(B025) Reference codes

This SRC might indicate a communications error.

Find the unit reference code in the following table. For more on the Failing Item column entries, see Table 2. Failing items details, which follows the reference code table below.

Table 1. (B025) Reference codes

Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
A000 Input value error in I/O card Licensed Internal Code
A001 Input value error in I/O card Licensed Internal Code
A013 Wrong configuration data given to Ethernet controller
A01B, A209 Input value error in I/O card Licensed Internal Code
A404 Ethernet adapter card error
A6D5 to A6D6 Wrong configuration data given to Ethernet controller
A6D9 Ethernet adapter card error
A6E3 Ethernet adapter or network device cabling error.
A6F2 Configured line speed not supported by network.
A6F3 Configuration of DUPLEX parameter not supported by network.
A6F4 Unable to establish a network link.
A800 MAXFRAME value in CRTLINETH command too large.
CTPLPDU
A801 Adapter does not support user-configured adapter address
CTPNADR
B000 System log entry only, no service action required

B001 Automatic recovery has been attempted on the ethernet port

This error is logged for information only. No service action is required.


Table 2. Failing items details

Failing Item Description Document Description
AJDG301 Licensed Internal Code Service Functions; APAR or LICTR
AJDG301 Licensed Internal Code See the service documentation for instructions.
AJDGP01 I/O card Licensed Internal Code See the service documentation for instructions.
AJDGP01 I/O card Licensed Internal Code See the service documentation for instructions.
AJDGP01 I/O card Licensed Internal Code See the service documentation for instructions.
CTPLPDU MAXFRAME value in CRTLINETH command Communications Configuration
CTPNADR ADPTADR value in CRTLINETH command Communications Configuration
IOA Ethernet network adapter card Repair and Parts; removal and installation procedures
IOP I/O processor card See the service documentation for instructions.
UJE35 SSAP value in CRTLINETH command Communications Configuration
UJE35 MAXCTL value in CRTLINETH command Communications Configuration
UJE35 LINESPEED value in CRTLINETH command Communications Configuration
UJE35 DUPLEX value in CRTLINETH command Communications Configuration
UJE36 LANACKFRQ value in CRTCTL_____command Communications Configuration
UJE36 DSAP value in CRTCTL_____command Communications Configuration
UJE39 Remote computer equipment Communications Configuration
UJE40 Network Termination, Network or Network devices
USER User suspected communications problem.