EZD1973E

z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
SC27-3655-01

EZD1973E
MULTIPLE tcpstackname NONRECOVERABLE ERRORS ARE ADVERSELY AFFECTING SYSPLEX PROCESSING

Explanation

Five TCP/IP abends occurred within one minute.

In the message text:
tcpstackname
The name of the TCP/IP stack.

System action

TCP/IP continues.
  • If the GLOBALCONFIG SYSPLEXMONITOR RECOVERY option is active and this stack is not the only member of its TCP/IP sysplex group, the following RECOVERY actions occur:
    • This stack leaves the TCP/IP sysplex group.
    • This stack no longer participates in sysplex distribution (as a distributor or target) or acts as an owner or a backup for DVIPAs. All DVIPAs defined on this stack are deactivated; however, the DVIPA definitions are saved.
    • When the stack leaves the TCP/IP sysplex group, this operator message is deleted.
  • If the GLOBALCONFIG SYSPLEXMONITOR NORECOVERY option is active, no action is taken.

See the information about sysplex problem detection and recovery in z/OS Communications Server: IP Configuration Guide for more information.

See the GLOBALCONFIG configuration statement in z/OS Communications Server: IP Configuration Reference for more information about the SYSPLEXMONITOR parameters.

Operator response

Save the documentation that was taken when the problem occurred and contact the system programmer.

If the NORECOVERY option is active, no further actions are needed.

If the RECOVERY option is active, then even if the GLOBALCONFIG SYSPLEXMONITOR AUTOREJOIN option is active, the stack will not automatically rejoin the TCP/IP sysplex group. Message EZZ9676E will be displayed if the TCP/IP stack successfully deactivates all DVIPAs and leaves the TCP/IP sysplex group. After message EZZ9676E is displayed, issue the VARY TCPIP,,SYSPLEX,JOINGROUP command to cause the DVIPA definitions to be processed and to cause the stack to rejoin the TCP/IP sysplex group.

System programmer response

Contact IBM® software support services with the TCP/IP profile, system log, and dump.

User response

Not applicable.

Problem determination

Not applicable.

Source

z/OS® Communications Server TCP/IP

Module

EZBXFPDC

Routing code

2,8

Descriptor code

2

Automation

Not applicable.

Example

MULTIPLE TCPCS NONRECOVERABLE ERRORS ARE ADVERSELY AFFECTING SYSPLEX PROCESSING