Management interface events
Use this section to locate additional information about TS7700 Management Interface event messages. Codes associated with these messages begin with the identifier HYDIN.
Expand the Management interface events parent topic in the left navigation pane to view the complete list of HYDIN event codes.
- HYDIN0000I
- HYDIN0003I
The I/O station is full. - HYDIN0004I
The virtual library is full. - HYDIN0017W
A load or unload failure has occurred on device: device serial number. - HYDIN0045I
VOLSER cartridge label cannot be removed from its home location. - HYDIN0048W
A VOLSER VOLSER has an incorrect media type on the external label. - HYDIN0066I
One or more volumes have been inserted into the library and marked unassigned. - HYDIN0100I
A read-only physical volume stacked volume cartridge label has been ejected. - HYDIN0101E
The cluster is out of empty physical volumes. - HYDIN0102W
A physical volume has a label error. Internal: stacked volume label, External: stacked volume label - HYDIN0103E
A permanent, non-recoverable tape volume cache error has occurred. - HYDIN0106I
Virtual volume virtual volume VOLSER was only partially read. - HYDIN0107W
Virtual volume virtual volume VOLSER was not fully recovered from damaged physical volume stacked volume VOLSER. - HYDIN0112W
Device serial number device serial number has been made offline and/or unavailable by the TS7700 Engine with a reason code of reason code. - HYDIN0115I
The cluster attempted unsuccessfully to eject a damaged physical volume stacked volume VOLSER. - HYDIN0120I
Mount of virtual volume virtual volume VOLSER failed because physical volume stacked volume VOLSER is misplaced. (reason code=error code) - HYDIN0121W
Mount of virtual volume virtual volume VOLSER failed because physical volume stacked volume VOLSER is inaccessible. - HYDIN0122W
Mount of virtual volume virtual volume VOLSER located on physical volume stacked volume VOLSER failed. (reason code=error code) - HYDIN0123I
Physical volume stacked volume VOLSER is in read-only status due to successive media errors. - HYDIN0124W
Physical volume cartridge label is unavailable. - HYDIN0127E
An invalid mixture of physical drive types was detected. - HYDIN0128E
The TS7700 Engine does not have enough physical drives to continue operation. - HYDIN0130I
Physical volume physical stacked volume VOLSER failed scratch mount. Its label cannot be read and the tape must be re-initialized. - HYDIN0134I
Physical volume stacked volume VOLSER is write-protected. - HYDIN0135I
The TS7700 unsuccessfully attempted to eject write-protected physical volume stacked volume VOLSER. - HYDIN0136I
Physical volume stacked volume VOLSER was moved to category FF08 due to unrecovered active data. - HYDIN0138E
The common scratch pool (Pool 00) is out of media type media physical volumes. - HYDIN0139E
Storage Pool storage pool number is out of scratch physical volumes. - HYDIN0140I
VOLSER VOLSER could not be moved from Storage Pool source pool number to Storage Pool target pool number. Error code = error code. - HYDIN0144W
Eject failed on physical volume VOLSER that contains active data. Error code = error code. - HYDIN0149E
Storage Pool storage pool number is out of write compatible physical scratch volumes. - HYDIN0150I
The physical volume VOLSER has become degraded. This condition is the result of a media condition report. - HYDIN0152I
Active data on ejected physical volume VOLSER needs to be recovered. - HYDIN0153I
Physical volume stacked volume VOLSER is misplaced. - HYDIN0164I
The TS7700 Engine has initiated auto removal of volumes on this disk-only cluster. - HYDIN0165I
One or more non-writable physical volumes were found. - HYDIN0166I
Copy Export did not export physical volume VOLSER because of an incorrect format. - HYDIN0167I
Unsupported media (for example: JA, JJ) is set for First Media, Second Media, or both for Physical Volume Pool(s): pool numbers. - HYDIN0168I
One or more unsupported empty media has been found and cannot be used by the installed tape drives. - HYDIN0169E
The cache type is out of cache space. The total used, space usage TiB, is less than 1 TiB from the total cache space or less than 5% below the total cache space, total space TiB. - HYDIN0170W
The cache type has limited cache free space. The total used, space usage TiB, is less than 3 TiB from the total cache space or less than 15% of total cache space, total space TiB. - HYDIN0171W
Unsupported scratch media of type media type were inserted into the library. - HYDIN0172I
