IBM Support

VIOS 4.1.0.30 Fix Pack Release Notes

Fix Readme


Abstract

Release notes for the 4.1.0.30 VIOS Fix Pack release

Content

VIOS 4.1.0.30 Release Notes

Package Information

PACKAGE: Update Release 4.1.0.30
IOSLEVEL: 4.1.0.30

VIOS level is

The AIX level of the NIM Master level must be equal to or higher than

Update Release 4.1.0.30

AIX 7300-02-02

General package notes

Be sure to heed all minimum space requirements before installing.

Review the list of fixes included in Update Release 4.1.0.30

To take full advantage of all the functions available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 4.1.0.30.

Microcode or system firmware downloads for Power Systems

If the VIOS being updated has filesets installed from the VIOS Expansion Pack, be sure to update those filesets with the latest VIOS Expansion Pack if updates are available.

Update Release 4.1.0.30 updates your VIOS partition to ioslevel 4.1.0.30. To determine if Update Release 4.1.0.30 is already installed, run the following command from the VIOS command line.

$ ioslevel

If Update Release 4.1.0.30 is installed, the command output is 4.1.0.30.

Note: The VIOS installation DVDs and the level of VIOS preinstalled on new systems might not contain the latest fixes available. It’s highly recommended that customers that get the physical GA level (i.e., 4.1.0.00) to update to the electronic GA levels (i.e., 4.1.0.30) as soon as possible. Missing fixes might be critical to the proper operation of your system. Update these systems to a current service pack level from Fix Central.

Upgrade to VIOS 4.1.x

  • Existing VIOS systems with supported versions of 3.1.x.y can be upgraded to VIOS version 4.1.0.00 (DVD image) or 4.1.0.30 (Flash image) using viosupgrade tool . Although it is recommended to be on VIOS 3.1.4.30 or later SP level before upgrading to VIOS 4.1.x level.

  • VIOS systems with SSP configuration must be on 3.1.3.x or later level before upgrading to 4.1.x level or adding 4.1.x nodes into cluster.

  • If Active Memory Sharing (AMS) is configured on the VIOS, it should be un-configured before upgrading. You may refer the link on how to un-configure.

  • Before upgrading, you may read the viosupgrade blog in PowerVM Community which explains various scenarios.

  • After an upgrade to VIOS 4.1.0.0 or VIOS 4.1.0.30, the padmin user may be unable to login due to premature password expiration. Before running viosupgrade user should apply the ifix to avoid the issue. Please refer the support document for more details.

For Customers using NVMe Over Fabric (SAN) as their Boot Disk

Booting from NVMeoF disk may fail if certain fabric errors are returned, hence a boot disk set up with multiple paths is recommended.  In case there is a failure to boot, the boot process may continue if you exit from the SMS menu. Another potential workaround is to discover boot LUNs from the SMS menu and then retry boot.


 

Note

If the Virtual I/O servers are installed on POWER10 systems and configured with “32Gb PCIe4 2-Port FC Adapter, Feature Code(s) EN1J and EN1K”, then the requirement is to update the adapter microcode level to 7710812214105106.070115 before updating the Virtual I/O server to 4.1.0.30 level.

Please refer to the release notes at this link

4.1.0.30 New Features

VIOS 4.1.0.30 adds the following new features:

Security enhancements

  • Supports Trusted Execution, Trusted Update and Secure Boot.
  • Supports new stronger default password (SSHA-256) and out of the box long password support (255 character limit)
  • Data protection with LVM encryption for rootvg and dump devices.       
  • Services that are not secure like rexec, rsh are removed. Telnet / ftp service are disabled. Users can enable telnet / ftp service if required.
  • ksh93 is used as the default ksh in VIOS commands and scripts

viosupgrade enhancements

The major enhancements done in viosupgrade in this release are as follows.

  • Added new option -F devname to preserve the device names for vfchost adapter devices, fcnvme, nvme, fscsi, iSCSI devices and network adapter devices.
  • The new options “-k” and “-o rerun” is added which is specific to pre-restore script execution.

viosbr enhancements

Restore of all the PV backed VTDs if the same PV is mapped to multiple vhosts.

Others

Enhancement in alt_root_vg command, to run it in phases. This enhancement allows the alt_root_vg command to separate the cloning phase from the update phase.

