Inspecting the installation log |
Read the ant.log file. This file contains information about that steps that were
taken during the installation. The file is written to the IBM TRIRIGA root installation directory. For example, on Windows, C:\Tririga\ant.log is the typical location.
A line toward the end of the file indicates whether the installation
succeeded or failed, such as the following examples: - The installation succeeded:
BUILD SUCCESSFUL
Total time: 25 minutes 51 seconds
- The installation failed:
BUILD FAILED
C:\Tririga\build.xml:2586: The following error
occurred while executing this line:
C:\Tririga\build.xml:2141: Java returned: -1
Total time: 8 minutes 44 seconds
|
Starting the application |
Start IBM TRIRIGA by locating the application server directory with the appropriate
method.
|
Accessing the application |
Verify your access to the IBM TRIRIGA application as the system user as follows: - Specify the URL address in your browser address field. The URL
looks something like http://[hostname:port][/context_path], where [hostname:port] and [/context_path] are
the specific values for your environment. If you see the error message
"Unable to launch the application", then you must set the FRONT_END_SERVER property.
- Sign in with your user name and password. The default user name
is "system" and the default password is "admin".
|
Accessing the administrator console |
Verify your access to the IBM TRIRIGA administrator console as follows. - Specify the URL address in your browser address field. The URL
looks something like http://[hostname:port][/context_path]/html/en/default/admin, where [hostname:port] and [/context_path] are the specific values for your environment.
- Sign in with your user name and password. The default user name
is "system" and the default password is "admin".
- In the Agent Manager, start the following agents in the process
server: Platform Maintenance Scheduler Agent, Extended Formula Agent,
Formula Recalc Agent, Scheduler Agent, Workflow (WF) Agent, and Workflow
(WF) Notification Agent.
- Sign out of the administrator console.
|
Creating users and records |
As the system user, create and verify
an IBM TRIRIGA employee who is not an administrator as follows: - Assign the user to several user groups, but not all of them.
- Assign the user with several user licenses, but not all of them.
- Sign in as the user that you created.
- Verify that the user can access everything that the employee is
meant to access, according to the assigned groups and licenses.
- Verify that the user can create and revise records, such as people
records and location records.
- Verify that the association tree loads in the Associations tab of an opened record.
|
Using the builder tools |
As the system user, open and verify
the builder tools under as follows: - In the workflow builder, verify that workflows load completely
by opening and revising existing workflows.
- In the data modeler, verify that the state transitions load completely.
- In the data modeler, verify that the simple mail transfer protocol
(SMTP) email notification works by publishing a test business object.
|
Using the Document Manager |
As either the system user or a user
with rights, open and verify the Document Manager under as follows: - Verify that the user can upload new documents, such as .txt, .html, and .jpg files.
- Verify that the user can upload new documents with the multifile
applet.
- Verify that the user can view documents by clicking the icon in
the V column.
- Verify that the user can check in and check out documents.
- If Brava is installed, verify that the user can upload computer-aided
design (CAD) documents in .dxf format and view
the CAD documents by clicking the icon in the V column.
|
Editing project tasks |
As either the system user or a user
with rights, verify the functions as
follows: - Create or open a new capital project.
- In the Schedule tab, add or open a task
in the Project Tasks section.
- In the task, edit the planned start date, planned end date, or
planned working hours.
- Verify that when one field is edited, the other two fields are
adjusted automatically.
|
Syncing CAD drawings |
If IBM
TRIRIGA CAD Integrator/Publisher is being used, verify your access to IBM TRIRIGA as follows: - Start TRIRIGA CAD Integrator/Publisher.
- Sign in as a user with a TRIRIGA CAD Integrator/Publisher license.
- Verify that the user can sync a CAD drawing with TRIRIGA CAD Integrator/Publisher.
|
Inspecting the server log |
Verify that the server.log file exists for each application server and process server. This
file is written to the log directory of the IBM TRIRIGA installation. For example, on Windows, C:\Tririga\log\server.log is the typical location.
In addition: - Verify that the application server is writing to its server.log file. Inspect the file for any major exceptions
on first startup.
- Verify that the process server is writing to its server.log file. One day after the installation and on a regular basis, verify
that the process server completed the cleanup process successfully.
|