Automatic removal of logical volumes on this cluster has been disabled due to a small cache resident-only partition size. - HYDIN0173I
Automatic removal of logical volumes on this cluster has been enabled because the cache resident-only partition size is now sufficient. - HYDIN0200W
The local cluster is operating in immediate copy mode and at least one copy did not finish prior to the completion of the Rewind/Unload command. - HYDIN0201I
All immediate deferred copy operations are complete. - HYDIN0202W
One or more volumes opened as part of a synchronous mode copy operation did not synchronize completely across both clusters. - HYDIN0203I
Synchronization across both clusters has completed for all volumes that were in the synchronous deferred state. - HYDIN0204W
Copy operations for the local cluster are disabled by the system. - HYDIN0205I
The system has enabled copy operations at the local cluster. - HYDIN0206I
Copy operations for the local cluster are disabled by the host. - HYDIN0207I
Copy operations for the local cluster are enabled by the host. - HYDIN0310I
The data class data class was automatically created with the default actions for volume virtual volume VOLSER. - HYDIN0311I
The Storage Class storage class was automatically created with the default actions for volume virtual volume VOLSER. - HYDIN0312I
The Management Class management class was automatically created with the default actions for volume virtual volume VOLSER. - HYDIN0313I
The Storage Group storage group was automatically created with the default actions for volume virtual volume VOLSER. - HYDIN0314I
The inhibit create command was ignored and one or more constructs were automatically created with the default actions for volume virtual volume VOLSER as a result of an imbalance of defined SMS constructs across the Domain. - HYDIN0315I
The maximum number of defined constructs has been reached. An imbalance of defined SMS constructs across the domain has occurred. Default constructs were assigned for volume virtual volume VOLSER. - HYDIN0316E
The TS7700 Engine has detected corrupted tokens for one or more virtual volumes. - HYDIN0409I
The volume hold function was disabled for scratch category scratch category. - HYDIN0410I
The hold/expire time has been changed to hours hours for scrath category scratch category. - HYDIN0411I
A fast-ready attribute was deleted for category scratch category. - HYDIN0428W
The 3584 library reported a hardware error (error data). Contact your IBM service representative. - HYDIN0433I
The Send Interventions to Host Console setting on the Events panel has been turned on. - HYDIN0434I
The Send Interventions to Host Console setting on the Events panel has been turned off. - HYDIN0439W
The TS7700 lost communication with the primary Encryption Key Server. - HYDIN0440W
The TS7700 lost communications with the alternate Encryption Key Server. - HYDIN0442I
Physical volume stacked volume VOLSER is inaccessible. - HYDIN0443I
The virtual tape library has detected an inconsistency with the physical tape library. - HYDIN0444W
LM PC has not been rebooted in 6 months. - HYDIN0445W
The primary Encryption Key Server was set to UNAVAILABLE. - HYDIN0446W
The alternate Encryption Key Server was set to UNAVAILABLE. - HYDIN0448I
More than error quantity errors were encountered for physical volume stacked volume VOLSER. - HYDIN0449I
Pool storage pool number has physical volumes of the wrong media class. - HYDIN0450I
The media type of VOLSER VOLSER does not match its VOLSER range. The VOLSER was not assigned to a cluster. - HYDIN0451I
Encryption is enabled. No Encryption Key Servers are configured. - HYDIN0452W
Encryption Key Server error Encryption Key Server error number prevented device drive serial number from encrypting data in storage pool storage pool number. - HYDIN0453W
Device drive serial number could not append encrypted data to cartridge cartridge volser (Encryption Key Server error Encryption Key Server error number). - HYDIN0454W
Device drive serial number could not decrypt data from cartridge cartridge volser (Encryption Key Server error Encryption Key Server error number). - HYDIN0455W
Device device serial number is not in 3592 E05 Native mode. The Device was made unavailable. - HYDIN0456W
Encryption is enabled on the virtual tape library. Device device serial number is not enabled for system-managed encryption. - HYDIN0468W
The 3494 Library Manager has an event. - HYDIN0469W
The 3494 Library Manager is in a degraded state. - HYDIN0470I
