On the Primary Task Selection panel, select Define,
modify, or view configuration data and on the resulting panel the object Switches. HCD displays the list of all switches currently
defined in the IODF.
Figure 73. Switch List (left part)
Goto Filter Backup Query Help
------------------------------------------------------------------------------
Switch List Row 1 of 6 More: >
Command ===> _______________________________________________ Scroll ===> PAGE
Select one or more switches, then press Enter. To add, use F11.
CU Dev
/ ID Type + Ad Serial-# + Description Num. Num.
_ 01 2032 21 10145 Switch 01 0701 0701 >
_ AA 9032 __ 10146 Switch AA 001A 001A >
_ AB 9032 __ 10147 Switch AB 001B 001B >
_ AC 9032 __ 10678 Switch AC 001C 001C
_ AD 9032 __ 10679 Switch AD 001D 001D
_ AE 9032-3 __ 20995 Switch AE 001E 001E
******************************* Bottom of data ********************************
F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F7=Back
F8=Forward F9=Swap F10=Actions F11=Add F12=Cancel F13=Inst
F20=Right F22=Command
The Switch List (left part), Figure 73, lists one switch
control unit and device. If there is more than one switch control unit and
device, the list entry gets an indication ('>'). With the F20=Right key,
you can scroll to the right part of the Switch List. Up to five switch control
units and devices can be shown. If there are more, an indication is given
for the corresponding entry ('Yes' in column 'More?' on the right part of
the Switch List). These additional switch control units and devices can be
viewed, for example, on the Port List for port FE.
Figure 74. Switch List (right part)
Goto Filter Backup Query Help
------------------------------------------------------------------------------
Switch List Row 1 of 6
Command ===> ____________________________________________ Scroll ===> PAGE <
Select one or more switches, then press Enter. To add, use F11.
CU Dev CU Dev CU Dev CU Dev CU Dev More?
/ ID Type + #1 #1 #2 #2 #3 #3 #4 #4 #5 #5
-------------------------------------------------------------------------------
_ 01 2032 0701 0701 0702 0702 0703 0703 0704 0704 0705 0705 Yes
_ AA 9032 001A 001A 002A 002A 003A 003A
_ AB 9032 001B 001B 002B 002B 003B 003B
_ AC 9032 001C 001C
_ AD 9032 001D 001D
_ AE 9032-3 001E 001E
******************************* Bottom of data *********************************
F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F7=Backward
F8=Forward F9=Swap F10=Actions F11=Add F12=Cancel F13=Instruct
F19=Left F22=Command
Use the F11=Add key to add a new switch.
Figure 75. Add Switch
*---------------------------- Add Switch ----------------------------*
| |
| |
| Specify or revise the following values. |
| |
| Switch ID . . . . . . . . 99 (00-FF) |
| Switch type . . . . . . . 9032 + |
| Serial number . . . . . . ASW3333333 |
| Description . . . . . . . First Switch____________________ |
| Switch address . . . . . __ (00-FF) for a FICON switch |
| |
| Specify the port range to be installed only if a larger range |
| than the minimum is desired. |
| |
| Installed port range . . C0 - FB + |
| |
| Specify either numbers of existing control unit and device, or |
| numbers for new control unit(s) and device(s) to be added. |
| |
| Switch CU number(s) . . . 0099 ____ ____ ____ ____ + |
| Switch device number(s) . 0099 ____ ____ ____ ____ |
| |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F9=Swap |
| F12=Cancel |
*--------------------------------------------------------------------*
HCD allows you to specify the port range of a switch to be set to installed,
if more ports are to be used than the minimum range. Specify the first and
last port of the range you want to use. If you do not specify values
for the Installed port range field, the hardware status of the minimum range
of supported ports is set to installed.
In order to allow
consistency checks for the configuration, when adding a new switch, you can
optionally define a switch address for a FICON switch.
You can also
specify control unit numbers and device numbers for the switch.
On
the Add Switch panel you can initially define up to five switch control units
and devices for the switch. To define more than five switch control units
and devices, or to add additional switch control units and devices later,
you must use the control unit and device definition dialogs.
If you
specify switch control units that do not yet exist, they are automatically
added as new objects to the IODF, and are connected to the switch through
the switch control unit port. In this case, you need to specify new switch
devices. The switch devices are also automatically added as new objects to
the IODF and connected to the switch through the switch control units. However,
to complete the configuration path, you must attach the switch control units
and switch devices to a processor, and then you can assign the switch devices
to an operating system.
If the switch control units already exist,
they are automatically connected to the control unit port on the newly defined
switch. In this case, you do not need to specify switch devices. If you
do, the switch devices must already exist and be attached to the designated
switch control units.
Specified serial numbers or descriptions are
also copied to the switch control units and switch device definitions.