Hardware Requirements

Please check this link for supported hardware.

Known Capabilities and Limitations

The following requirements and limitations apply to Shared Storage Pool (SSP) features and any associated virtual storage enhancements.

Requirements for Shared Storage Pool

  • System requirements per SSP node:
    • Minimum CPU: 1 CPU of guaranteed entitlement
    • Minimum memory: 4GB
    • Storage requirements per SSP cluster (minimum): 1 fiber-channel attached disk for repository, 10 GB
    • At least 1 fiber-channel attached disk for data, 10GB

Limitations for Shared Storage Pool

Software Installation

  • When installing updates for VIOS Update Release 4.1.0.30 participating in a Shared Storage Pool, the Shared Storage Pool Services must be stopped on the node being upgraded.

SSP Configuration
 

Feature

Min

Max

Number of VIOS Nodes in Cluster

1

16*

Number of Physical Disks in Pool

1

1024

Number of Virtual Disks (LUs) Mappings in Pool

1

8192

Number of Client LPARs per VIOS node

1

250*

Capacity of Physical Disks in Pool

10GB

16TB

Storage Capacity of Storage Pool

10GB

512TB

Capacity of a Virtual Disk (LU) in Pool

1GB

4TB

Number of Repository Disks

1

1

Capacity of Repository Disk

10GB

1016GB

Number of Client LPARs per Cluster

1

2000

*Support for additional VIOS Nodes and LPAR Mappings:

Prerequisites for expanded support:

  • Over 16 VIOS Nodes requires that the SYSTEM (metadata) tier contains only SSD storage.
  • Over 250 Client LPARs per VIOS requires each VIOS have at least 4 CPUs and 8 GB memory.

Here are the new maximum values for each of these configuration options, if the associated hardware specification has been met:
 

Feature

Default Max

High Spec Max

Number of VIOS Nodes in Cluster

16

24

Number of Client LPARs per VIOS node

250

400

Other notes:

  • Maximum number of physical volumes that can be added to or replaced from a pool at one time: 64
  • The Shared Storage Pool cluster name must be less than 63 characters long.
  • The Shared Storage Pool pool name must be less than 127 characters long.
  • The maximum supported LU size is 4TB, however for high I/O workloads recommendation is to use multiple smaller LUs as it will improve performance. For example, using 16 separate 16GB LUs would yield better performance than a single 256GB LU for applications that perform reads and writes to a variety of storage locations concurrently.
  • The size of the /var drive should be greater than or equal to 3GB to ensure proper logging.


Network Configuration

  • Uninterrupted network connectivity is required for operation. i.e., the network interface used for Shared Storage Pool configuration must be on a highly reliable network which is not congested.
  • A Shared Storage Pool configuration can use IPV4 or IPV6, but not a combination of both.
  • A Shared Storage Pool configuration should configure the TCP/IP resolver routine for name resolution to resolve host names locally first, and then use the DNS. For step by step instructions, refer to the TCP/IP name resolution documentation in the IBM Knowledge Center.
  • The forward and reverse lookup should resolve to the IP address/hostname that is used for Shared Storage Pool configuration.
  • It is recommended that the VIOSs that are part of the Shared Storage Pool configuration keep their clocks synchronized.


Storage Configuration

  • Virtual SCSI devices provisioned from the Shared Storage Pool may drive higher CPU utilization than the classic Virtual SCSI devices.
  • Using SCSI reservations (SCSI Reserve/Release and SCSI-3 Reserve) for fencing physical disks in the Shared Storage pool is not supported.
  • SANCOM will not be supported in a Shared Storage Pool environment.


Shared Storage Pool capabilities and limitations

  • On the client LPAR Virtual SCSI disk is the only peripheral device type supported by SSP at this time.
  • When creating Virtual SCSI Adapters for VIOS LPARs, the option "Any client partition can connect" is not supported.
  • VIOSs configured for SSP require that Shared Ethernet Adapter(s) (SEA) be setup for Threaded mode (the default mode). SEA in Interrupt Mode is not supported within SSP.
  • Client LPARs are not supported if they use JFS as their filesystem.  If JFS is used, there is a risk of data corruption in the event of a network outage.  JFS2 and other file systems are unaffected by this issue.

