Error description
Recording on HTTP traffic does NOT handle Content-Length: 0 correctly. The symptom is: When recording a HTTP reply message which has a 302 response code and Content-Length in HTTP response header is 0, in the 302 response message body which should be empty, it has a whole response message which has a set of HTTP response head and message body, but no independent response answered to the redirected request after 302 response. The response for the redirected request is exactly in the 302 response message body.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Rational Integration Tester with pCap * **************************************************************** * PROBLEM DESCRIPTION: * * If a user is recording HTTP traffic in Rational Integration * * Tester's Recording Studio perspective using pCap (packet * * capture, as opposed to the HTTP proxy recording method) and * * a reply of Content-Length 0 is recorded then subsequent * * recorded messages are corrupted. * **************************************************************** * RECOMMENDATION: * * Users can switch to HTTP proxy recording (this requires * * deployment of the Rational Integration Tester proxy from the * * Platform Pack) or upgrade to version 8.5.0.1 of Rational * * Integration Tester. * ****************************************************************
Problem conclusion
This problem has been resolved in Rational Integration Tester 8.5.0.1. The problem was caused by an assumption that a response length would always be greater than zero.
Temporary fix
Comments
APAR Information
APAR number
PM93382
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
801
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-07-18
Closed date
2013-08-29
Last modified date
2013-08-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSY
UP
Document Information
Modified date:
01 November 2021