IBM Support

Fix list for Rational Tau

Product Documentation


Abstract

This document contains a complete listing of releases, refreshes, fix packs and interim fixes sorted by version for IBM Rational Tau.

Content

Tab navigation

IBM Rational Software Support Communities
  • Visit the IBM Support Portal to configure your support portal experience and review FAQs, lists of known problems, fixes, and a wealth of important support information.
  • Visit developerWorks to access an online collection of tutorials, sample code, standards, forums and other resources provided by experts at IBM to assist software developers using Rational tools including access to the IBM RFE Community.
  • Visit the Jazz Community if you use a Rational product created using the Jazz platform to interact directly with the Jazz development team and other community members, download product trials and betas and track development progress.

Helpful Hints For Obtaining Technical Assistance:

Before you contact IBM Rational Software Support, gather the background information that you need to describe the problem. When you describe a problem to an IBM software support specialist, be as specific as possible and include all relevant background information so that the specialist can help you solve the problem efficiently. To save time, know the answers to these questions:

  • What software versions were you running when the problem occurred?
  • Do you have logs, traces, or messages that are related to the problem?
  • Can you reproduce the problem? If so, what steps do you take to reproduce it?
  • Is there a workaround for the problem? If so, be prepared to describe the workaround.

If you have helpful information to diagnose or identify the problem on your system, you can provide this data by following the instructions to exchange information with IBM Technical Support.

Table of Contents:


Interim Fix 1 (4.3.0.6_iFix001)
Link Date Released Status
APAR Description
-- Released to resolve security vulnerability in OpenSSL. Review 1676786: Security Bulletin: Rational Tau is affected by OpenSSL vulnerabilities (CVE-2014-0224) for details.

Fix Pack 6 (4.3.0.6)
Link Date Released Status
APAR Call Ticket CR ID Synopsis Release Notes Text
PK99170 03195,999,706 TLOG#54368 Not possible to import the math.h file from version 9.0 of Microsoft Visual Studio It was not possible to import the C++ math.h file and other files from version 9.0 of Microsoft Visual Studio (2008). C++ Importer has been updated to parse these header files correctly.
67792,019,866 TLOG#73060 Please extend the functionality of XTNOUSE Functionality of XTNOUSE_ptr_ has been extended. Now #ifndef XTNOUSE_ptr_ is also added around operators and initialize functions for ptr_ type.

Fix Pack 5 (4.3.0.5)
Link Date Released Status
Call Ticket CR ID Synopsis Release Notes Text
21093,019,866 TLOG#67502 Using 'unsigned' char creates test values that can crash the Validator when removed We have changed how unsigned char is read and written. It is now written as hex literals: 0x00 - 0xff. It can read hex or decimal values.
21094,019,866 TLOG#67503 Specific model gives no trace in the Validator Some models gave a SYNTAX ERROR when trying to open Validator trace on a Sequence diagram and the trace was missing instances. This problem has been fixed.
38136,019,866 TLOG#69053 TSC0153 warning faulty issued in certain situations (Please check Hanging_v2.zip.) TSC0153 warning was faulty issued in certain situations. This problem has been fixed.
54330,999,760 TLOG#69347 Tau 4.3 Semilocon is lost during code generation When statements inside the task symbol end with a labelled empty statement ( LAB:; ) last semicolon is lost during code generation and it results in syntax errors: TIL2312: Syntax error in rule STMT This problem has been fixed.
68987,999,760 TLOG#69386 Tau 4303 crashes when Model Verifier starts up Tau crashed after C code generation when loading a huge GenerationResult.u2 file. This problem has been fixed.
91187,663,706 TLOG#69497 Not possible to Browse a database with any other that exactly 14 character long name The problem was in GetPathFromDisplayedName method which removes first 14 characters from path not given that name length could be different. The fix was in reimplemeting this method to remove database name from given path.
71608,999,760 TLOG#69625 Link can not be deleted After creating a link from initialize() of StateMachineImplementation in State machine to initialize() itself, the link (StateMachineImplementation of initialize()) can not be deleted. This has now been fixed in 4.3.0.5
69545,999,760 TLOG#69626 Error on replacing octet variables Sending a signal with Octet value containing digits (for example, '01'H) in Model Verifier resulted in "Error 45" Error when decoding octet from buffer. This problem has been fixed.
72028,999,760 TLOG#69758 Instance generation order is incorrect Object initialization order for nested objects is modified by the new "Initialize container object prior to its parts and keep the order of objects" checkbox. By default we initialize container object after we have initialized its parts, but with this option enabled the object hierarchy is initialized from top to bottom.
70170,999,760 TLOG#69786 Informal expressions should not be treated as Boolean Else-branch of a decision symbol leads to an "error" state when decision value is {{ informal statement }} and there is more then one answer branch in that decision. This problem has been fixed.
72028,999,760 TLOG#70069 xPartData_objSGC_SV_4S generated before TLM series Instance creation order for AgileC code generation is same as the order of their definitions when the "Initialize container object prior to its parts and keep the order of objects" check-box is enabled.
90911,999,760 TLOG#71603 Model verifier stop button increase memory usage Modifications are made to minimize memory fragmentation in Model Verifier.

Fix Pack 4 (4.3.0.4)
Link Date Released Status
Call Ticket CR ID Synopsis Release Notes Text
82578,019,866 TLOG#57622 Please add a call to GenericDefault in sctpred.c GenericFreeSort now sets the Length field to 0 after freeing types based on Bit_String and Generic_String.
82578,019,866 TLOG#57623 Please introduce a NULL-pointer check for BlockProcess Introduced a NULL-pointer check for BlockProcess.
55478,122,000 TLOG#63948 Unsigned integer division is incorrect in MV Unsigned integer div("/") and rem operations could give an incorrect result for big unsigned values. This problem has been fixed.
58787,122,000 TLOG#64444 No matching infix operator in Tau 4.3.0.3 Corrected C code generation to correctly handle attributes of type 'char*' with default value.
15847,019,866 TLOG#65564 Tau code generation is not reproducible The transformation which generates 'itself' parameter was be applied first as it should. This has now been fixed.
46222,122,000 TLOG#68237 Conversion from large unsigned to signed with overflow will occur for xMod_SDL_Integer Unsigned integer mod("%") and fix operations could give an incorrect result for big unsigned values. This problem has been fixed.

Fix Pack 3 (4.3.0.3)
Link Date Released Status
APAR Call Ticket CR ID Synopsis Release Notes Text
PK81224 03396,122,000 TLOG#48882 Tau code generation errors related to GUID- TIL2369,TIL2341 Previously when generating C code for a model errors related to none visible definition from other package could show up ( TIL2077: Undefined sort, TIL2369: No matching field selection, TIL2371: Type mismatch... ). These errors related to the handling of syntypes for passive classes and to the mechanism for initializing attributes in generated code. Code generation has now been improved to avoid these errors.
  51689,000,744 TLOG#52246 Want Natural to be mapped to ‘unsigned int’ The mapping for Natural has been changed to 'unsigned int' in generated code.
  91613,100,838 TLOG#55212 Please intoduce a 'Yes to all' button for DOORS modules when saving Tau model Now modules saves before closing.
  93052,100,838 TLOG#56861 DXL error when using 'DOORS - locate' and the DOORS module do not exist A null pointer check was added to the locate function.
  81349,999,744 TLOG#58171 Brackets are missing error reported on build after the file was re-imported The case is duplicate of TLOG#57970
  67219,122,000 TLOG#60043 TIL2312 error observed during build for statements with mod (%) operator. Added support for % operator.
  86296,122,000 TLOG#60883 HTML Report Generation causes Tau crash Memory leaks on image saving have been removed.
  87429,019,866 TLOG#60885 One can not define XCONST for SCTAPPLCLENV XCONST and XCONST_COMP macros are obsolete and we have updated the documentation accordingly
  89657,019,866 TLOG#61154 XPRINTALLOC prints faulty memory usage when using external functions XPRINTALLOC mode has been fixed to print current memory usage with regard to xFree calls. It decreases total allocated memory size if memory is freed. Documentation on XPRINTALLOC and XCHECKALLOC compile switches has been added.
  86422,019,866 TLOG#62218 Optimization wanted in the Dynamic Range Checking The flags XECUSTOMHANDLERS and XENOUSERWF have been added to the kernel. They allow the user to remove the need for the coder functionality when using error checking functions and to supply their own implementations for error handling.
  92474,019,866 TLOG#62224 Further differences in the generated code Redesigned C code generator to avoid random names and random order of elements in the generated C code.
  94287,019,866 TLOG#62934 Class hierarchy unnecessary initialized multiple times Fixed problem with multiple initialization of struct fields.
  94234,019,866 TLOG#62937 Call to an inherited function do not work as expected Added Model Verifier/C code generation specific check for virtual/redefined operations in passive classes and datatypes.
  94551,019,866 TLOG#63088 Tau crashes during Compare/Merge The crash occured while comparing/merging two models when differences between these models included "move" operation of an expression action specified on text diagram. This problem is fixed now.
   92474,019,866  TLOG#62224  Further differences in the generated code  Redesigned C code generator to avoid random names and random order of elements in the generated C code.
   94551,019,866  TLOG#63088  Tau crashes during Compare/Merge The crash occurred while comparing/merging two models when differences between these models included "move" operation of an expression action specified on text diagram. This problem is fixed now.
PM22590  92474,019,866  TLOG#62224  Further differences in the generated code  Redesigned C code generator to avoid random names and random order of elements in the generated C code.
  48366,122,000 TLOG#57972 Error TIL2066 observed when using an attribute. Having const attributes in passive classes from different packages resulted in TIL2066 error when using one of attributes in scope where the class owning the other one was also visible. This problem has been fixed.
  88151,122,000 TLOG#60928 Tau models with external operations returning OctetString crashes during sdtsan C Code generator crashed when an external function without parameters with only return value was used in expression for which procedure result is passed by reference (for example, assignment expression for OctetString str = MyFunc();). This problem has been fixed. There is also a workaround for the issue - add one dummy parameter to external function.
    TLOG#61366 variables not initialized if a class doesn’t have a state machine associated with it - Now variables will be initialized  
  89618,019,866 TLOG#61130 Differences in cast operators between code generated on different machines Changed the algorithm for generation @cast_XXX operators. Now it will use fixed suffixes for operator names. This should keep generated code the same on different platforms/machines.

