EZD1095I

z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
SC27-3655-01

EZD1095I
Unsupported configuration : location data endpoint dataaddr does not match security endpoint endptaddr for a transport mode Security Association initiated method

Explanation

The IP address for the data endpoint must be the same as the IP address for the security endpoint when using a transport mode Security Association (SA).

Additional diagnostic messages that have the same message instance number will be issued to identify the impacted SA. The message instance number precedes the message number in the log output and is used to group related messages from the IKE daemon.

location describes the data endpoint. The possible values are local and remote.

dataaddr is the data endpoint IP address.

endptaddr is the security endpoint IP address.

method describes how the SA was initiated. The possible values are locally and remotely.

System action

The SA negotiation fails; IKE daemon processing continues.

Operator response

If the data endpoint and security endpoint are different, use a tunnel mode SA; otherwise change the configuration so that the data endpoint and security endpoint addresses match. See the information about the Policy Agent and policy applications in z/OS Communications Server: IP Configuration Reference for more information about configuring policy.

System programmer response

None.

Module

policy.cpp

Procedure name

None.