Explanation

Two or more processors could not complete external time reference (ETR) synchronization check processing. ETR is the MVS™ generic name for the IBM® Sysplex Timer (9037) or equivalent.

System action

The system enters wait state X'0A4'. This wait state is accompanied by message IEA503W.

Operator response

Retain the logrec error records. Contact hardware support.

Source

Timer supervision