Delete Expire capability has been disabled. - HYDIN0471E
The Field Microcode Replacement tape stacked volume VOLSER cannot be used as a data cartridge. - HYDIN0472I
The database backup to physical volume VOLSER failed during the Copy Export operation as a result of a media error. - HYDIN0473I
A media error occurred during the Copy Export operation and the physical volume VOLSER has been ejected. The medium may be degraded, and should not be reused in an export pool. - HYDIN0474I
The Copy Export operation did not export physical volume VOLSER because the primary copy for virtual volume VOLSER is currently unavailable. - HYDIN0475I
Copy Export did not export virtual volume VOLSER because it was not able to premigrate the volume to the export pool. - HYDIN0476I
The event was cleared automatically. - HYDIN0477I
The event was cleared by user. - HYDIN0480I
Service Call Home will be initiated. - HYDIN0481I
Service Call Home was initiated. - HYDIN0482I
Service Call Home was initiated with PMR number PMR number. - HYDIN0483E
A permanent cache problem was encountered. - HYDIN0484E
A permanent cache problem was encountered. - HYDIN0485E
A 3956-CC6 permanent check was encountered. - HYDIN0486E
A CHECK1 condition was encountered. - HYDIN0487E
An adapter microcode CHECK1 condition occurred. - HYDIN0488E
A channel event occurred. - HYDIN0489E
An undetermined error occurred. - HYDIN0490E
An operator notification occurred. - HYDIN0491E
A microcode exception occurred in the ATL daemon. - HYDIN0492E
An undetermined error occurred. - HYDIN0493E
An informational message was presented by CU. - HYDIN0494E
An environmental problem has occurred. - HYDIN0495E
A microcode exception occurred in the tape daemon. - HYDIN0496E
The tape daemon detected a CRC error. - HYDIN0497E
A microcode exception occurred in the tape daemon. - HYDIN0498E
A microcode exception occurred in the BATE daemon. - HYDIN0499I
An error was detected and a Service Call Home has been generated. The call home includes the following SIM(s): SIMID-RESOURCE-REF_CODES SIM - HYDIN0500I
The times displayed by the local and remote clusters remote cluster differ by more than 5 seconds. - HYDIN0510I
user name logged into the Web interface. - HYDIN0511I
user name logged out of the Web interface. - HYDIN0512I
User action the setting to send future events to host. - HYDIN0514I
Custom Role role has been changed. - HYDIN0515I
SNMP settings have changed.\n Values are:\n SNMP Version: version\n Enable SNMP Traps: enabled\n Trap Community Name: community\n - HYDIN0516I
Stand-alone mount was initiated for volume var0 on device var1. - HYDIN0517I
Stand-alone demount was initiated on device var0. - HYDIN0518I
Node var0 has been shut down. - HYDIN0519I
Custom Role role has been created. - HYDIN0520I
Custom Role role has been deleted. - HYDIN0521I
The security settings for local authentication have changed. \n \nLocal Account Expiration: Enabled. \nThe account will expire if the password is not changed in time days. - HYDIN0522I
The security settings for local authentication have changed. \n \nLocal Account Expiration: Disabled. - HYDIN0523I
The security settings for local authentication have changed. \n \nLocal Account Lock: Enabled. \nThe account will be locked after attempts unsuccessful attempts to enter the password. - HYDIN0524I
The security settings for local authentication have changed. \n \nLocal Account Lock: Disabled. - HYDIN0525E
A TAPE DRIVE FAILURE has occurred - HYDIN0526E
A FibrePath, FibreSwitch, or FibreInterface error has occurred. - HYDIN0527I
Stand-alone mount for volume var0 on device var1 completed successfully. - HYDIN0528I
Stand-alone demount for volume var0 on device var1 completed successfully. - HYDIN0529W
Stand-alone mount for volume var0 on device var1 failed with error code var2. - HYDIN0530W
Stand-alone demount for volume var0 on device var1 failed with error code var2. - HYDIN0531W
The network connection on grid port port number with IP address: IP address experienced a possible loss of connectivity. - HYDIN0532E
The network connection on grid port port number with IP address: IP address is not responding. - HYDIN0533I
The connection between the local cluster and the remote cluster cluster with remote port remote port and IP address: remote cluster IP address was interrupted. - HYDIN0534W
The connection between the local cluster and the remote cluster cluster with remote portremote port and IP address: remote cluster IP address of the remote cluster is losing packets, or the connection was unavailable. - HYDIN0535E
