IBM Support

webMethods Knowlegebase : Service virtualization failed in CentraSite Adapter (1761422)

Troubleshooting


Problem

IS 8.2.2 core fix 10; CentraSite : 8.2.2.36

Service virtualization failed in CentraSite Adapter package.

Used template: Import/Export Archives, Services, XML Schemata

Action: Import/Attach to Service Asset

When the import template is executed for a WSDL with VirtualService is set to "true", the following error occurs:

"Adapter Runtime: Error Logged. See Error log for details. Error: [ART.117.4002] Adapter Runtime (Adapter Service): Unable to invoke adapter service Adapter_v0r1.adapter:importWsdl.

INMJRE0049: Cannot modify object type classification"

Logs from service return :

"Launch started: 2015-01-05 15:23:18.889

Configuration name: importWsdl (2)

Configuration location: E:/workpace/.metadata/.plugins/org.eclipse.debug.core/.launches/importWsdl (2).launch

Could not run 'importWsdl'

com.wm.pkg.art.error.DetailedServiceException: [ART.117.4002] Adapter Runtime (Adapter Service): Unable to invoke adapter service Adapter_v0r1.adapter:importWsdl.

INMJRE0049: Cannot modify object type classification

com.wm.pkg.art.error.DetailedServiceException: [ART.117.4002] Adapter Runtime (Adapter Service): Unable to invoke adapter service Adapter_v0r1.adapter:importWsdl.

INMJRE0049: Cannot modify object type classification

at com.wm.pkg.art.error.DetailedServiceException.create(DetailedServiceException.java:126)

at com.wm.pkg.art.error.DetailedServiceException.create(DetailedServiceException.java:117)

at com.wm.pkg.art.error.DetailedServiceException.create(DetailedServiceException.java:104)

at com.wm.pkg.art.ns.AdapterServiceNode.invokeService(AdapterServiceNode.java:388)

at com.wm.pkg.art.ns.ARTNSService.baseInvoke(ARTNSService.java:54)

at com.wm.app.b2b.server.invoke.InvokeManager.process(InvokeManager.java:643)

at com.wm.app.b2b.server.util.tspace.ReservationProcessor.process(ReservationProcessor.java:41)

at com.wm.app.b2b.server.invoke.StatisticsProcessor.process(StatisticsProcessor.java:44)

at com.wm.app.b2b.server.invoke.ServiceCompletionImpl.process(ServiceCompletionImpl.java:243)

at com.wm.app.b2b.server.invoke.ValidateProcessor.process(ValidateProcessor.java:51)

at com.wm.app.b2b.server.invoke.PipelineProcessor.process(PipelineProcessor.java:171)

at com.wm.app.b2b.server.ACLManager.process(ACLManager.java:282)

at com.wm.app.b2b.server.invoke.DispatchProcessor.process(DispatchProcessor.java:30)

at com.wm.app.b2b.server.AuditLogManager.process(AuditLogManager.java:365)

at com.wm.app.b2b.server.invoke.InvokeManager.invoke(InvokeManager.java:547)

at com.wm.app.b2b.server.invoke.InvokeManager.invoke(InvokeManager.java:386)

at com.wm.app.b2b.server.ServiceManager.invoke(ServiceManager.java:244)

at com.wm.app.b2b.server.comm.DefaultServerRequestHandler.handleMessage(DefaultServerRequestHandler.java:119)

at com.wm.app.b2b.server.HTTPMessageHandler.process(HTTPMessageHandler.java:160)

at com.wm.app.b2b.server.HTTPDispatch.handleRequest(HTTPDispatch.java:186)

at com.wm.app.b2b.server.Dispatch.run(Dispatch.java:368)

at com.wm.util.pool.PooledThread.run(PooledThread.java:131)

at java.lang.Thread.run(Thread.java:662)

Caused by: javax.resource.ResourceException: INMJRE0049: Cannot modify object type classification

at com.softwareag.wm.adapter.soa.ISFlowWrapperTemplate.execute(ISFlowWrapperTemplate.java:452)

at com.wm.adk.cci.interaction.WmInteraction.execute(WmInteraction.java:76)

at com.wm.pkg.art.ns.AdapterServiceNode.invokeService(AdapterServiceNode.java:338)

... 19 more

Launch completed: 2015-01-05 15:23:38.822"

The Adapter Trace shows the following:

"2015-01-05 15:48:34 CET [ADA.9001.9999I] Begin CentraSite Adapter Transaction

2015-01-05 15:48:34 CET [ADA.9001.9999I] Specified IS flow path (LOG DEBUG): pub.centrasite.importer

2015-01-05 15:48:34 CET [ADA.9001.9999I] Specified IS flow name: registerServiceFromWSDL

2015-01-05 15:48:34 CET [ADA.9001.9999I] Passing CentraSite Registry Connection to IS Flow using field name: centraSiteConnection

2015-01-05 15:48:34 CET [ADA.9001.9999C] INMJRE0049: Cannot modify object type classification---com.centrasite.jaxr.infomodel.RegistryObjectImpl.addClassificationInternal(RegistryObjectImpl.java:837)

2015-01-05 15:48:34 CET [ADA.9001.9999I] Ignoring to close CentraSite Connection (id=1216858179) managed by ART

2015-01-05 15:48:34 CET [ART.0114.1007E] Adapter Runtime: Error Logged. See Error log for details. Error: [ART.117.4002] Adapter Runtime (Adapter Service): Unable to invoke adapter service Adapter_v0r1.adapter:importWsdl..

INMJRE0049: Cannot modify object type classification

2015-01-05 15:48:34 CET [ADA.9001.9999I] Rollback CentraSite Adapter Transaction"

Document Location

Worldwide

[{"Line of Business":{"code":"LOB77","label":"Automation Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSVYEV","label":"IBM webMethods Integration"},"ARM Category":[{"code":"a8mKe00000000AQIAY","label":"webMethods Integration Server (PIE)"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Windows 7 Professional Edts"}],"Version":"8.2.2"},{"Line of Business":{"code":"LOB77","label":"Automation Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSFIWYE","label":"IBM webMethods B2B"},"ARM Category":[{"code":"a8mKe00000000AQIAY","label":"webMethods Integration Server (PIE)"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Windows 7 Professional Edts"}],"Version":"8.2.2"},{"Line of Business":{"code":"LOB77","label":"Automation Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSQG2X","label":"IBM webMethods Managed File Transfer"},"ARM Category":[{"code":"a8mKe00000000AQIAY","label":"webMethods Integration Server (PIE)"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Windows 7 Professional Edts"}],"Version":"8.2.2"}]

Log InLog in to view more of this document

This document has the abstract of a technical article that is available to authorized users once you have logged on. Please use Log in button above to access the full document. After log in, if you do not have the right authorization for this document, there will be instructions on what to do next.

Historical Number

Patch Level 10

Document Information

Modified date:
20 March 2025

UID

ibm17220003