This is a primary PCI bus generated under a RIO adapter/HSL I/O bridge.
This bus can be in a system unit or I/O unit, and on some units this bus connects two FRUs.
| Model or expansion unit containing the failing item | Action |
|---|---|
| 510, 515, 520, 525, 550, OpenPower® 710, OpenPower 720, 570, 575 | Perform SYSBKPL. |
| 5074, 5079, 8079-002, 8093-002 | There are two potential failing items. Perform SIADPCD. If the problem persists after powering
on the frame or unit, then perform TWRPLNR. Attention: To prevent system VPD problems, do not replace both FRUs
at the same time.
|
| 5088, 0588 | There are two potential failing items. Perform SIADPCD. If the problem persists after powering
on the frame or unit, then perform TWRPLNR. Attention: To prevent system VPD problems, do not replace both FRUs
at the same time.
|
| 5094, 5294, 8094-002 | There are two potential failing items. Perform SIADPCD. If the problem persists after powering
on the frame or unit, then perform TWRPLNR. Attention: To prevent system VPD problems, do not replace both FRUs
at the same time.
|
| 5095, 0595, 7311-D20 | There are two potential failing items. Perform SIADPCD. If the problem persists after powering
on the frame or unit, then perform TWRPLNR. Attention: To prevent system VPD problems, do not replace both FRUs
at the same time.
|
| External xSeries server | Perform SIADPCD. |
| 7311-D10, 7311-D11, and 5790 | There are two potential failing items. Perform SIADPCD. If the problem persists after powering
on the frame or unit, then perform TWRPLNR. Attention: To prevent system VPD problems, do not replace both FRUs
at the same time.
|
| 5791, 5794, and 7040-61D | Perform TWRPLNR. |
This ends the procedure.