The connection of local cluster to remote cluster cluster with remote portremote port and IP address: remote cluster IP address of the remote cluster, was not available. - HYDIN0536E
The link to remote cluster: remote cluster with IP address: remote cluster IP address is in the offline state. - HYDIN0537I
The connection of local cluster to remote cluster cluster with remote portremote port and remote IP address: remote cluster IP address was unavailable for a brief time or because the local cluster was unable to retrieve the status of the remote adapter. - HYDIN0538W
The connection of local cluster to remote cluster cluster with remote port remote port and remote IP address: remote cluster IP address was not available, because the local cluster reports the status of the remote adapter as not available. - HYDIN0539E
The connection of local cluster to remote cluster cluster with remote port remote port and IP address: remote cluster IP address of the remote cluster was not available, because the state of the remote adapter appears as Failed. - HYDIN0540E
The link to remote cluster: remote cluster With IP address: remote cluster IP address is in the offline state. NTC (Network Traffic Controller) reports link state: link state - HYDIN0541W
The link to gateway IP gateway IP address is degraded. - HYDIN0542E
The link to gateway IP gateway IP address has failed. - HYDIN0543W
The primary and alternate grid adapters have different speeds:\n Primary var0 link speed is: primary link speed\n Alternate var2 link speed is: alternate link speed - HYDIN0544E
The primary grid Ethernet adapter var0 is down. - HYDIN0545E
The alternate grid Ethernet adapter var0 is down. - HYDIN0546I
Could not retrieve the date on cluster cluster. - HYDIN0547E
A time synchronization failure was detected between cluster var0 and Cluster var1. - HYDIN0548W
There is no communication with one or more clusters in the Grid. - HYDIN0549W
One or more clusters in the Grid are in Service status. - HYDIN0550I
Service Call Home, TSSC was unable to generate a PMR number - HYDIN0551E
A permanent cache problem was encountered. - HYDIN0552E
A temporary cache problem was encountered. - HYDIN0553E
The cache has an unreadable sector. - HYDIN0554E
A cache power supply has failed. - HYDIN0555E
A cache power or fan assembly has failed. - HYDIN0556E
The cache has lost redundancy. - HYDIN0557E
A problem exists with the cabling or drive path inside the cache enclosure. - HYDIN0558E
A cache component has failed or been removed. - HYDIN0559E
A cache controller has failed or been removed. - HYDIN0560E
An environmental service module (ESM) canister in the cache has failed or been removed. - HYDIN0561E
A cache drive is missing. - HYDIN0562E
A cache drive is in a degraded state. - HYDIN0563E
A cache disk has reported errors. - HYDIN0564E
A cache RAID array has failed drives. - HYDIN0565E
An unsupported number of drive enclosures exists on a cache loop. - HYDIN0566E
The reported data rate of a cache drive channel is outside the expected range. - HYDIN0567E
The data rate could not be obtained on a drive channel for the cache. - HYDIN0568E
An incorrect number of enclosures exists on a cache loop. - HYDIN0569E
The number of enclosures on a cache loop cannot be determined. - HYDIN0570E
Mismatched drives exist in a cache array. - HYDIN0571E
Disk operation in the cache is degraded. - HYDIN0572I
Network errors were detected while connecting to the cache. - HYDIN0573E
An unreadable sector exists in the cache. - HYDIN0574E
A parity error occurred in the cache. - HYDIN0575E
A cache media error occurred. - HYDIN0576I
A temporary cache problem was encountered. - HYDIN0577E
The cache has an unreadable sector. - HYDIN0578E
A cache power supply has failed. - HYDIN0579E
A cache power or fan assembly has failed. - HYDIN0580E
The cache has lost redundancy. - HYDIN0581E
A problem exists with the cabling or drive path inside the cache enclosure. - HYDIN0582E
A cache component has failed or been removed. - HYDIN0583E
A cache controller has failed or been removed. - HYDIN0584E
An environmental service module (ESM) canister in the cache has failed or been removed. - HYDIN0585E
A cache drive is missing. - HYDIN0586E
A cache drive is in a degraded state. - HYDIN0587E
A cache disk has reported errors. - HYDIN0588E
A cache RAID array has failed drives. - HYDIN0589E
An unsupported number of drive enclosures exists on a cache loop. - HYDIN0590E
The reported data rate of a cache drive channel is outside the expected range. - HYDIN0591E
