IBM Support

PM94729: STUBS LOCATED IN FOLDERS CANNOT BE PUBLISHED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Attempts to publish stubs from folders within Rational
    Integration Tester (RIT) projects to Rational Test Control Panel
    (RTCP) fail with no error reported.
    
    STEPS TO REPRODUCE:
    
    1. Create a RIT project
    2. Create a service component and operation in Architecture
    School Logical View
    3. Create two seroperations within the main component
    4. Create a folder under one the second operation in Test
    Factory
    5. Create a stub under the first operation
    6. Create a stub within the folder of the second operation
    7. Publish stubs to RTCP - pubish of two stubs appears to be
    successful
    
    EXPECTED RESULTS:
    
    Both stubs are visible in RTCP
    
    ACTUAL RESULTS:
    
    Only the stub created directly under the operation is visible.
    The stub within the folder has not been published.
    
    WORKAROUND:
    
    1. Move the stub directly under the operation in Test Factory.
    2. Republish to RTCP.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Test Virtualization Server             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * If a user created a subfolder under a Service Component in   *
    * Rational Integration Tester, created a stub inside that      *
    * subfolder and then published the stub to Rational Test       *
    * Control Panel then, although the publication process would   *
    * complete successfully the stub would not show in the RTCP    *
    * dashboard.                                                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to version 8.5.0.2 of Rational Integration Tester    *
    * where this problem has been resolved                         *
    ****************************************************************
    

Problem conclusion

  • This problem was resolved in Rational Integration Tester 8.5.0.2
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM94729

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-08-08

  • Closed date

    2013-09-27

  • Last modified date

    2013-09-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: