(2847) Reference codes

If the error is reported on the control panel, the unit reference code is characters 5 through 8 of the top 16 character line of function 11. If the error is reported on the console, the unit reference code is the 4 rightmost characters of word 1.

Find the unit reference code in the following table. For more on the Failing Item column entries, see Table 2. Failing items details, which follows the reference code table below.

Table 1. (2847) Reference codes

Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0A17 A permanent I/O processor failure occurred
0A22 I/O processor detected a storage transfer error
1307 I/O processor resource not available
1310 I/O processor resource not available

The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them.


3000 A permanent I/O processor failure occurred
3001 Not valid condition in I/O Processor Licensed Internal Code

The Licensed Internal Code found a condition that should not have occurred.

3002 Addressed device is not responding
3006 System bus error
3080 I/O processor Licensed Internal Code error
3081 System log entry only, no service action required

3084 I/O processor card or Licensed Internal Code error

A microprocessor exception occurred on the I/O processor.

3087 I/O processor resource not available

The Licensed Internal Code could not allocate resources on the I/O processor card.

3100 I/O processor card detected interface error
3109 I/O processor timed out a device command
3120 I/O processor detected a port failure
3200 A disk device reported a failure
3501 I/O processor Licensed Internal Code error
6070 A permanent I/O processor failure occurred
6071 I/O processor Licensed Internal Code error
6072 I/O processor Licensed Internal Code error
6075 I/O processor resource not available
6076 I/O processor card detected media error
6081 to 6083 I/O processor Licensed Internal Code error
6085 I/O processor Licensed Internal Code error
6200 A permanent IOA hardware error occurred
6201 IOA LID is not valid
8100 I/O processor Licensed Internal Code error
8150 A permanent I/O processor failure occurred
8155 to 8156 A permanent I/O processor failure occurred
8200 I/O processor Licensed Internal Code error
8300 I/O processor card or Licensed Internal Code error

A microprocessor exception occurred on the I/O processor.

8301 Not valid condition in I/O Processor Licensed Internal Code

The Licensed Internal Code found a condition that should not have occurred.

B3B1 to B3B7 A permanent I/O processor failure occurred
B3B8 Multi-adapter bridge error detected.
B3E0 to B3E1 I/O processor detected a fault condition.
B935 Unknown hardware detected
BE00 I/O processor detected a fault condition.

Table 2. Failing items details

Failing Item Description Document Description
AJDG301 Vertical Licensed Internal Code Service Functions; APAR or LICTR
AJDGP01 I/O processor Licensed Internal Code Service Functions; APAR or LICTR
AJDGP01 I/O card Licensed Internal Code Service Functions; APAR or LICTR
ANYBRDG System I/O bus or any attached card See the service documentation for instructions.
ANYBUS IOP card bus error See the service documentation for instructions.
ANYFC Any Fibre Channel device See the service documentation for instructions.
BACKPLN Card Enclosure or Planar Board See the service documentation for instructions.
CACHBAT Cache battery pack See the service documentation for instructions.
CACHE Cache adaptor card See the service documentation for instructions.
CMPRES1 Compressed device and compression IOA are not compatible See the service documentation for instructions.
CTLPNL Control panel, or the interface to the Control panel See the service documentation for instructions.
DEVBPLN Device backplane See the service documentation for instructions.
DEVTERM Terminating plug See the service documentation for instructions.
FCDEV Fibre Channel device See the service documentation for instructions.
FCINTF Fibre Channel interface See the service documentation for instructions.
FCIOA Fibre Channel IOA See the service documentation for instructions.
FCPORT Port not operational See the service documentation for instructions.
IOACNFG Configuration error See the service documentation for instructions.
IOP I/O processor card See the service documentation for instructions.
MA_BRDG Multi-adapter bridge See the service documentation for instructions.
MEDIA Defective media See the service documentation for instructions.
OPT_CLN Fiber optic cleaning kit See the service documentation for instructions.
PCIBUS Any PCI card on the PCI bus See the service documentation for instructions.
STORIOA Storage I/O adapter See the service documentation for instructions.
SVCDOCS Customer engineer directed to system problem analysis See the service documentation for instructions.
USER System Operator/User See the service documentation for instructions.