The data rate could not be obtained on a drive channel for the cache. - HYDIN0592E
An incorrect number of enclosures exists on a cache loop. - HYDIN0593E
The number of enclosures on a cache loop cannot be determined. - HYDIN0594E
Mismatched drives exist in a cache array. - HYDIN0595E
Disk operation in the cache is degraded. - HYDIN0596E
Network errors were detected while connecting to the cache. - HYDIN0597E
An unreadable sector exists in the cache. - HYDIN0598E
A parity error occurred in the cache. - HYDIN0599E
A cache media error occurred. - HYDIN0600E
A temporary cache problem was encountered. - HYDIN0601E
The cache has an unreadable sector. - HYDIN0602E
A cache power supply has failed. - HYDIN0603E
A cache power or fan assembly has failed. - HYDIN0604E
The cache has lost redundancy. - HYDIN0605E
A problem exists with the cabling or drive path inside the cache enclosure. - HYDIN0606E
A cache component has failed or been removed. - HYDIN0607E
A cache controller has failed or been removed. - HYDIN0608E
An environmental service module (ESM) canister in the cache has failed or been removed. - HYDIN0609E
A cache drive is missing. - HYDIN0610E
A cache drive is in a degraded state. - HYDIN0611E
A cache disk has reported errors. - HYDIN0612E
A cache RAID array has failed drives. - HYDIN0613E
An unsupported number of drive enclosures exists on a cache loop. - HYDIN0614E
The reported data rate of a cache drive channel is outside the expected range. - HYDIN0615E
The data rate could not be obtained on a drive channel for the cache. - HYDIN0616E
An incorrect number of enclosures exists on a cache loop. - HYDIN0617E
The number of enclosures on a cache loop cannot be determined. - HYDIN0618E
Mismatched drives exist in a cache array. - HYDIN0619E
Disk operation in the cache is degraded. - HYDIN0620E
Network errors were detected while connecting to the cache. - HYDIN0621E
An unreadable sector exists in the cache. - HYDIN0622E
A parity error occurred in the cache. - HYDIN0623E
A cache media error occurred. - HYDIN0624E
An error was detected in the disk cache. - HYDIN0625E
A system reboot interrupted a call home. - HYDIN0626I
One or more issues on the system have persisted for longer than 48 hours. - HYDIN0627E
There is a problem with network communication required for autonomic ownership takeover. - HYDIN0628E
The cache controller is not configured. - HYDIN0629E
The cache file system is inefficiently allocating its available space. - HYDIN0630E
There is a problem with the network fail over code. - HYDIN0631E
The error detection feature has restarted five times in 24 hours. - HYDIN0632E
The available memory is not configured correctly. - HYDIN0633E
A CPU has failed. - HYDIN0634E
Port 0 on the customer network has failed. - HYDIN0635E
Port 1 on the customer network has failed. - HYDIN0636E
Both Ethernet routers have failed. - HYDIN0637E
The primary Ethernet router has failed. - HYDIN0638E
The alternate Ethernet router has failed. - HYDIN0639E
The Network Time Protocol (NTP) server is not responding. - HYDIN0640E
A port in an Ethernet router has failed. - HYDIN0641E
A port in an Ethernet router shows increasing errors. - HYDIN0642E
Communication between the disk cache and the primary switch has failed. - HYDIN0643E
Communication between the disk cache and the alternate switch has failed. - HYDIN0644E
One or more arrays are not encrypted. - HYDIN0645I
This is a cache Call Home test. - HYDIN0646W
Encryption is enabled on the virtual tape library. Device device serial number is not encryption-capable. The device was made unavailable. - HYDIN0647E
Host adapter adapter is offline. - HYDIN0648I
The link link number to host adapter ficon adapter is unavailable. - HYDIN0649E
No IBM media changer devices were found on the system. - HYDIN0650W
The system identified number of smc devices IBM media changer devices. This is an incorrect number of devices. - HYDIN0651I
The IBM media changer smc device name is in an unknown state. - HYDIN0652I
The fibre channel adapter for tape interface interface number cannot be identified. - HYDIN0653I
The drive name drive name does not match port port name. - HYDIN0654E
Drives could not be configured on a 3590 or 3592 tape drive. - HYDIN0655W
The physical tape SCSI device rmt device is in the state: device state. - HYDIN0656E
Primary and alternate paths for tape SCSI device rmt device are unavailable. - HYDIN0657W
The tape drive device rmt device is shown as device state in the cluster. - HYDIN0658I