Installation Information

Pre-installation Information and Instructions

Please ensure that your rootvg contains at least 30 GB and that there is at least 4GB free space before you attempt to update to Update Release 4.1.0.30. Run the lsvg rootvg command, and then ensure there is enough free space.

Example: 

$ lsvg rootvg 



VOLUME GROUP:       
rootvg                   
VG IDENTIFIER:  
00f6004600004c000000014306a3db3d
VG STATE:
active     
PP SIZE:
64 megabyte(s)
VG PERMISSION:            
read/write               
TOTAL PPs:
511 (32704 megabytes)
MAX LVs:                   
256                      
FREE PPs:
64 (4096 megabytes)
LVs:                       
14                       
USED PPs:
447 (28608 megabytes)
OPEN LVs:                    
12 
QUORUM:
2 (Enabled)
TOTAL PVs:                                  
1
VG DESCRIPTORS:
2
STALE PVs:                                  
0
STALE PPs: 
0
ACTIVE PVs:                                         
1
AUTO ON:
yes
MAX PPs per VG:     
32512                                     


MAX PPs per PV:     
1016 
MAX PVs:
32
LTG size (Dynamic):                
256 kilobyte(s)
AUTO SYNC:
no
HOT SPARE:                
no                       
BB POLICY:
relocatable
PV RESTRICTION:     
none                     
INFINITE RETRY:
no

VIOS upgrades with Third Party Software

When the user upgrades from 3.1.x.y to 4.1.0.00 level and above, third-party software is not packaged with the IBM supplied mksysb image. User needs to install the respective third-party software after the upgrade is complete and run viosupgrade -o rerun to restore the respective devices.

Updating from VIOS version 4.1.0.00

VIOS Update Release 4.1.0.30 may be applied directly to any VIOS at level 4.1.0.00.

Before installing the VIOS Update Release 4.1.0.30

Warning: The update may fail if there is a loaded media repository.

Instructions: Checking for a loaded media repository

To check for a loaded media repository, and then unload it, follow these steps.

  1. To check for loaded images, run the following command:

lsvopt 
The Media column lists any loaded media.

  1. To unload media images, run the following commands on all Virtual Target Devices that have loaded images.

unloadopt -vtd <file-backed_virtual_optical_device >

  1. To verify that all media are unloaded, run the following command again.

lsvopt 
The command output should show No Media for all VTDs.


 

Instructions: Migrate Shared Storage Pool Configuration

The Virtual I/O Server (VIOS) Version 3.1.x.y or later, supports rolling updates to release 4.1.0.30 for SSP clusters.

The rolling updates enhancement allows the user to apply Update Release 4.1.0.30 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.

To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:

  • All VIOS logical partitions must have VIOS Update Release version 3.1.x.y  or later installed.
  • All VIOS logical partitions must be running. If any VIOS logical partition in the cluster is not running, the cluster cannot be upgraded to use the new SSP capabilities.
     

Instructions: Verify the cluster is running at the same level as your node.

  1. Run the following command:
    $ cluster -status -verbose
  2. Check the Node Upgrade Status field, and you should see one of the following terms:


UP_LEVEL: This means that the software level of the logical partition is higher than the software level the cluster is running at.

ON_LEVEL: This means the software level of the logical partition and the cluster are the same.

Installing the Update Release

There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link.

Instructions: Verifying VIOS update files.

To verify the VIOS update files, follow these steps:

  1. oem_setup_env
  2. Create a link to openssl if required
    ln -s /usr/bin/openssl /usr/ios/utils/openssl 
  3. Verify the link to openssl was created 
    ls -alL /usr/bin/openssl /usr/ios/utils/openssl 
  4. Verify that both files display similar owner and size 
  5. exit

Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.

If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.

Note: While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.

Warning:  If VIOS rules have been deployed.


During update, there have been occasional issues with VIOS Rules files getting overwritten and/or system settings getting reset to their default values.

To ensure that this doesn’t affect you, we recommend making a backup of the current rules file.  This file is located here:

/home/padmin/rules/vios_current_rules.xml


First, to capture your current system settings, run this command:

$
rules -o capture

Then, either copy the file to a backup location, or save off a list of your current rules:

Note: The "padmin" user is restricted to redirect command output to a file, you must be in the root shell. Use "oem_setup_env" to become a root user.

