You might require to cable and understand the function of this feature. Use the following information to complete these tasks.

Review the disk drive modes and supported disk drive locations, as shown in Table 1. The following figure shows the disk drive locations for the 8248-L4T, 8408-E8D, or 9109-RMD.
Figure 1. Disk drive locations
Locations of disk drives
Table 1. Disk drive modes and supported disk drive locations
Disk drive mode SAS port card Adapter SAS cable Disk drive location
Dual RAID of internal drives None Integrated Dual RAID controller None D1, D2, D3, D4, D5, and D6
Dual RAID of internal and external drives SAS External Port feature (FC 1819) - SAS Cable Assembly for SAS Port Integrated Dual RAID controller
  • YI Cable (FC 3686) - System to SAS Enclosure, Single Controller/Dual Path 1.5 meter
  • YI Cable (FC 3687) - System to SAS Enclosure, Single Controller/Dual Path 3 meter
D1, D2, D3, D4, D5, and D6
Dual Split Backplane None
  • Integrated SAS controller (SAS A)
  • Integrated SAS controller (SAS B)
None
  • D1, D2, and D3
  • D4, D5, and D6
Triple Split Backplane SAS Internal Port feature (FC1815) - SAS Cable for triple split disk drive backplane
  • Integrated SAS controller (SAS A)
  • Integrated SAS controller (SAS B)
  • (FC 5901) - PCIe Dual-x4 SAS Adapter
AI Cable (FC 3679) - Adapter to Internal drive 1 meter
  • D1 and D4
  • D2 and D5
  • D3 and D6
The following information is for use after the FC 5901 SAS Storage Adapter is installed. Install the adapter and then return here. For instructions, see, PCI adapters.

You should also review the tasks in Before you begin if you have not already done so.

This feature allows you to split the internal disks in the system unit enclosure into groups which you can manage separately.
  1. Stop and power off the system if it is not already. For instructions, see Stopping the system or logical partition.
  2. Cable a single system unit enclosure by doing the following:
    1. Attach the cable to the SAS port on the rear bulkhead of the system unit enclosure to the top port in the SAS Storage Adapter, as shown in the following figure.
      Restriction: Internal disk drive sharing is only available when internal cable feature FC 1815 is installed from the DASD backplane to the read bulkhead of the system unit enclosure. Also, feature FC 5662 175 MB cache RAID - dual IOA enablement card must not be installed. The SAS Storage Adapter can be in any of the other slots that support it.
      Cabling a single drawer system.
    2. Secure any extra cable.
  3. Start the system. For instructions, see Starting the system or logical partition.
  4. Verify that the feature is installed and working. For instructions, see Verifying the installed part.
With this function installed, 2 of the 6 of the disks in the system enclosure can be managed by the SAS Storage Adapter.
Note: The Removable Media device is always controlled by a separate embedded SAS controller on the system planar.
Now, you can manage the disks as you would manage any other disks.


Send feedback Rate this page

Last updated: Thu, November 20, 2014