The tape drive device rmt device is in the state device state. - HYDIN0659W
The path primary or alternate for tape drive rmt device name is unavailable. - HYDIN0660E
Both primary and alternate paths for tape drive device rmt device name are unavailable. - HYDIN0661I
Tape device rmt device name is in an unknown state. - HYDIN0662I
The path Primary or Alternate to tape device rmt device name is disabled. - HYDIN0663E
No tape drives were found in the system. - HYDIN0664W
All paths on the primary or alternate lower channel protocol interface failed. - HYDIN0665E
All paths on the primary and alternate lower fibre channel protocol interface failed. - HYDIN0666E
The primary and alternate paths for rmt device name on the lower fibre channel protocol interface failed. - HYDIN0667W
The tape SCSI device path rmt device name on lower fibre channel protocol interface failed. - HYDIN0668I
The state of the drive device name on the Library type model could not be obtained. - HYDIN0669I
The tape drive device name is not available to the phyiscal library Library type model. - HYDIN0670I
This system contains both E05 drives in native mode and J1A drives. - HYDIN0671I
All drives are reported as in the busy state. - HYDIN0672I
The world wide node name (WWNN) could not be obtained for drive device name. - HYDIN0673I
The physical volume status could not be obtained. - HYDIN0674I
No physical volumes are found on the system. - HYDIN0675I
The physical volume pool status could not be obtained. - HYDIN0676W
Physical volume pool pool name is out of scratch volumes. - HYDIN0677I
Volume volume name reports a state volume state with access in access status status. - HYDIN0678I
LDAP server connection (IP) experienced a loss of connectivity. - HYDIN0679E
LDAP server connection (IP) is not responding. - HYDIN0680E
LDAP server service is down. IP:IP Port:Port Number - HYDIN0681W
LDAP server connection is not correctly configured. IP: IP Port:port number - HYDIN0682I
Authentication server AuthServer id connection (IP) experienced a loss of connectivity. - HYDIN0683E
Authentication server AuthServer id service is down. IP:IP Port:Port number - HYDIN0684W
The connection to authentication server AuthServer id is not correctly configured. IP: IP Port:Port number - HYDIN0687E
An unknown cache problem was encountered. Disk model: Disk Model. - HYDIN0688E
The cache has an unreadable sector error. Disk model: Disk Model. - HYDIN0689E
A cache power supply has failed. Disk model: Disk Model. - HYDIN0690E
A loss of redundancy has occurred in cache. Disk model: Disk Model - HYDIN0691E
A problem exists with the cabling or drive path inside the cache enclosure. Disk model: Disk Model. - HYDIN0692E
A DDM is missing. Disk model: Disk Model - HYDIN0693E
A cache controller has failed or been removed. Disk model: Disk Model - HYDIN0694E
An environmental service module (ESM) canister in the cache has failed or been removed. Disk model: Disk Model - HYDIN0695E
A cache component has failed or been removed. Disk model: Disk Model - HYDIN0696E
Failed drives exist in a cache RAID array. Disk model: Disk Model - HYDIN0697E
Mismatched drives exist in a cache array. Disk model: Disk Model - HYDIN0698E
Disk operation in the cache is degraded. Disk model: Disk Model - HYDIN0699W
Network errors were detected while connecting to the cache. Disk model: Disk Model - HYDIN0700E
An unsupported number of drive enclosures exists on a cache loop. Disk model: Disk Model - HYDIN0701E
The reported data rate of a cache drive channel is outside the expected range. Disk model: Disk Model - HYDIN0702E
The data rate could not be obtained on a drive channel for the cache. Disk model: Disk Model - HYDIN0703E
An incorrect number of enclosures exists on a cache loop. Disk model: Disk Model - HYDIN0704E
The number of enclosures on a cache loop cannot be determined. Disk model: Disk Model - HYDIN0705E
An unreadable sector exists in the cache. Disk model: Disk Model - HYDIN0706E
A disk cache parity mismatch error occurred in the cache. Disk model: Disk Model - HYDIN0707E
A cache media error occurred. Disk model: Disk Model - HYDIN0708E
A cache power or fan assembly has failed. Disk model: Disk Model - HYDIN0709E
A cache drive is in a degraded state. Disk model: Disk Model - HYDIN0710E
A cache disk has reported errors. Disk model: Disk Model - HYDIN0711E
The cache battery is in a degraded state. Disk model: Disk Model - HYDIN0712E
The cache controller is in a degraded state. Disk model: Disk Model - HYDIN0713E