Fix Pack 2 (4.3.0.2)
Link Date Released Status
APAR Call Ticket CR ID Synopsis Release Notes Text
  7021731 TLOG#37323 Option to edit merge result in review differences dialog. The "Editable Merge" feature are implemented in the Tau Compare/Merge tool. This feature allows to edit merge result directly in the review difference dialog.
  3042861 TLOG#46463 Tau 4.2 crashes only on Chiness XP when running specific model Problems with multibyte encodings sometimes caused crash on Chinese and Japanese machines and sometimes resulted in incorrect symbols on MSC diagram during verification. These problems have been fixed.
  3043809 TLOG#47448 Step Over did not step over the operation Added documentation on how to properly step over RPC calls in Model Verifier.
  7033524 TLOG#47884 Faulty TestCase translation when signals can be both sent and received by SUT Signal output to SUT is not correctly translated when the same signal is both sent to and received from SUT. This results in FAIL verdict for the test that works ok. This defect has been fixed.
    TAU#8214 Implement Compare/Merge support for Analyst models. New menu to the CM module was added for support projects and model selection form Doors DBs.
  51165,000,744 TLOG#51359 An option to obtain the coverage statistics through console window. Print-Coverage-Table console command has been extended to obtain coverage statistics from command line. A new section with coverage statistics is now printed into the specified file for Print-Coverage-Table command. It looks like this: ****************** COVERAGE STATISTICS *********************   Active class name : unit kind : Covered% ( N Covered / N Defined ) ---------------------------------------------------------------------------- TOTAL : Statements : 60% ( 34 / 56 ) TOTAL : Transitions : 62% ( 10 / 16 ) ---------------------------------------------------------------------------- Controller : Statements : 54% ( 23 / 42 ) Controller : Transitions : 54% ( 6 / 11 ) Hardware : Statements : 78% ( 11 / 14 ) Hardware : Transitions : 80% ( 4 / 5 )   The following requirements are achieved: 1) Same Transitions, Symbols covered in consecutive runs do not increment counts. "N Covered" shows overall count which holds the different transitions, symbols covered in consecutive runs   2) Report contains the total number of transitions, symbols defined in the model, and the total coverage percent   3) It is possible to get statistics in the very beginning of model execution, when no symbols and statements have been covered. The table will contain 0 for coverage, but correct figures for the total number of defined transitions and symbols
  51132,000,744 TLOG#51360 An option to obtain the coverage statistics with total number of transitions covered under multiple test cases. Print-Coverage-Table console command has been extended to print coverage statistics for transitions and symbols that contains : 1. Total No. Transitions, symbols defined in the model. 2. Total No. of Transitions, symbols covered in the test executions (in a single launch session) such that a transition / symbol counted during a particular test execution is not counted again if covered as a part of the sub-sequent test execution(s).   Coverage statistics is printed into into new section "*** COVERAGE STATISTICS ***".
  70337,019,866 TLOG#51621 Please make it possible to sort the signals in the MV signal list drop-down box New option is introduced to make entities in combo boxes of MV Messages view sorted alphabetically. This option is available in Advanced options tab, via U2/Debugging/SortedComboBoxes path. Option is on by default.
  64766,019,866 TLOG#51746 Building a model that initially was saved at urn:u2tauproject gives a lot of errors and warnings if it has been moved Tau will prefer relative paths over absolute when saving model parts in different files.
  00404,999,706 TLOG#52557 Breakpoint is missed during test case execution due to a signal receipt failure on Test Profile artifact. Now if state has just one triggered transition with guard condition for the same signal, the arguments of the signal will not be ignored when generating C code. For the case when state has more than one such transition, a proper warnings will be generated during the build.
PK95079 71517,999,744 TLOG#52966 Tau Testing Profile build aborts with message 'Test Generation Failed' with no actual errors but the error count Tau Testing Profile build aborts with message 'Test Generation Failed' with no actual errors but the error count. This happens when the model contains <> elements, for example, interaction diagrams that reference private class attributes. Error messages are not printed to output tab, because they refer to informal elements, but error messages are visible if you run Build from command line using TauBatch. This problem has been fixed. Informal elements are now ignored during check.
PK98783 64579,019,866 TLOG#54268 Performance problems in a big model This is now mentioned in the Known Limitations document.
PM00003 01792,SGC,618 TLOG#54535 Comments are not synched to Tau (DOORS stored model) when changed in DOORS The documentation is updated.
  05341,122,000 TLOG#54615 TIL2087 reported in a scenario although PID expression is not used. Fixed translation of the call expression where the called operation has the same name as operation that contains the call expression.
    TAU#8721 Containment line can be started on symbols that can't be containers Now only StrucutureClassifier, Package, DataType, Method and Collaboration can be source of ContainmentLine.
  53020,000,744 TLOG#54882 OPERATION DECLARED PUBLIC IS NOT EXECUTED BY TAU. Now the local calls of remote operation are not translated as remote calls.
PM01409 15961,122,000 TLOG#54995 Not able to get back to the Automated merge result (duplicate of verified CR: TOG#24041) Remerge now works correctly for text text symbols and task symbols.
  91613,100,838 TLOG#55212 Please intoduce a 'Yes to all' button for DOORS modules when saving Tau model Now modules saves before closing.
PM02757 46250,650,758 TLOG#55329 OBJECT (NAMEDINSTANCE) SLOT NOT CONSISTENT BETWEEN DIAGRAM/MODELVIEW/PROPERTIES Previously when slot expressions were created in property editor they did not appear in model view. It has been fixed.
  30830,999,000 TLOG#55470 THE TAU-SYNERGY INTEGRATION DO NOT ALLOW YOU TO GIVE YOUR CREDENTIALS WHEN LOGIN INTO SYNERGY FROM A LINUX MACHINE The username and password credenials input filelds was added.
  80316,999,744 TAU#8926 Issue with the initialization of variables of type Enumerations and Booleans in derived classes. Corrected translation of default values of class attributes.
    TAU#8842 Import SDL for Japanese OS - failed The Known Limitations document have been updated.
  93052,100,838 TLOG#56861 DXL error when using 'DOORS - locate' and the DOORS module do not exist A null pointer check was added to the locate function.
  29918,122,000 TLOG#57349 Cursor moves to the left when a message name is typed (duplicate of TLOG#56762 and TLOG#56898) Previously cursor could jump to the left when editing text in certain situations. It has been fixed.
  82578,019,866 TLOG#57621 Please introduce a NULL-pointer check for xHexStr_SDL_Octet Fixed a bug in xHexStr_SDL_Octet that allowed bad input.
  82591,019,866 TLOG#57627 Please document the SCTDEBRMT compiler flag Added documentation for the SCTDEBRMT compiler flag
  82591,019,866 TLOG#57738 Using the 'conditional' Stereotype causes build to fail with TSC4515 Added checks to ensure that only readonly attributes with default value are used in <> stereotype.
  82905,019,866 TLOG#57818 Test Profile does not take the conditionalInit() operation into consideration Test Profile now takes into account conditionalInit() operation.
  91632,999,000 TLOG#57820 TCI0007 error encountered when trying to import a C++ file into Tau. Import of Borland C++ code has been improved.
  83389,019,866 TLOG#57920 Faulty help files regarding Conditional Constants Documentation updated.
  53719,000,744 TLOG#57943 TIL ERRORS WHILE BUILDING A MODEL Now syntypes of passive classes are properly handled by C/Model Verifier code generator.
  83012,019,866 TLOG#58172 Using a 'const' as in/out parameter is not found by checker. Give TIL-error Usage of constant as actual argument for in/out or out parameter is now checked by the semantic checker.
  10287,999,000 TLOG#59111 Incorrect WSDL generation by Tau with the Generate WSDL option Corrected generation of WSDL from pure UML models.
  86076,019,866 TLOG#59357 Tau Kernel files contains dubious comments Obsolete dubious comments and commented code were present in some installation kernel files. They have been removed or rewritten to reflect up-to-date status.
  67194,122,000 TLOG#59622 Tau 4.3.0.1 generated binary crashes with error :"glibc detected *** : double free or corruption (fasttop):" Tau crashes with an error:"glibc detected ***: double free or corruption (fasttop):" when executed on target machine. It happens when the model calls external C function that creates a new charstring with 'T' as first symbol, which means temporary value (should not be copied with strcpy but can be reused during expression evaluation and assignments). This problem has been fixed.
  88060,019,866 TLOG#60469 Sending in an OctetString to an external function causes a memory leak Passing OctetString type as a parameter to an external function caused memory leak and forced to call free inside external function that was not needed before. This problem has been fixed.