 

oem_setup_env

# rules -o list > rules_list.txt

After this is complete, proceed to update as normal.  When your update is complete, check your current rules and ensure that they still match what is desired.  If not, either overwrite the original rules file with your backup, or proceed to use the ‘rules -o modify’ and/or ‘rules -o add’ commands to change the rules to match what is in your backup file.

Finally, if you’ve failed to back up your rules, and are not sure what the rules should be, you can deploy the recommended VIOS rules by using the following command:
 

$ rules -o deploy -d

Then, if you wish to copy these new VIOS recommended rules to your current rules file, just run:

$ rules -o capture

Note: This will overwrite any customized rules in the current rules file.
 

Applying Updates

Warning:

If the target node to be updated is part of a redundant VIOS pair, the VIOS partner node must be fully operational before beginning to update the target node.

Note:

For VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.

Warning:

Update to VIOS 4.1.0.30 will update ios.database.rte fileset which might throw below errors, and they can be ignored:

        3001-408  The user "vpgadmin" has an invalid lastupdate attribute.

Instructions: Applying updates to a VIOS.

  1. Log in to the VIOS as the user padmin.
  2. If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.
  3. If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.

    $
     clstartstop -stop -n <cluster_name > -m <hostname >

     
  4. To apply updates from a directory on your local hard disk, follow the steps:
    1. Create a directory on the Virtual I/O Server.
      $
       mkdir <directory_name >
    2. Using ftp, transfer the update file(s) to the directory you created.

      To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:
      1. Mount the remote directory onto the Virtual I/O Server:
        $
         mount remote_machine_name:directory /mnt

         

The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, follow the steps:

      1. Place the CD-ROM into the drive assigned to VIOS.
         
  1. Commit previous updates by running the updateios command:
    $
     updateios -commit

     
  2. Verify the updates files that were copied. This step can only be performed if the link to openssl was created.
    cp <directory_path >/ck_sum.bff /home/padmin 
    chmod 755 </home/padmin>/ck_sum.bff 
    ck_sum.bff <directory_path > 
    If there are missing updates or incomplete downloads, an error message is displayed.

    To see how to create a link to openssl, click
    here.

     
  3. Apply the update by running the updateios command
    $
     updateios -accept -install -dev <directory_name >

     
  4. To load all changes, reboot the VIOS as user padmin .

$ shutdown -restart

Note: If shutdown –restart command failed, run swrole –PAdmin for padmin to set authorization and establish access to the shutdown command properly.

  1. If cluster services were stopped in step 3, restart cluster services.

clstartstop -start -n <cluster_name > -m <hostname >
 

  1. Verify that the update was successful by checking the results of the updateios command and by running the ioslevel command, which should indicate that the ioslevel is now 4.1.0.30.

ioslevel
 

Post-installation Information and Instructions

Instructions: Checking for an incomplete installation caused by a loaded media repository.

After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.

Check the Media Repository by running this command: 
lsrep

If the command reports: "Unable to retrieve repository data due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.

Running the lsvopt command should show the media images.

Instructions: Recovering from an incomplete installation caused by a loaded media repository.

To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:

  1. Unload any media images

unloadopt -vtd <file-backed_virtual_optical_device>

  1. Reinstall the ios.cli.rte fileset by running the following commands.

To escape the restricted shell: 
oem_setup_env 
To install the failed fileset: 
installp –Or –agX ios.cli.rte –d <device/directory > 
 To return to the restricted shell: 
exit

  1. Restart the VIOS.

shutdown –restart

  1. Verify that the Media Repository is operational by running this command:

lsrep

Content modified in this release

ioscli snap command

The snap command is enhanced with -gzip option to utilise the on-chip NX GZIP accelerator for faster completion.

Software Updated

- python3 is included in VIOS image.

- Two versions of postgres database (version 15.3 and 13.11) are included in base image. Postgres version 13 is required to support mixed mode cluster where node versions 3.1.4.x and 4.1.0.x are part of the cluster.

Content removed in this release

ITM Agents software

        ITM (IBM Tivoli Monitoring) filesets are not part of VIOS 4.1.0.00 & above versions. Users need to download and install the ITM software from an external location. The ITM VIOS Premium Agent and ITM CEC Base Agent can be downloaded and installed separately as part of an updated IBM Tivoli Monitoring System P Agents 6.22 Fix Pack 4 or later bundle. Here is a link to the readme file containing information about how to obtain the image and instructions for installing.  When these agents are installed in the default directory of /opt/IBM/ITM, they can continue to utilize the cfgsvc, startsvc, and stopsvc commands to configure, start and stop the agent.

AMS

        Active Memory Sharing (AMS) feature is removed.

Software Removed

        Following filesets that are deemed not necessary are removed.

  • bos.net.tcp.rcmd, bos.net.tcp.rcmd_server (A copy is saved under: /usr/sys/inst.images/installp/ppc)
  • cas.agent tivoli.tivguid
  • rsct.opt.fence.blade rsct.opt.fence.hmc
  • sysmgt.cim.providers.metrics sysmgt.cim.providers.osbase
  • sysmgt.cim.providers.scc sysmgt.cim.providers.smash
  • sysmgt.cim.smisproviders.hba_hdr sysmgt.cim.smisproviders.hhr
  • sysmgt.cim.smisproviders.vblksrv sysmgt.cimserver.pegasus.rte
  • Java7.jre Java7.sdk Java7_64.jre Java7_64.sdk
  • itm.cec.agent itm.premium.rte itm.vios_premium.agent
  • bos.net.nfs.server devices.vdevice.IBM.vfc-client.rte
  • X11.adt.ext X11.adt.motif X11.apps.clients X11.apps.config X11.apps.custom X11.apps.msmit X11.apps.xdm
  • X11.apps.xterm X11.base.xpconfig X11.compat.adt.Motif12 X11.compat.lib.Motif10 X11.compat.lib.Motif114
  • X11.compat.lib.X11R3 X11.compat.lib.X11R4 X11.Dt.bitmaps X11.Dt.helpinfo X11.Dt.helpmin X11.Dt.helprun
  • X11.Dt.lib X11.Dt.rte X11.Dt.ToolTalk X11.fnt.coreX X11.fnt.deform_JP X11.fnt.fontServer X11.fnt.Gr_Cyr_T1
  • X11.fnt.ibm1046 X11.fnt.ibm1046_T1 X11.fnt.iso1 X11.fnt.iso2 X11.fnt.iso3 X11.fnt.iso4 X11.fnt.iso5
  • X11.fnt.iso7 X11.fnt.iso8 X11.fnt.iso8_T1 X11.fnt.iso9 X11.fnt.iso_T1 X11.fnt.ksc5601.ttf X11.fnt.ucs.cjk
  • X11.fnt.ucs.com X11.fnt.ucs.ttf_CN X11.fnt.ucs.ttf_extb X11.fnt.util X11.loc.en_US.base.lib
  • X11.loc.en_US.base.rte X11.loc.en_US.Dt.rte X11.vsm.lib

Fixes included in this release

The list of fixes in 4.1.0.30

APAR

Description

IJ41832

Install images for ICU4C.adt

IJ49571

DUMPCHECK PRINTS UNKNOWN LOCALE

IJ49803

OD MAY OUTPUT HEXADECIMAL VALUE IN REVERSE

IJ50829

JAVA 21: PROBLEM EXTRACTING FILES FROM JAR/ZIP WITH NX/GZIP

IJ51070

MKDVD MAY CHANGE THE TIMESTAMP OF FILES

IJ51164

ID / SU COMMANDS AND LOGIN SLOW FOR LDAP USER

IJ51218

POTENTIAL CRASH IN NFS OR LFS WHEN ERROR REPORTED BY NFS

IJ51278

INSTALLP MISSING OUTPUT FOR SIGNATURE VERIFICATION

IJ51336

MANAGE_DISK_DRIVERS -L STILL DISPLAYS AIX_APPCM IN AIX 7.3

IJ51412

GCC ISSUE CHECK FOR BINDER CHANGES

IJ51458

ASO CORE DUMPS AFTER UPDATING THE AIX  TO 7.3 TL02

IJ51462

SEASTAT: INVALID VALUE REPORTED WITH OPTION -F OR -F

IJ51535

IO HANG WHEN TARGET SUPPORT TAGET RESET

IJ51536

YNew SMS function NVMe SED Password not working

IJ51538

Observing core dump while configuring VFC Host.

IJ51539

Few disks in encrypted when drive is locked

IJ51540

During LPM,START_TARGET_PORT failed for NVME target port.

