IBM Support

What Are The Define Message Levels In Debug Tracing For CONNECT:Enterprise UNIX? (SCI34058)

Question & Answer


Question

What Are The Define Message Levels In Debug Tracing For CONNECT:Enterprise UNIX? (SCI34058)

Cause

Answer

General Guideline
Debug Level
1 Quiet, Errors only
5 General flow, SIPS name but no SIPS content (5 is a good level for this)
9 SIPS content, but truncated data records
'9' Is the recommended debug level in most cases. New installs use this
for ceustartup.trace.

Note: Anything 10 or over should only be done at the request of SCI
Support
        10                More mailbox flow
        20                Even more mailbox messages
        50                Full SIPS data records traces
        90                Semaphores, Shared memory messages (obnoxious)
        99                Real obnoxious
        100                Every SIPS record dumped piece by piece!

Note: This information is currently not documented because the modules are being redraft into a conformity with a standard. This will be documented in a later release.

[{"Product":{"code":"SSFVK3","label":"IBM Sterling Connect:Enterprise for UNIX"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Not Applicable","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Historical Number

PRI21602

Product Synonym

[<p><b>]Fact[</b><p>];CONNECT:Enterprise UNIX;Release 1.3.00 [<br/>] SCI34058;[<p><b>]Goal[</b><p>];FAQ: What Are The Define Message Levels In Debug Tracing For CONNECT:Enterprise ;UNIX?

Document Information

Modified date:
17 December 2019

UID

swg21550794