Fix Pack 1 (4.3.0.1)
Link Date Released Status
APAR Call Ticket CR ID Synopsis Release Notes Text
  6004951 TLOG#21140 Using Accept/Reject buttons make no difference in the Result View It was not possible to select a proper merge result for a text in InlineFrameSymbol by selecting Version1/Version2/Ancestor in the ReviewDifference dialog. This problem is fixed now.
PK96460 6005942 TLOG#21832 Error in signal routing In previous versions of Tau the C/Model Simulator code generation produced wrong code for models containing an active class with an internal structure. Implicit connectors were generated for non-behavior ports that had explicit connectors. This caused wrong execution of the generated code. Now generation of implicit connectors has been fixed to avoid creation of unnecessary connectors.
  1050953 TLOG#24780 Shouldn't be possible to send/receive signals to private(behaviour)port of class Now the semantic checker reports a warning if a connector is connected to a private behaviour port.
  3038367 TLOG#39297 Issue when Timer Optimization is Enabled Fixed AVL timer queue handling problems which resulted in wrong behaviour of the generated code when Timer Optimization is Enabled. Updated functions SDL_Reset and SDL_Stop from sctsdl.c .
  2084234 TLOG#39430 Tau 4.0 Eclipse integration regression The menu with location and synchronization items for editor window was reimplemented.
PK84718 and PK88493 2084875 TLOG#39983 getpidbl returns wrong process instance For a part containing statemachine with finite multiplicity > 1 that composes another part, sending signals to instance #2, #3 etc. does not work fine and signals in any case are received by instance #1. This has now been fixed. There are three new semantic checks implemented. A class attribute check fires only when a parent class attribute is used in the other scope and the parent class (or its derived or base classes) contains parts or nested active classes and there is somewhere a non single attribute of this type.
  1060683 TLOG#40100 Multiplicity of Active Class behavior and with internal structure is unsupported Clarified documentation about the C code generator limitation that multiplicity of active classes with behavior and with internal structure is not supported.
  4052832 TLOG#42575 Association multiplicity not shown on diagram unless file is checked out Association line multiplicity was not displayed for lines that were in a non-editable state (such a checked in element under source control).
  7028019 TLOG#42598 Please indicate the (Synergy) model version/release that is loaded in the tool Now synergy information indicates by following manner: Template: {}} Example: Package1.u2 {my_rel-1.2.1} In Doors Integration Version before {...} adss 'scc': 'scc{}'
  7028063 TLOG#42767 TauG2 4.1 does not explain why "No licenses available" For the first checkout call in a session and a license server is used a check is made to make sure that the license server FLEXnet version is equal or higher than the application API FLEXnet version. The return value is TL_WRONGSERVERVERSION if there is mismatch of versions. Thus the call to tl_CheckServerVersion is not needed. For details on the functionality see the tl_CheckServerVersion function. The idea is that you can override this error by trying again.
PK84713 7033775 TLOG#48178 Tau 4.2.0.1 Simulator not running correctly a Tau 3.1 model Added backward support for old debug configuration files.
  2092933 TLOG#48180 Tau Validator - test value - removing one singal removes all Tau Model Explorer: In the Test Values tab, it is now possible to remove a single signal by clicking the '{Remove}' link next to it. Previously this resulted in all signals of the same type being removed. The functionality is also available for the command line interface by using the new command "Clear-Single-Signal".
PK81224 3044682 TLOG#48882 Tau code generation errors related to GUID- TIL2369,TIL2341 Previously when generating C code for a model the error TIL2371: Type mismatch... could show up. This error related to the mechanism for initializing attributes in generated code. The initialization mechanism has now been improved to avoid this error.
PK81516 92467,180,000 TLOG#49016 VCS.EXE - catastrophic memory growth for each transition fired New option to switch the execution history saving was added. This enables user to get rid of history if he does large calculations.
PK81820 73293,487,000 TLOG#49180 Cannot associate Tau project to Synergy Task Now while creating new project it is possible to select existing user task and use it or create new one like it was possible in previous versions. Also in this case was fixed bug with user tasks list in toolbar. It has no tasks while start up. Now it's fixed.
PK82581 53369,100,838 TLOG#49473 Error importing Java code Now there is no errors appear. All changes were done in compliance with recommendations.
PK84712 90953,999,706 TLOG#49868 TNR errors while trying to build the model Corrected translation of triggered transitions with the same trigger, but different guard transitions.
PK86568 92300,999,706 TLOG#50962 Import if several xsd files containing includes duplicates the imported schemas When importing multiple XSD files including other schemas, each schema is now only imported once, even if it is included several times.
PK87224 50901,000,744 TLOG#51090 Multiple composite states when used in a state symbol seperated by comma do not work. Added semantic error for the case when state symbol has reference to more than one composite state.
PK89594 93914,999,706 TLOG#51667 Signals from packages with é in the name get scrambled parameters in the SQD trace A problem related to corrupted text strings in the sequence diagram trace produced by the Model Verifier has been solved.
PK92156 48241,122,000 TLOG#51852 XML read errors while trying to diff merge a Tau U2 file from Clear Case. When trying to do diff merge a .u2 file from within Clear Case user would get an error. This has not been fixed by load the single .u2 file into Tau (as an incomplete model). There is a risk in doing this that the model will now become corrupt. Please see Help for more information.
PK90706 94489,999,706 TLOG#51965 <> stereotype causes Syntax errors when later edited Textual syntax is fixed to allow stereotypes for timers and signals in class symbol.
PK90741 94541,999,706 TLOG#51973 Model Browser still export diagrams that has the <> stereotype applied Now <> diagrams are not exported to HTML
PK92253 77815.100.838 TLOG#52332 DOORS Analyst 4.3 opens with a blank page. When a project stored in DOORS was loaded for the first time and Tau was closed without saving the workspace, the project would not be properly loaded the next time. This has now been fixed.
PK92850 00378,999,706 TLOG#52453 Tau model with signal receipt and guard after a '*' state,reports NMAKE errors during make. Generated C code may result in "'x' : is not a member of 'T'" compile errors when: 1) An active class B inherits from active class A 2) Active class B contains a triggered transition from state * with a signal and a guard condition that references class B local variable (for example, Signal1(a) {a == b}, where 'a' and 'b' are class B local variables)   This problem has been fixed.
PK93249 48571,663,706 TLOG#52571 DOORS Analyst tries to save and synchronize even if there are no changes made. Force saving workspace after loading project was added to avoid wrong workspace creation and saving.
PK93724 78065,100,838 TLOG#52686 TM Errors when trying to convert a module Model files referenced by model dependencies are now only loaded when creating a new project or when inserting a file into an existing project. To resolve missing files in other situations, the files needs to be inserted into the project manually.
PK94118 01601,SGC,821 TLOG#52789 Dependency between namedinstances in Object Diagram does not bind and shows up in red Now dependency can be bound to named instance.
PK95824 78847,100,838 TLOG#53214 TAU crash - APAR: PK95824 Corrected infinite recursion in the name resolution.
  50858,999,000 TLOG#53274 Connector lines cannot be printed in color. Lines were previously always printed black, even though the line was colored.
PK96140 85868,122,000 TLOG#53317 A Syntype definition from the U2p file is not updated on to the U2 file. Now "constants" constraint is updated correctly from u2p file.
PK98966 05010,122,000 TLOG#54312 A commented assignment line when uncommented leads to TNR0029 error during build Certain edit operations such as copy/paste in state chart diagrams, or certain editing operations in a text symbol, could occasionally lead to a model corruption (duplicate GUIDs). This problem has now been resolved.
PM00185 73664,999,744 TLOG#54608 TSC0283 error seen when customer builds the model on Tau 4.3 Template transformation has been corrected to avoid occasional expansion of predefined C/C++ templates like CPtr, CArray, etc.
PM00180 07995,122,000 TLOG#54616 Tau 4.3.0.0 version crashes during compare / merge. The Compare/Merge tool crashed because of the bind issue in parallel versions of a model (Version2/Ancestor) This bind issue is fixed.
PM00270 90773,100,838 TLOG#54632 Rational DOORS Analyst ask about saving when closing directly after a Save All Unnecessary Save requests have been removed.
PM00361 90810,100,838 TLOG#54657 UML-objects not saved at correct location in Tau UML elements created in DOORS were in some situations created at an incorrect location when committing the changes to Tau. This has now been fixed.
  79484,100,838 TLOG#54660 Please increase the COM-timeout for Tau-DOORS Synchronization It is now possible to control the behavior of the COM timeout mechanism used when communicating with DOORS by using two registry values. Two keys are defined in HKEY_LOCAL_MACHINE\SOFTWARE\Telelogic\TAU\4.3\Integration: DOORSServerTimeoutDialog DOORSServerTimeoutValue   DOORSServerTimeoutDialog is used to control if the COM timeout dialogs should be displayed or not. If the value is 0 the dialogs are not displayed. If the value is 1 they are displayed. The default value is 1.   DOORSServerTimeoutValue is used to control the timeout (in milliseconds) before showing the dialog(s). This value is only meaningful when the dialogs are enabled. The default value is 45000.
PM00428 90842,100,838 TLOG#54669 Duplicate file references when loading DOORS/Analyst model When adding a model file referencing other files through model dependencies, multiple file references are no longer created in the project.
PM00460 90844,100,838 TLOG#54672 DOORS memory consumption increase massively when having DXL in default views and Tau open models The amount of memory used by DOORS when using the DOORS integration was drastically reduced.
PM00508 90878,100,838 TLOG#54695 UML-Objects that in DOORS have an Object Text get Change bars when opened in Tau UML elements in DOORS with Object Text are now marked as changed when loading the model in Tau only when the text has been changed.
PM00647 90426,100,838 TLOG#54747 The parser adds duplicate characters in green when pasting (informal) text containing keywords into symbols A problem with syntax highlighting of auto-qouted texts have been fixed.
PM01410 74568,999,744 TLOG#54991 TSC0452 errors encountered while generating C code generation project. Template transformation has been corrected to avoid occasional expansion of predefined C/C++ templates like CPtr, CArray, etc.
PM01409 15961,122,000 TLOG#54995 Not able to get back to the Automated merge result Remerge now works correctly for text text symbols and task symbols.
  91592,100,838 TLOG#55194 Please make it possible to manually type in the location for the DOORS Synchronization Module In the DOORS synchronization settings dialog, a path to the location can now be entered manually. If a valid path is entered, only that part of the database is read and displayed when pressing the "..." button. This drastically improves the performance with large databases.
PK91774 94890,999,706    TLOG#52190  Models get corrupted (duplicated guids) by simple Copy/Paste in Statechart diagrams  Sometimes models get corrupted (duplicated guids) by doing Copy/Paste in State chart diagrams. This has been fixed. APAR: PK91774  
PK92156 48241,122,000    TLOG#51852    XML read errors while trying to diff merge a Tau U2 file from Clear Case.  When trying to do diff merge a .u2 file from within Clear Case user would get an error. This has now been fixed by loading the single .u2 file into Tau (as an incomplete model). There is a risk in doing this that the model will now become corrupt. Please see Help for more information.
PK96140 85868,122,000    TLOG#53317    A Syntype definition from the U2p file is not updated on to the U2 file.  Now "constants" constraint is updated correctly from u2p file.
  58918,999,744   TLOG#49538  Huge delay (~10 mins) in loading models, opening/ editing large statemachines in TAU 4.0  A new option in the U2\Options\Editing\Lines is introduced in order to disable idle-time line routing when needed.