IJ51541

NPIV disks are not visible on LPAR

IJ51543

J2 FILE REMOVAL OVER NFS CAN RESULT IN A CRASH

IJ51544

Group LPM operation failed with error

IJ51545

PTHREAD_KILL() IS NOT ASYNC-SIGNAL-SAFE RESULTING IN APP HANG

IJ51546

INCREASE SECLDAPCLNTD BASE DN LIMIT

IJ51547

LIVE UPDATE LEADS TO VG QUORUM LOSS AND FILESYSTEM INCONSISTENCY

IJ51548

Timezone data update for latest IANA version 2024a

IJ51549

aio_qlock and pio_qlock locks of aio to be 128 byte cache align

IJ51550

verify_packages fails to verify rpm signature usng -R

IJ51552

OUTPUT OF "TRUSS -TKFCNTL <PID>" SHOIWNG 14

IJ51553

SAVEVG -IR FAILS WHEN A FILESYSTEM IS FULL IN THE VOLUME GROUP

IJ51554

MEMORY LEAK BY POOLFS CAN CAUSE VIOS SERVER RUN OUT OF MEMORY

IJ51555

mksysb_iso msg differ between default and catalog messages

IJ51557

CAA ndd_recv may pass null pointer

IJ51558

nimadm cmd doesn't exit gracefully if "/var" FS is full

IJ51560

VIOSBR ON SSP FAILS WITH ERROR "FAILED SENDING COMMAND TO NODE"

IJ51563

mkvg -k is failing from version 7.2.5.0 if running from client

IJ51566

NIMADM MAY FAIL WITH REACHED USER FILE SIZE LIMIT APPLIES

IJ51649

MKKRB5CLNT GIVES MISLEADING ERROR

IJ51654

UNMIRRORING PASSIVE MWC LV CAN LEAVE DIRTY BIT SET ON DISK

IJ51690

LDAP KRB5 BIND WILL FAIL WITH UTF8 TRANSLATION ENABLED

IJ51727

system crash @empty_bucket during during dr cpu add/remove

IJ51760

RULESCFGSET COMMAND FAILS AFTER VIOS UPDATE

IJ51761

ofed, Avoid using get_en_softc() instead of ifunit()

IJ51763

Error while updating vios4.1.0.20 -> 4.1.0.21

IJ51766

VIOSUPGRADE FAILS WITH SPECIAL CHARACTERS IN CRONTAB

IJ51768

In SSP environment, cluster add node may hang.

IJ51773

EFS KEYS FAIL TO LOAD WHEN LOT OF USERS CONNECT AT THE SAME TIME

IJ51799

vios got crashed due to memory leakage@kthread_sta

IJ51806

SNAP -R IN AIX 7.3 OR VIOS 4.1.X DOES NOT CLEAR SNAP.PAX.GZ

IJ51811

WRONG INPUTS TO CHFS COMMAND CAN MESS UP /ETC/FILESYSTEMS

IJ51842

Some 10GbE/40GbE RoCE adapters do not configure on recent SPs

IJ51878

System Crash during DR when the number of page mappings is > 256

IJ52014

snmpinfo -m dump -v hrProcessorLoad sometime gives wrong output

IJ52024

viosupgrade tool is failing while user created LV on root

IJ52026

Unable to unload OFED in RoCEv2 mode after rping was done to unknown IP

IJ52027

ISCSI I/O HUNG WHEN TASK CMDS ARE LOST

IJ52028

Error was Observed in trustchk_log post 2415B_73F WB

IJ52029

npiv client hang with 2005 reference code in HMC after lpm run.

IJ52030

VIOS got crashed with stack abend_trap->npiv_channel

IJ52032

viosbr -dr cluster restore is failing on 73F node.

IJ52058

LACP ERRLOG MESSAGES ARE MISSING THE PORT INFORMATION

IJ52059

Probable data corruption for data under run case

IJ52060

VIOS got crashed with stack abend_trap

IJ52061

VIOS may crash in npiv stack

IJ52062

Crash while collecting netstats info

IJ52067

POST_VGSYNC REPORTS ERROR MESSAGES DURING MKSYSB RESTORATION

IJ52126

ABEND IN TIMER INTERRUPT DUE TO VLANDD LINK WATCHDOG TIMER

IJ52127

system traces format incorrectly

IJ52128

entstat's ouput "Device Type" looks to be wrong for Austin

IJ52129

Probable fcstat hang during certain error conditions.