Information for this event cannot be displayed on this cluster. - HYDIN0714W
A cache DDM has failed. String: string, enclosure: enclosure, slot: slot. The disk model is: disk model. - HYDIN0715I
Connection to TSSC is broken. - HYDIN0716I
High packet loss occurred on the connection from TS7700 to TSSC. - HYDIN0717I
TSSC call home is in locked state. - HYDIN0718I
TSSC not communicating with external network. - HYDIN0719W
TSSC tssc bad port port is Down or in unknown state. - HYDIN0720E
Both TSSC ports are down or in unknown state. - HYDIN0721W
TSSC virtual interface Interface is not configured properly. - HYDIN0722W
TSSC IP address: IP is responding intermittently. - HYDIN0723E
TSSC IP address: IP is not responding. - HYDIN0724E
The connection to Adapter adapter link is not UP. Has not been UP for up to Downtime minutes. - HYDIN0725W
Adapter Adapter link is experiencing a high level of CRC errors. - HYDIN0726W
Adapter Adapter link is experiencing a high level of collisions. - HYDIN0727W
Ping test to address Address failed. The system has been in this condition for up to Downtime minutes. - HYDIN0728W
Ping test to address Address has an excessive packet loss. Has been in this condition for up to Downtime minutes. - HYDIN0729W
The connection to Adapter adapter link is not UP. Has not been UP for up to DownTime minutes. - HYDIN0730W
Call Home is currently disabled, - HYDIN0731W
The number of CRC errors is close to the threshold. - HYDIN0732E
The number of CRC errors has exceeded the threshold. - HYDIN0733W
Encryption Key Server EKMname:EKMport is not connected. - HYDIN0734W
Stand-alone system has GRID IP address configured. - HYDIN0735W
Virtual interface for MI is not correctly configured. - HYDIN0736W
Traffic on the external virtual interface is being redirected through an alternate path. - HYDIN0737E
Internal configuration for ordering name resolution has the incorrect look-up order for hosts. - HYDIN0738W
NTP Server has been unavailable for more than 30 minutes. - HYDIN0739E
NTP Server has been unavailable for more than unavailable minutes. - HYDIN0740E
Invalid configuration found in Domain Name Protocol file. - HYDIN0741E
Invalid configuration found in routing table. - HYDIN0742W
Path path in the customer network is down. - HYDIN0743E
Both ethernet paths to the external network are down. - HYDIN0744W
Performance settings for storage related devices are not set correctly. - HYDIN0745E
Problems found with mirrored disks (hdiskX and hdiskY). - HYDIN0746E
Disk: hdiskX was found on state: state. - HYDIN0747W
Configured memory size is: MemoryVPDMB, and the expected memory size is: CurrentMemoryMB. - HYDIN0748I
A problem was detected with the DVD-RAM in the system. - HYDIN0749E
Both switches must be configured with the same type (internal or external). - HYDIN0750E
Fibre Channel communication error. - HYDIN0751E
Fibre Channel hardware error. - HYDIN0752W
Fan or Power Supply failure detected in the server. - HYDIN0753W
PCI slot failure detected in the server. - HYDIN0754W
SPCN failure detected in the system. - HYDIN0755W
A sysplanar failure was detected. The reported system reference code (SRC) is: SRC. - HYDIN0756E
Adapter: Adapter is in status: Status. - HYDIN0757E
Unable to communicate with the Adapter I/O adapter card. - HYDIN0758E
Unable to communicate with the Adapter I/O drawer. - HYDIN0759W
A problem was found on the volume group or file system: VG, problem reported is: Issue. - HYDIN0760W
File system: FS, is using Space% of its available space. - HYDIN0761E
File system: FS, is using Space% of its available space. - HYDIN0762I
DVD is having problems; the reported operation is: DVD. - HYDIN0763I
System health checks were placed in skip mode. Call Home has been temporally disabled. - HYDIN0764W
The tape drive device rmt device with serial number: deviceSN is shown as device state in the cluster. - HYDIN0765E
The power supply/fan assembly Location in enclosure Enclosure Number has failed or has been removed. Disk model: Disk Model - HYDIN0766E
Environmental service module (ESM) canister ESM ID in the expansion Expansion ID has failed or been removed, FRU: FRU. Disk model: Disk Model - HYDIN0767W
The link link number to host adapter ficon adapter is unavailable. - HYDIN0768I
Physical volume volser already exists. Duplicate physical volumes cannot be inserted. - HYDIN0769W
Unable to retrieve primary and secondary cache IP values from VPD for cache string: strNum. - HYDIN0770W
Cache controller for string: Snum, in slot: ctrlrSlot is in the ctrlrState state. - HYDIN0771W