Interim Fix 1 (4.3.0.0_iFix001)
Link Date Released Status
APAR CR ID Synopsis
PK91774 TLOG#52190 Models get corrupted (duplicated guids) by simple Copy/Paste in Statechart diagrams

Initial Release (4.3)
Link Date Released Status
Call Ticket CR ID Synopsis Release Notes Text
2077548 TLOG#269 TIL errors for output from passive class method The usage of output actions in a method of a passive class is not supported by the C/Model Simulator code generator. Previously, TIL errors were generated when building such models. Now a UML-level check has been introduced to catch these errors on UML level.
4028569 TLOG#295 confusing text for TIL2323-warning when operator misses body Now, when generating C code, warning messages about unused definitions will not be printed.
7004609 TLOG#18346 Redeclared operations give (irrelevant?) errors that navigates wrongly A new semantic check for C code generation (including Model Simulator) has been added. It checks that an active class does not realize or require interfaces having operations with the same name. Previously such models would yield irrelevant TIL errors. Now compliance with this limitation is checked on UML level.
1046578 TLOG#18594 Undo and redo actions not performed successfully on model update in TAU G2 2.6 Message lines in sequence diagrams no longer disappear when using the "Update Model" command of Active Modeler followed by Undo and Redo.
6002164 TLOG#19429 File::Close in Menu option does not function as per the general functionality File::Close in the Menu option now function as per the general functionality, for the .u2 file
7006445 TLOG#20412 TAU becomes extremely slow after code generation. Previously the performance of Tau could deteriorate after code has been generated for a large model. This has now been improved to get better performance.
6005942 TLOG#21832 Error in signal routing In previous versions of Tau the C/Model Simulator code generation produced wrong code for models containing an active class with an internal structure. Implicit connectors were generated for non-behavior ports that had explicit connectors. This caused wrong execution of the generated code. Now generation of implicit connectors has been fixed to avoid creation of unnecessary connectors.
4032922 TLOG#22027 Documentation about CORBA Unions is wrong An error in the documentation about CORBA Unions has been corrected.
3024148 TLOG#22047 It is possible to split the inline frame for the loop option The separator line can be used in inline frames on a Sequence Diagram only with specific operators. Previously, the wrong usage of separator line was not checked by Tau. Now a special semantic check has been introduced to check that separator line is used with the appropriate operator.
4033501 TLOG#22112 Errors reporting Faulty connectors can not be navigated from (to the source) Previously when the semantic checker found an error/warning in a connector end it was not always possible to navigate from the error message to the connector end. This has now been solved by instead associating such error messages with the connector to which the connector end belongs.
7007981 TLOG#22113 Created Test Case from existing UC SQD doesnt bind Now Tau checks (and updates if it necessary) ImplementedSignature reference of test case.
4033948 TLOG#22360 Opening a u2 file instead of a ttw file makes the tool behave faulty It is now possible to close standalone files with File->Close menu.
4033978 TLOG#22362 It is not possible to close a u2 file opened by mistake It is possible to close standalone files
6008307 TLOG#23070 There is no way to locate definition SecuritySystemX in Internal Block diagram The semantic checks TSC0373 and TSC0096 were corrected to ignore unnavigable association ends and references in a sequence diagram. 
3025570 TLOG#23860 When we use xSignalLog fn we get errors NameNode is not a member of xPrsStruct. The error messages that were printed for the xSignalLog and xProcessLog functions from sctenv.c when compiling generated C code with the flag XSIGLOG defined have now been fixed.
6009969 TLOG#24077 Unable to dragdrop subjectsymbol qualified by colon from 1 UC diagram to another Now the semantic checker will not yield an error for a subject with an empty name.
7009787 TLOG#24212 The Wording of Semantic Checker message TSC4530 should be changed The message of the semantic check TSC4530 has been improved.
7009811 TLOG#24250 Name completion not working properly with dual screens Popup window is visible on secondary display
1050936 TLOG#24443 Minor document error in "Update file" to be corrected from "modelled to "modeled A minor error in the documentation about the TTDFileModel profile has been corrected.
1050953 TLOG#24780 Shouldn't be possible to send/receive signals to private(behaviour)port of class Now the semantic checker reports a warning if a connector is connected to a private behavior port.
1051224 TLOG#25117 Enter/Exit/Do actions should be more visible in the model Entry, do and exit compound action nodes are visible in the model browser now.
3026579 TLOG#25268 UML Increment Operator throws TIL Error The C code generator now supports the UML increment (++) and decrement (--) operators on integer types.
4037702 TLOG#25909 Name completion do not work in SQD states Name completion works in SQD states now.
1051771 TLOG#26084 Generated file artifacts for template classes have dependencies that won't bind The C++ code generator now generates file artifacts for template definitions more correctly. Previously the dependency generated for such a file artifact would contain a binding error.
1052195 TLOG#26900 Nextstate breakpoint refresh issue Previously when setting a breakpoint on a state symbol representing a next state, the breakpoint would not be immediately visible. This has now been fixed.
1052196 TLOG#26901 Statemachine breakpoint refresh issue Previously when setting a breakpoint on state machine elements, the breakpoint marker could be shown multiple times in the diagram. This duplication has now been fixed.
4040224 TLOG#28354 Please make the list for the 'Type' in the properties ordered The 'type' property is now sorted alphabetically.
4040401 TLOG#28516 Ports unbound and Connectors not shown after using 'Show Elements...' The behavior of the “Show Elements..” command for Composite Structure diagrams has been improved. Now this command shows parts with bound ports and connectors.
3030302 TLOG#29544 Creation of new Classes to be allowed both in Visual Studio and in Tau The synchronization of Tau C# project files with Microsoft Visual Studio has been improved.
4041379 TLOG#29616 Content of added u2-file faulty marked us changed Content of added u2-file do not marked as changed.
3029930 TLOG#29673 relation ship does not showup It is now supported to show attributes typed with templates as association lines when dragged & dropped to diagram.
7015062 TLOG#29840 Name mangling for operation names containing spaces visible in MV SQD trace Previously a mangled name would be shown in the Model Simulator for an operation or signal having a name that contains spaces. The mangled name would show up in the sequence diagram trace, as well as in the 'Signal' column in the Messages window. Both these problems have now been solved.
4042477 TLOG#30975 Please 'auto-activate' line handles when mouse-pointer is near Line handles are now displayed when mouse hover above a symbol and not only when the symbol is selected.
2060435 TLOG#31385 Display numbers for state chart diagrams in model view New tooltip is added for diagrams in the Model view
7016700 TLOG#31557 No type control in lifeline of SQD The semantic checker now checks that the type of a lifeline is the same as the type of an attribute that is represented by the lifeline.
7016913 TLOG#31700 Not possible to use macros without modifying generated files A new attribute "Additional Preprocessor Defines" has been added to the C Code Generator, AgileC Code Generator, Model Simulator and Model Explorer build artifacts. It is represented by a new text edit control in the Properties window where the user can specify additional compilation switches.
3032478 TLOG#31760 flexible number of operation parameters not working Now the C code generator (including Model Simulator) correctly supports operation parameters with non-single multiplicity.
3031779 TLOG#31902 Tau Model Verification undocks output tabs Output window could at some occasions be undocked automatically. This problem has been resolved.
6019914 TLOG#32625 Activity Line Verices placement not remembered Orthogonal lines don't change their shapes when symbols are moving on activity diagrams
