IBM Support

JR45487: Teradata Connector - read job fails with Framework returned error for conversion from string to calendar.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A DataStage job contains Teradata stage which maps a string
    value to timestamp, and the job ran ok.
    After using the Connector Migration Tool to convert the
    Teradata stage to a Teradata Connector stage, the job fails with
    error:
    Framework returned error for conversion from string to calendar:
    Inappropriate type code for field
    Since the stage has setup the Timestamp field as a string in the
    design schema, the Teradata Connector stage behaved as it was
    designed by throwing a conversion error.  However, since both
    the string and calendar data (date, time, and timestamp) are
    known formats they can be converted from one form to another
    with a code change to the Teradata Connector and Server
    framework to implement that functionality.
    

Local fix

Problem summary

  • Teradata Connector - read job fails with Framework returned
    error for conversion from string to calendar.
    

Problem conclusion

  • The Customer is treating Timestamp field as string in his design
    schema. So, the TDCC is behaving as expected by throwing a
    conversion error.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR45487

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    870

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-01-21

  • Closed date

    2013-02-26

  • Last modified date

    2013-07-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R850 PSY

       UP

  • R870 PSY

       UP

  • R910 PSY

       UP