP0804)
Invalid configuration found in ordering name resolution file. - HYDIN0805W (OP0805)
Could not find hdisk in the list of diskType Disks on this system. - HYDIN0806E (OP0806)
At least one vital process for Vnode is not running. - HYDIN0807W (OP0807)
Unable to retrieve the information about Logical Devices. - HYDIN0808W (OP0808)
The number of logical devices is logicalDevs, number of tape daemons is tapeDaemons. - HYDIN0809W (OP0809)
AOTM is enabled, but the cluster detected errors. - HYDIN0810I (OP0810)
A scratch sunset physical volume volser was inserted into the library that the TS7700 cannot use. - HYDIN0811W (OP0811)
The communication to the External Key Server for Cache is down. - HYDIN0812E (OP0812)
At least one vital process for Vnode is not running. - HYDIN0813W (OP0813)
The state for proxy ip ip is in state (state) The state: 0 is Offline 1 is Unknown - HYDIN0814W (OP0814)
Fibre Channel switch switch FW level is downlevel: fw. - HYDIN0815W (OP0815)
All paths in the PRI switch are down. - HYDIN0816W (OP0816)
All paths in the ALT switch are down. - HYDIN0817E (OP0817)
Problems found with mirrored disk hdiskX. - HYDIN0818E (OP0818)
Problems found with disks in rootvg volume group. - HYDIN0819W (OP0819)
Disk pool array for string: sNum does not support encryption. - HYDIN0820W (OP0820)
Disk pool array for string: sNum is not encrypted. - HYDIN0821W (OP0821)
Mismatched drives exist in a cache disk pool. Disk model: Disk Model - HYDIN0822E (OP0822)
Failed Disk pool diskpool in string: sNum - HYDIN0823W (OP0823)
String: sNum, Disk pool diskpool with preservation capacity of capacity drives, is now using used. Another drive failure will cause a Check1 process. - HYDIN0824E (OP0824)
String: sNum, Failed drives exist in a cache disk pool. Disk model: Disk Model - HYDIN0825E (OP0825)
Fibre Channel communication error to both switches. - HYDIN0826E (OP0826)
I/O Drawer Adapter is reporting error(s): error - HYDIN0827E (OP0827)
Fiber switch hardware issues found in path(S). - HYDIN0828E (OP0828)
Communication error in the path in between the TS7700 and the fiber switch. - HYDIN0829E (OP0829)
Failed Disk array array in string: sNum
Parent topic: Reference