7018073 TLOG#32821 Invalid error produced with name of XML Schema It is now possible to create XML schemas with non-alphanumeric characters in the name and generate Java code from the model without getting an error. Now a warning is printed instead.
7018663 TLOG#33471 Assigning an attr. with a class that has an inner structure give a TCC0810-error Previously when generating C code or using the Model Simulator, an assignment like “v =  p{i}” where ‘p’ is a part typed by an active class with internal structure could cause build errors if the active class did not have a constructor or the assignment was used within a for/while loop. Now these limitations are removed.
3034491 TLOG#33564 incrementor decrementor still does not function completely the right way The C code generator and Model Simulator have been fixed to always assign parameters from left to right during structure initialization with the (. params .) construct. This removes the previous platform specific behavior, when on some platforms initialization were from right to left, while on others it was from left to right. Now code is generated in such a way that on all platforms initialization works from left to right.
2082096 TLOG#34219 Operation calls from part to parent A C code generator specific semantic check has been added to yield a warning if code in a nested part calls an operation defined in an interface realized by a containing part without specifying the object to call explicitly.
3035134 TLOG#34372 set-sdl-coder results in build errors Added compile flag XRWF_JUSTCODER that modularises monitor functionality from serialization/coder functionality.
3035043 TLOG#34414 Query on URN not defined in TauBatch The support for URNs in TauBatch has been improved.
2082126 TLOG#34467 BUG in property editor when using XSD/WSDL The Property Editor drop down menu control now supports sorting based on the scoped name of the definitions shown in the list. This often makes it easier to find the correct definition to choose, and is now used when editing the type of a structural feature.
2056798 TLOG#34536 Virtual procedure parameters, not redefined in SDL import A semantic check related to a virtual/redefined operation having a generalization has been improved.
6022571 TLOG#36422 Link options - Active link end is an active target, not an active source "Active link end is an active target, not an active source" option has been renamed to "Reverse creation" to better explain it's purpose.
7021183 TLOG#36439 For merge, Save List with Ignore-Layout still shows some layout diff items Problems in "Save List" functionality are fixed.
6019808 TLOG#36739 Use Case based on requirement text The "Create Use Case" wizard has been improved to allow using attribute values, such as the Object Heading, as the use case name.
  TLOG#36922 SA_UML2: DeploymentSpecification symbol displayed with ‘artifact’ stereotype The meta model definition of DeploymentSpecification is now based on Artifact instead of Class. This is consistent with the UML standard. Old models using DeploymentSpecifications will be automatically updated to the new definition.
6022730 TLOG#36960 Cannot edit names for some of the requirements. Now it is possible to edit labels on remote definitions on diagrams.
7022709 TLOG#38202 Comments and not shown managed quotation marks gives text coloring errors Syntax highlighting of text could at some occasions be incorrectly offset. This problem has been resolved.
3038184 TLOG#39074 Package order after moving up/down can not be saved Packages order after moving up/down is saving now.
4050162 TLOG#39349 Error message contain two full stops at end A minor error in the error message printed for the Tcl command u2::LoadFile has been corrected.
5021348 TLOG#39618 It should be easier and more obvious to switch model filter view. A model view selector has been added to the model view.
4050769 TLOG#40056 Please improve the autolayout performance. Performance of autolayout command has been improved.
7024847 TLOG#40124 Code generated by the AD Simulator generates TSC0087 warnings Previously when simulating activities warnings related to stereotypes extending the wrong meta class would occur. This has now been fixed.
4050846 TLOG#40195 Please let the user start at 'Name edit mode' when creating a new diagram 'Name edit mode' is working when creating a new diagram.
2085980 TLOG#40877 Internal error: {...} after 1 or 2 Import Java source code runs The Tau Java support now works for a workspace with multiple projects.
2085896 TLOG#40888 Importing C++ into Tau 3.1 - Failed to load library for implemention of agent Syntax errors detected during C/C++ import are now printed correctly also on the Solaris/Linux platform. Previously those errors were suppressed on Solaris/Linux. No errors are printed to stderr any longer.
7025902 TLOG#41023 Strange graphical effect while dropping a signal in a signal receipt symbol When an element was dropped on a symbol, causing it to change appearance, a visual effect could be seen at some occasions. This problem is now solved.
3039267 TLOG#41097 pre and post condition stereotype applied to informal constant is not displayed A stereotype label was added to constraint symbols.
1061749 TLOG#41315 "Show all attributes/operations" as default for diagrams from imported C++ Regeneration support seems to be the only advantage from "new" diagram generators... And if or not class symbols are shown with attributes and operations now should depend on usual options "Show Attributes" and "Show Operations".
1062063 TLOG#41581 Unable to show all attributes/operations for multiple selection "Show/hide attributes/operations" is working for multiple selection.
4052302 TLOG#41913 Inline Frame Inline frame symbols appear above method call symbols on SQDE
7027402 TLOG#42121 Predefined diagram Generators fail with an internal error for Statemachines An erroneous error message related to class diagram generation has been rewritten.
3039867 TLOG#42294 how to remove the scope before action Now qualifiers for Activity Symbols can be completely hidden.
3039884 TLOG#42303 connection lines overlapping the symbols in the State Machine Diagram Line router works on big diagrams
7027709 TLOG#42336 Usecases from another packages are shown with parenthesis Use cases from remote packages are now shown without parenthesis.
7027551 TLOG#42348 'AgileEEGenerated' stereotype added to generated Java code The Java code generator has been fixed to properly handle special stereotypes. If a stereotype has no meaning from a Java point of view, it will not appear in the generated java code
4052834 TLOG#42590 Some class attributes imported from Together do not bind properly A problem in the Together importer has been fixed. Previously the type of some imported attributes would not bind correctly, but this has now been fixed.
4052809 TLOG#42599 Create presentation (include lines) por defecto An option have been added to make is possible to choose if lines should be created or not created as a result of a drag & drop operation from model view to a diagram.
3040106 TLOG#42708 Core Dumps for activity simulation A crash related to Connector symbols used in activity simulation models has now been fixed.
3040137 TLOG#42771 TAU can not show stereotype if there is an hyperlink All stereotypes on part symbols appear
1063531 TLOG#42772 stereotype not showing on element after reloading the model All stereotypes on part symbols appear
7028300 TLOG#42873 Passing Signal Type as a Parameter to an Operation A semantic check has been added which reports a warning if a signal is passed as the actual argument of an operation call.
1064121 TLOG#43303 copy&paste issue in text diagram An issue when copying and pasting text containing comments in a Text Diagram has been solved.
1064198 TLOG#43335 Automatic creation of one extra bracket on moving the signal to another package Previously when moving a signal between packages, Tau would sometimes add an extra bracket in diagrams where the signal was referenced. This problem has now been resolved.
3040679 TLOG#43720 A part cannot have more than one multiplicity range. The semantic check TSC3007 (concerning range checks for parts) is now only checked when generating C code or using the Model Simulator.
7029191 TLOG#43736 Impossible to set some breakpoints under the verifier Previously when setting a breakpoint on some kinds of actions in the Model Simulator, an error message would be printed. This has now been fixed.
