Previous topic |
Next topic |
Contents |
Index |
Contact z/OS |
Library |
PDF
Activate a configuration HMC-wide z/OS HCD User's Guide SC34-2669-00 |
|
Activate a configuration HMC-wideHCD provides a function to manage dynamic I/O changes from a single point of control (managing system) for all systems running on CPCs that are controlled by the same hardware management console (HMC). The function includes the following features:
To work with HMC-wide activate functions, start from the System z Cluster List (Figure 93), where you can select action Work with CPC images (action code v ) to obtain the CPC Image List (see Figure 104). The CPC Image List displays information about the selected CPC. This includes the processor ID, SNA address, and the HSA token. Partitions that are deactivated or not IPLed, or that do not run any z/OS (MVS) or z/VM (VM) system are shown as disabled (with a #sign in the action column) and no action is possible for such a partition. Also all LPARs without an entry in the connection table which are not reachable indirectly via a reachable sysplex are listed but marked as disabled (#) in the action column. The CPC Image List displays all partitions defined on the selected CPC with their operation status, connection status, and activation status:
Figure 104. CPC Image List
Goto Query Help ------------------------------------------------------------------------------ CPC Image List Row 1 of 60 More: > Command ===> _______________________________________________ Scroll ===> PAGE Select one or more systems of the CPC, then press Enter. To refresh the Activate/Verify Status, press Enter without selections made. Processor ID : R35 SNA Address : IBM390PS.R35 HSA Token . : R35 12-02-06 09:26:03 SYS4 IODF71 -- Partition --- Co Sysplex ------- System ------- ----- Activation ----- / Name ID Stat St Name Name Type Level HW SW Status _ DWB1 2A 0001 DWB1PLEX DWB1 MVS 1.12 _ DWB2 3A 0001 DWB1PLEX DWB2 MVS 1.12 _ IRD6 1B 0001 Y IRD4PLEX IRD6 MVS 2.1 Y Y _ R35LP29 1E 0001 R35SSI BOER3529 VM 6.2 _ R35LP43 2D 0001 R35SSI BOER3543 VM 6.2 _ TRX1 2C 0001 S TRX1PLEX TRX1 MVS 2.1 Y Y _ TRX2 3C 0001 Y TRX1PLEX TRX2 MVS 1.13 Y Y # IRD7 0C 0002 # IRD8 1C 0002 N # R35LP10 0A 0001 LINUX 3.0.13 F1=Help F2=Split F3=Exit F7=Backward F8=Forward F9=Swap F10=Actions F12=Cancel F13=Instruct F14=SortName F15=SortStat F16=SortSplx F22=Command Scrolling to the right displays further activation status information as shown in Figure 105:
Figure 105. CPC Image List scrolled to the right
Goto Query Help ------------------------------------------------------------------------------ CPC Image List Row 1 of 60 More: < Command ===> _______________________________________________ Scroll ===> PAGE Select one or more systems of the CPC, then press Enter. To refresh the Activate/Verify Status, press Enter without selections made. Processor ID : R35 SNA Address : IBM390PS.R35 HSA Token . : R35 12-02-06 09:26:03 SYS4 IODF71 Partition Active Conf EDT / Name IODF ID ID _ DWB1 _ DWB2 _ IRD6 SYS4.IODF10 MVSVM 00 _ R35LP29 _ R35LP43 _ TRX1 SYS1.IODF01 MVSVM 00 _ TRX2 SYS1.IODF01 MVSVM 00 # IRD7 # IRD8 # R35LP10 F1=Help F2=Split F3=Exit F7=Backward F8=Forward F9=Swap F10=Actions F12=Cancel F13=Instruct F14=SortName F15=SortStat F16=SortSplx F22=Command Use PF keys to sort the list by the following columns:
From the CPC Image List you can launch dynamic hardware and software configuration changes on any reachable system (in any sysplex) on any CPC that is configured in the same Hardware Management Console (HMC). All available actions are introduced in Available configuration activation actions. Press the Enter key without further selection to refresh the display of the activation status, for example, when there is an activation in progress. The save list function is available for the CPC Image List. Note:
If you stopped and restarted an HCD dispatcher on a
connected system, while you have opened a CPC
Image List connected to the CPC where this system is running,
you must reconnect this CPC before performing any new action on the CPC Image List containing the concerned system.
Otherwise you may get message CBDA605I, saying that HCD remote
processing failed. |
Copyright IBM Corporation 1990, 2014
|