The status of the cache controller: slot for string: string is unknown. - HYDIN0772W
The status of the battery for controller: slot, in string: string, is degraded. - HYDIN0773W
Adapter adapter path to cache, for string: Snum is inactive. - HYDIN0774W
Unable to detect a controller connected to adapter adapter, for string: Snum. - HYDIN0775W
Unable to find the link to the cache controller for string: string. - HYDIN0776W
Only one link to cache controller found for string: Snum. - HYDIN0777W
All of the spare disks in the string are missing. - HYDIN0778W
Unable to retrieve information about spare disks. - HYDIN0779W
Number of spare disks found is disks when the expected number is expected. - HYDIN0780E
One or more processes for the Hnode are not running. - HYDIN0781W
An error occurred when retrieving Grid information from VPD. - HYDIN0782W
Physical Library reported: state status. - HYDIN0783E
Unable to retrieve physical library state. - HYDIN0784W
A tape drive mismatch has been detected. The tape drives on the Virtual Library are not the same as in Physical Library. - HYDIN0785W
Expected expectedLinks grid links for this configuration, but found only foundLinks links. - HYDIN0786E
The TS7700 does not have enough sunset physical drives to read active data from sunset media. - HYDIN0787W
AOTM is unable to communicate with the local TSSC. - HYDIN0788W
AOTM is unable to communicate with the remote TSSC of node node. - HYDIN0789W
AOTM is unable to communicate with the remote node node. - HYDIN0790E
A memory leak has been detected. - HYDIN0791W
Disk array array for string: sNum does not support encryption. - HYDIN0792W
Disk array array for string: sNum is not encrypted. - HYDIN0793W
Disk at enclosure enc, slot slot does not support encryption. - HYDIN0794W
Imbalance in SMFS detected. - HYDIN0795W
The grid link adapter is running at currntSpd Mbps, but the expected speed is xpctdSpd Mbps. - HYDIN0796W
Unable to query the Grid network adapters. - HYDIN0797W
HDM inter-cluster heartbeats are taking longer than expected. - HYDIN0798W
The system is running on currentCPU CPUs, when the expected number of CPUs are expectedCPU. - HYDIN0799W
The system is running on currentCores CPU cores, when the expected number of CPU cores are expectedCores. - HYDIN0800W
The router firmware level is actualValue, but the expected level is expectedValue. - HYDIN0801W
The router ROM level is actualValue, but the expected level is expectedValue. - HYDIN0802W
Both the Active and Standby Library Managers are offline. - HYDIN0803W
The Active Library Manager is offline. - HYDIN0804W
Invalid configuration found in ordering name resolution file. - HYDIN0805W
Could not find hdisk in the list of diskType Disks on this system. - HYDIN0806E
At least one vital process for Vnode is not running. - HYDIN0807W
Unable to retrieve the information about Logical Devices. - HYDIN0808W
The number of logical devices is logicalDevs, number of tape daemons is tapeDaemons. - HYDIN0809W
AOTM is enabled, but the cluster detected errors. - HYDIN0810I
A scratch sunset physical volume volser was inserted into the library that the TS7700 cannot use. - HYDIN0811W
The communication to the External Key Server for Cache is down. - HYDIN0812E
At least one vital process for Vnode is not running. - HYDIN0813W
The state for proxy ip ip is in state (state) The state: 0 is Offline 1 is Unknown - HYDIN0814W
Fibre Channel switch switch FW level is downlevel: fw. - HYDIN0815W
All paths in the PRI switch are down. - HYDIN0816W
All paths in the ALT switch are down. - HYDIN0817E
Problems found with mirrored disk hdiskX. - HYDIN0818E
Problems found with disks in rootvg volume group. - HYDIN0819W
Disk pool array for string: sNum does not support encryption. - HYDIN0820W
Disk pool array for string: sNum is not encrypted. - HYDIN0821W
Mismatched drives exist in a cache disk pool. Disk model: Disk Model - HYDIN0822E
Failed Disk pool diskpool in string: sNum - HYDIN0823W
String: sNum, Disk pool diskpool with preservation capacity of capacity drives, is now using used. Another drive failure will cause a Check1 process. - HYDIN0824E
String: sNum, Failed drives exist in a cache disk pool. Disk model: Disk Model - HYDIN0825E
Fibre Channel communication error to both switches. - HYDIN0826E
I/O Drawer Adapter is reporting error(s): error - HYDIN0827E
Fiber switch hardware issues found in path(S). - HYDIN0828E
Communication error in the path in between the TS7700 and the fiber switch.
Parent topic: Reference