7029397 TLOG#43926 The '{SysML View}' information removed from Model View under certain conditions Project nodes in the Model view don't lose active view's name anymore when saving.
2088698 TLOG#44205 HTML Model Browser file names are too long A new naming scheme was implemented for the Model Browser to avoid long directory and file names.
4053836 TLOG#44280 Trying to draw a message from an unbound Lifeline messes up the tool Now an unbound life line cannot be used as the source or target of a line.
2088687 TLOG#44345 Add-in that allows them to display security classification It is now possible to set a diagram heading and footer with for example security classification.
7029841 TLOG#44402 Code generation error when having a combination of factors The file GenerationResult.u2 could previously sometimes contain invalid XML when generated by the C code generator. This problem has now been solved.
7030104 TLOG#44619 Check All reports invalid warnings for child classes The semantic check TSC0396 (analysis of unreachable states) has been improved to now also handle statemachine redefinitions.
4054227 TLOG#44748 validator interface window values The upper bound of the Model Explorer bit-state depth parameter has been added to the Model Explorer user interface.
2089599 TLOG#44858 Tau 4.1 New Case - Properties Layout Your advertising can be placed here.
7030452 TLOG#44961 The 'Hide Qualifier' button do not work on Stereotype in Diagram Heading Hide qualifier button now works on diagram heading stereotypes as well.
1065672 TLOG#45111 Overlaped Signal symbols The behavior when drag-dropping signals onto input symbols and transition lines is now consistent.
7030641 TLOG#45117 Activity "name" property in Tau doesn't map to SA dictionary object name The name of an activity node created in Tau and stored in a System Architect encyclopedia, was not visible in System Architect. This is now resolved.
1065765 TLOG#45222 Ctrl+leftclick can not set anchor point on transitionline in state chart diagram It is now possible to add and remove a vertex on a transition line.
7029937 TLOG#45309 Please show the multiplicity of pure associations in the Properties panel It is now possible to see the multiplicity of an association's association end in the property page of an association.
2090101 TLOG#45329 TIL2371: Type mismatch for variable, formal parameter, When generating C code or using the Model Simulator on a model containing an attribute with a default value defined in an action, the error TIL2371 can sometimes be reported due to a limitation in the C code generator. Previously it was not possible to navigate from this error to the model which made the problem difficult to resolve. Now navigation between this error and the model has been enabled.
7031046 TLOG#45384 "CHILDKILLED 6972 SIGSEGV" error when importing wsdl generated by T The WSDL generator will now set the location to urn:undefined if it is not specified explicitly in the soap:address element.
1065990 TLOG#45459 how the Class operation can be synchronized with the DOORS module? Now all needed presentation elements have modified flag. So tau saves them in Doors.
1066058 TLOG#45529 DOORS Defect with checkDXL() effecting Analyst View Navigating a formal module in DOORS using the Analyst View no longer causes a memory leak.
7031206 TLOG#45537 Model View explorer icons don't properly reflect state of sync with DOORS The DOORS export indicator icon has been improved to more accurately reflect the current state of each element.
1066064 TLOG#45556 Indication to show the existence of comment symbols Symbols with hidden comments have an indication now. Double-click on the indicator creates the first hidden comment
2090357 TLOG#45565 Constraining BitString TIL error. A new semantic check has been added to detect constraints of a syntype of the BitString type, as this is not supported by the C code generator.
3042267 TLOG#45566 TSC0256 reported if syntype is constrained using 'size' The semantic checks detecting unsupported use of syntype constraints have been made more precise. Some errors have also been fixed in the handling of those syntype constraints which are indeed supported by the C code generator.
1066093 TLOG#45621 The "Show inherited literal elements" context menu option, doesn't Inherited literals are shown now
1066096 TLOG#45633 Crash when deleting a literal from a Primitive symbol, in some cases. Tau could at some occasions terminate when a deleting a feature from a symbol with compartments. This is now resolved.
1066087 TLOG#45660 when a diagram color is applied the "remove diagram prop" remains disabled The 'Remove diagram properties' operation will now change the color to the color defined in options when executed on a diagram.
1066063 TLOG#45686 Exit Name Overlap Word wrapping on return symbols' labels is now off.
7007520 TLOG#45851 Model Verifier run-time prompt is limited in number of characters shown Previously the Model Simulator run-time prompting dialog had a limitation in how many characters it could display. This could lead to the truncation of long texts. This problem has now been solved.
7031797 TLOG#46116 Model verifier corrupts PowerSets The Model Simulator now handles PowerSets correctly.
7031969 TLOG#46344 TAU G2 window is brought to the front automatically The tool's window is blinking when loaded project is modified outside (on Windows only).
4055513 TLOG#46477 'Check All' does not find unbound Signal Parameter An error in a diagram of the 'umlVerificationCoffeeMachine' example has been corrected.
4055578 TLOG#46575 Memory leaks with Automatically Generated Serialisation Routines Fixed a memory leak for the ascii coder library.
1066906 TLOG#46791 Object diagram in DOORS\Analyst I have added object diagram and stuff to analyst view metamodel.
4055341 TLOG#46935 Calling an operation in a class with inner structure fails The C translation of a public operation of an active class with innner structure has been corrected. This fix applies both to the C code generator and the Model Simulator.
7032701 TLOG#47215 Adding inline frame does not work Now refreching of symbols should work fine
4025369 TLOG#47422 Autolayout in Interaction Overview Diagrams does not work properly Autolayout has improved; also undo after doing "automatic layout" has been fixed.
1067654 TLOG#47754 Missing end tag of elements on Tau exported XMI file Tags are not missed while XMI export.
4056629 TLOG#48079 Last created descision branch causes errors because of faulty temporary indexes For the C code generator and Model Simulator the initialization of temporary variables which are used in transformation of complex index expressions has been corrected. Now initialization of temporary variables is not skipped when index expression is used in condition of decision action.
65031,999,000 TLOG#49022 Switch statements with more then one branch ignores the Default branch if test is an expression For the C code generator and Model Simulator the translation of a switch statement with more than one branch has been corrected. Now it does not ignore the default branch if the condition of the switch statement is a call expression.
56164,SGC,724 TLOG#49161 Test Framework and XSD Framework clashes so that building failes A problem in the usage of the <> stereotype in the TestingProfile has been fixed. A qualifier has been added to avoid name clashes with the predefined <> stereotype.
53367,100,838 TLOG#49279 Java Runtime Library 6 corrupt or incomplete Now Java runtime 6 libraries are loaded properly when creating a UML for Java Code Generation project
  TLOG#49501 GB18030: GB18030 characters will garbaged when copy to URL. 'Copy to URL' operation now also set the Unicode clipboard format.
50311,000,744 TLOG#49865 Tau MV build launched using Build -> Start Model Verifier crashes if stopped using Build -> Stop. An Application Builder crash that sometimes occurred when stopping a running Model Simulator has been fixed.
91314,999,706 TLOG#49975 11 TIL/TCC errors issued when having redefined inherited port Previously when generating C code for an active class which redefines inherited ports, the internal errors TIL2001 and TCC0800 were reported. This has now been fixed.
6007017 TLOG#22308 Multithreaded Generated application crash Several improvements were made in the TOR C++ library to better support multithreaded applications. NOTE: As part of the changes, the global eventManager variable is no longer available as it was not thread-safe. Models that use it should be updated to instead use the static functions of the EventManager class.
       
6011961 TLOG#26153 When build artifact disable instrumentation,VS project shouldnt have these macro For the <> stereotype new option fields have been added. Now it is possible to override the default output file name for the C++ project and to set up user-defined preprocessor defines and additional include directories. Also the Microsoft Visual Studio integration supports these new options and can update the corresponding Visual studio project settings.
6019808 TLOG#36739 Use Case based on requirement text The "Create Use Case" wizard has been improved to allow using attribute values, such as the Object Heading, as the use case name.
3038746 TLOG#39938 ER: Tau and MSVS needs better coupling The MS Visual Studio integration has been significantly improved. Many errors have been fixed and C++ projects are now exported to MSVS correctly including all project settings.   Note however that files created in a VS project do not get updated in Tau. Therefore before adding a new file in MSVS it should first be added in Tau.
4005184 TLOG#47222 When a class inherits from a class, one can not call methods inherited from pare Inheritance of both concrete and virtual methods is now supported for passive classes in the C backend.   Note that explicit or implicit upcasts of a passive class is still not supported, so ad-hoc polymorphism/dynamic dispatch (using derived classes through a super class interface) does not work.
4005076 TLOG#47223 Inheritance does not inherit methods Inheritance of both concrete and virtual methods is now supported for passive classes in the C backend.   Note that explicit or implicit upcasts of a passive class is still not supported, so ad-hoc polymorphism/dynamic dispatch (using derived classes through a super class interface) does not work.
3023232 TLOG#20323 TIL Errors are received if you use Own datatype in TAU G2. Now the Own type is supported by the C code generator and Model Simulator.   The Own type has the following operators:   1. {static} make(ItemSort).   Usage: Own x; x = Own::make(10);   2. {non-static} Set(ItemSort) Own x; x.Set(10);   3. {non-static} ItemSort Get() Usage: Own x; Integer k; k = x.Get();   IMPORTANT NOTE:   The type Own where T is a Class is translated to   newtype @ptr_T Ref( T) endnewtype;   newtype @TmplInst_OwnTR Own( @ptr_T) endnewtype;   If you need a value semantics, you should use the Value<> syntype: Own >. The Own > will be translated to   newtype @TmplInst_OwnTV Own( T) endnewtype;   The same mapping rules are used with other containers (String, Array, PowerSet).
91259,999,706 TLOG#50184 Nmake errors while trying to build the model.   Generated C code may result in "'x' : is not a member of 'T'" compile errors when: 1) An active class B inherits from active class A 2) Active class A contains statemachine, or gate or public variable or public operation 3) Active class B contains guard condition for the state * that references class B local variable This problem has been fixed.
2092793 TLOG#48091 Tau G2 4.2does not provide info on TIL errors Tau G2 4.2 does not provide complete info on TIL errors - a reference to model element is missing in the error message. This defect has been fixed.
03006,122,000 TLOG#49039 Tau web server needs to close due to a socket error: INVALID_SOCKET If the default Tau Web Server port is occupied when launching Tau, Tau would not start. This has been fixed.
2090302 TLOG#45424 Tau crashed while starting Model verifier Application Builder no longer crashes when starting the Model Verifier without an artifact.
2090300 TLOG#45393 Tau G2 doesn't support modifying OctetString data types in MV watch window It is now possible to edit octet string in the Watch window.
2090562 TLOG#45559 cannot inject message to MV     The Model Verifier no longer halts if signals with large parameters are sent into the system.

Table of Contents:


Fix Pack 2 (4.2.0.2)
Link Date Released Status
Call Ticket CR ID Synopsis Release Notes Text
2092793 TLOG#48091 Tau G2 4.2does not provide info on TIL errors Tau G2 4.2 does not provide complete info on TIL errors - a reference to model element is missing in the error message. This defect has been fixed.
03006,122,000 TLOG#49039 Tau web server needs to close due to a socket error: INVALID_SOCKET If the default Tau Web Server port is occupied when launching Tau, Tau would not start. This has been fixed.

Fix Pack 1 (4.2.0.1)
Link Date Released Status
Call Ticket PD Call Ticket Synopsis Release Notes Text
2090302 TLOG#45424 Tau crashed while starting Model verifier Application Builder no longer crashes when starting the Model Verifier without an artifact.
2090300 TLOG#45393 Tau G2 doesn't support modifying OctetString data types in MV watch window It is now possible to edit octet string in the Watch window.
2090562 TLOG#45559 cannot inject message to MV     The Model Verifier no longer halts if signals with large parameters are sent into the system.

Initial Release (4.2)
Link Date Released Status
Call Ticket PD Call Ticket Synopsis Release Notes Text
1047685 TLOG#19756 Spelling errors in error messages A few spelling errors in semantic checker messages were corrected.
4031792 TLOG#20555 Method calls in SQD get wrong return type when using 'Reference Existing' Previously when using "Reference Existing" for showing a method call in a sequence diagram, the return type would be incorrectly set. This has now been fixed.
7007005 TLOG#21034 Different behavior when class has active/passive class as array When generating C code, composite attributes typed by passive classes are not automatically initialized. A new semantic check has been added to detect and warn about such cases.
4032242 TLOG#21036 Faulty error message when having passive part with initial count See TLOG#21034.
4023780 TLOG#21708 method call spanning many lifelines is not pasted correctly Documentation is updated. The new sub section "Copying a messages" is added in UML Modeling -> UML Language Guide -> Scenario Modeling -> Message.
2074886 TLOG#21755 Property Editor - change name of type name to null does not work The wrong context menu could at some occasions be displayed in the property editor. This is now resolved.
7004023 TLOG#21916 Make Space does not move separator line Make space' command now also move separator lines in sequence diagrams.
4033576 TLOG#22147 No error given when having an operation as trigger in C++ code generation When having an operation as trigger in a model intended for C++ code generation an error is now reported since this construct is not supported by the C++ code generator.
7008912 TLOG#23159 TIL2066: Several matches Previously when generating C code incorrect code would be generated if an attribute and its type had the same name. This has now been solved, and such models are now correctly translated to C.
4037698 TLOG#25910 Name completion do not work properly when entity name contain spaces Now name completion inserts unparsed name of selected definition (i.e. if it contains spaces, it will be quoted).
7011486 TLOG#26089 Solaris only: Painting Error With Port Interface Symbols. On Solaris platform there was a painting errors on port interface symbols. This is now corrected.
4040176 TLOG#28297 Semantic checker does not find errors in 'Conditional' expressions When generating C, C++ and Java code, binding errors in conditional expressions are now detected and reported.
7014038 TLOG#28658 Call to non-public operation to caught by the semantic checker. TIL2088-error A call to a non-public operation is now caught by the semantic checker.
4041083 TLOG#29226 Using 'remove' on a Charstring gives TIL2371 error Support for "remove" Charstring operator has been added to C code generators, Model Verifier and Validator.
7014678 TLOG#29432 Using named return parameter from an Operation gives TIL2312 errors A new semantic check was implemented to detect incorrect usage of named return parameters.
2081239 TLOG#30470 Using 'unsigned long long int' results in TIL Errors Support for 'unsigned long long int' and 'long long int' types has been implemented in C and AgileC code generators, ModelVerifier and Validator. XNOUSE_LONG_LONG compile switch has been added - it controls whether long long type is used in the generated code. For the code generators this compile switch is generated automatically to auto_cfg.h file. If UML model does not use 'unsigned long long int' and 'long long int', #define XNOUSE_LONG_LONG will be added to auto_cfg.h. For ModelVerifier and Validator, this compile switch is never set and long long types are always available in the generated code.
6017412 TLOG#30552 In the shortcut window,symbols doesnt grey out. Disabled buttons in the "Create diagram element" toolbar is now grey out when shown in the shortcut window.
3031780 TLOG#31081 XML Parser errors Previously when generating C code with the option enabled to produce a "Result of C generation" package, the XML in this .u2 file would contain errors if the path to generated C files contains a character that would need escaping in XML (such as '&'). This problem has now been fixed.
6017484 TLOG#31207 Tau G2 Char types The definition of unsigned_char from BasicCTypes.pr has been updated and now it is defined as 'unsigned char' in generated code.
4044599 TLOG#32963 The semantic checker do not work give proper feedback with on a java project Semantic checks run on models for Java code generation are now correctly summarized (informing about the total number of errors and warnings found).
3033694 TLOG#32972 Incorrect Parameter Evaluation Order The C Code Generator has been updated to ensure that all parameters in an operation call are evaluated from left to right. This is true for operations defined in UML as well as for external operations. This applies for all versions of the C code generator, regardless of which target compiler that will be used, except for Agile CCG for which parameter evaluation order for external function calls still is compiler dependent. Note, that for Agile CCG parameter evaluation order for external function calls is still compiler dependent.
7020025 TLOG#34933 Testing Profile name clashes Semantic checks specific for the Testing Profile will now detect erroneous name clashes.
3035379 TLOG#35078 Text overflows the tab on package when label position stereotype is applied Package symbol tab appearance has been improved, and package label is now placed inside the symbol as default.
7020574 TLOG#35834 while doing a check-all error :TCS2007 occurs A problem related to the inline type of actors, subjects etc. which is created automatically by drag/drop has been fixed.
6022457 TLOG#36443 Tau 3.1 Seq Diagram Trace (start_msc 2) error Positioning of sequence diagram symbols during trace has been improved.
6022712 TLOG#36684 Update from DOORS doesn't reflect changes to module names in DOORS When the name of an imported DOORS module is changed in DOORS, the new name is now properly displayed in Tau after doing a Full Update.
7022481 TLOG#38002 'End'-key do not work properly in State symbols Text editing in diagrams has been improved to better support Home and End keys.
7023455 TLOG#38866 The Model Verifier can not handle two signals with different signatures Signals with the same name but with different signatures are now supported in ModelVerifier. Signals are identified by name + list of formal parameter types. In ModelVerifier GUI Signal drop-down list and in trace messages displayed signal names are followed by formal parameter list, for example, testSignal(Integer).
7023624 TLOG#39073 TAU Merge Crashes A crash while doing automatic merge have been fixed.
7023493 TLOG#39174 Uncomplete SQD built with the HTML report See TLOG#42238.
4050153 TLOG#39348 Compare/Merge from command line (Synergy Int) do not handle files with spaces The U2FileUtility now supports spaces in file names.
4050162 TLOG#39349 Error message contain two full stops at end The U2FileUtility now supports spaces in file names.
7023896 TLOG#39369 Tau Consistenly Crashes when doing a 3-way Merge Tau no longer crash while doing a 3-way merge.
2084244 TLOG#39370 Tau 4.0 documentation error The UML Tutorial now has the right version number.
4050352 TLOG#40055 The autolayout algorithm do not take the maximum diagram size into consideration A warning is now shown in "Messages" report tab if some elements are placed outside diagram bounds.
4050875 TLOG#40212 Quotation marks not inserted by Auto Completion Quotation marks is added automatically if needed for Accept Event, Send Signal, Actor, State, Signal Receipt, Signal Sending and Save symbols.
7025188 TLOG#40376 Deleting class attributes does not actually delete the attribute Attribute is deleted from SA repository when using the context menu "Delete attribute" now.
7025204 TLOG#40378 Placing a UML2 SQD message by single-click place the message faulty Positioning of message lines created with single-click feature are now positioned better.
7025258 TLOG#40404 UML2: The X and ? buttons in the color pallet dialog freeze SA X and ? In color palette dialog button no longer freeze the tool.
4051068 TLOG#40408 'Check All' gives 6 warnings on class symbol in new C# model All C# and Java collection types now inherit from ::Predefined::Collection, making them easier to use at UML level.
4051103 TLOG#40447 Documentation about DOORS baselines needs to be updated  
1060994 TLOG#40519 Update TAU help document New example added to the "Types representing signals" section in documentation.
7025366 TLOG#40553 Bad parameter value for a signal traced by the Verifier Support for signals with the same name but different signatures has been implemented in SequenceDiagram Trace. The sequence diagram now shows the correct actual parameter values for such signals.
1061759 TLOG#41301 What does "createEntityFeatureLabels" do? CreateEntityFeatureLabels parameter given to certain diagram generators now create attributes and operations in class symbols.
1062466 TLOG#41928 Tau 4.0 help doc - typo Cmp Documentation no longer use the abbreviation for the word compare.
4052335 TLOG#41968 SA stored model exported to DOORS do not keep information when closed/reopened When using the System Architect and DOORS integration simultaneously, could at some occasions loose information. This is now resolved.
3026051 TLOG#41983 External(operation/otherwise)names should not be mangled by the code generator A new option was added to all C build artifacts (including the Model Verifier) which allows external operations not to be name mangled.
4052345 TLOG#41989 Not possible to create an actor from SA VBA using the Tau API It is possible to create an actor via Tau API now.
4052440 TLOG#42116 'SYNERGY - Merge project' gives Java errors The Java error for the Synergy - Merge project has been corrected in ListProjectCommand on Java integration side.
7027401 TLOG#42120 Tau crash The possible cause for a crash have been fixed.
7027352 TLOG#42223 The tool never stops on a SQD testcase In rear occasions test execution would continue even when verdict is printed. Now the test process is terminated when verdict is printed.
7027576 TLOG#42238 The HTML Browser do not publish the complete diagram HTML Browser could at some occasions generate a cropped diagram. The problem is resolved.
7027757 TLOG#42373 Icon and LabelPosition stereotypes still visible in Tau 4.1 Icon and LabelPosition stereotypes are now invisible.
7027852 TLOG#42452 Not possible to create multiple Dependency links with diagrams open Creation of dependancy link with multiple targets is now supported with the End link command.
4052823 TLOG#42551 Compartment text hidden by 'Active class line' Text in compartments could be overdrawn with the active class lines. Text is now placed between active class lines.
4052824 TLOG#42552 Connector end text overlap the port Positioning of Connector Line's end text labels was improved.
4052866 TLOG#42637 Autolayout in Composite Structure Diagrams destroyed by Autolayout Line routing in Composite structure diagrams has been improved.
7028268 TLOG#42880 SysML model checker does not acknowledge stereotype inheritance SysML specific semantic checks now take inheritance into account.
1063523 TLOG#42954 How to access system call public func from a child class (composition) A new semantic check was implemented to give a warning if an attribute is defined in an active class which has parts (directly, or indirectly through inheritance). The reason is that such a construct cannot always be translated to correct C code.
7028689 TLOG#43248 Tau crash when drawing ports using SA-Tau integration Tau could terminate unexpectedly when creating multiple ports on a class while using the System Architect integration.
1064122 TLOG#43294 Ctrl+click can not locate the definitions when “Show/Hide is off Ctrl+Click now works properly to locate elements when "Show/Hide commands" are enabled.
4053150 TLOG#43317 errors when building and the SA Integration is enabled Conflicting elements in System Architect integration has been removed.
3040655 TLOG#43478 Warning messages while dragging activity to Interaction Overview Diagram An error in the definition of the <> stereotype, which would cause a warning, has now been corrected.
2089183 TLOG#44650 The folder are 0 BUG? Sometimes DoDAF view would contain some unnecessary "0" folders. These folders will not appear in DoDAF view anymore.

[{"Product":{"code":"SSYQGX","label":"Rational Tau"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Documentation","Platform":[{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"4.2;4.2.0.1;4.2.0.2;4.3;4.3.0.1;4.3.0.2;4.3.0.3;4.3.0.4;4.3.0.5;4.3.0.6","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
17 June 2018

UID