IJ52130

I/O fails after few iterations of EEH in single FC adapter case

IJ52133

lscfg and lsmcode commands doesn't show info for Bolt

IJ52134

smitty topas may cause topasout coredump for List recordings.

IJ52140

VNOP_GETATTR_FLAGS MIGHT PASS BAD VA_MASK TO PFS

IJ52260

LPPCHK -F GIVES INCORRECT OUTPUT FOR LARGE SIZED FILES

IJ52273

fix memory leak in CFG_INIT failure path

IJ52274

FOC73F:FVTR-DEV:vio_daemon core dump on DBN node

IJ52275

SVT_VMR_HADRHA: VM_CLEANUP_ON_HMC_SUCCESS event logged thrice

IJ52276

Probable I/O hang when Quick I/O failover feature is enabled

IJ52277

Probable rmdev hang after microcode download

IJ52278

Probable system crash during certain error conditions.

IJ52280

MALFORMED LDAP NETGROUP TRIPLE CAUSES USERS TO NOT BE FOUND

IJ52282

Observed coredump during filemon bucket exec

IJ52283

lport value needs to be displayed for closed connection.

IJ52284

System crash in in_rtchange()

IJ52286

system crash in devcopen when running lvmstat

IJ52288

viosupgrade failed while we are using 4.1.0.10 mksyb imag

IJ52289

A potential security issue exists

IJ52290

Lack of pragma in .msg.S files causes problems for translation

IJ52291

NIM MKSYSB RESTORE HANG IF A VERY LONG LANG VALUE IN IMAGE.DATA

IJ52320

LOCAL MKGROUP FAILING IF LDAP GROUP EXISTS WITH SAME GID NUMBER

IJ52357

MANY HDISK CONFIG 4.1 UPGRADE HAS VIOSBR RESTORE MEM ALLOC FAIL

IJ52399

WHEN LANG SET TO FR_FR MKCD FAILS WITH 0403-057 SYNTAX ERROR

IJ52411

VIOSBR WRONGLY BACKUP HOSTNAME TO IP CONFIGURED IF NOT IN HOSTS

IJ52412

NFSV4 FILE CREATE HANGS DUE TO /ETC/NFS/SECURITY_DEFAULT

IJ52413

dkeyexch cmd hangs in NIM Master

IJ52414

rules command after fresh install leaves algorithm wrong

IJ52415

A potential security issue exists

IJ52416

A potential security issue exists

IJ52417

A potential security issue exists

IJ52418

System crash or hang when ipsec and dog threads are enabled

IJ52420

A potential security issue exists

IJ52421

A potential security issue exists

IJ52422

Correct SSL code logic and add error handling

IJ52423

pmsvcs consumes more pinned memory

IJ52424

VIOS SERVER WITH HIGH NUMBER OF VNIC/ROCE ADAPTERS WON'T BOOT

IJ52425

VIOS DR LIBRARY SUPPORT FOR EMC 8500

IJ52426

Diag menu's FFC001 and FFC002 are not displayed properly

IJ52427

Support for Future TL/SP

IJ52429

Probable I/O hang during FC link failure error recovery

IJ52430

VIO_HS_ADD_VIOS returning VIO_HS_STOP_VM response

IJ52431

SVC firmware update may cause LPAR hang and IO failure.

IJ52432

WITH SYNCVG THROTTLING A CRASH IN VALIDATE_REQ CAN OCCUR

IJ52433

gencopy errors seen in "nim" update cmd

IJ52435

CRASH DURING REBOOT

IJ52522

Performance impact with nonblocking UDP socket (EWOULDBLOCK)

IJ52604

A potential security issue exists

IJ52605

A potential security issue exists

IJ52606

A potential security issue exists

IJ52607

A potential security issue exists

IJ52608

A potential security issue exists

IJ52609

A potential security issue exists

IJ52610

Memory leak in syscall ptx_readinst when called by non-root user

IJ52611

 Password change prompt appears post viosupgrade

IJ52612

Viosupgrade unable to backup rootvg user-defined JFS filesystem

IJ52614

ISST:AUS:rinsev1: Random value "159" in viosupgrade outpu

IJ52689

EMGR FAILS WITH AWK ERROR IF TRADEMARK SIGN IN A FILESET'S DESC

IJ52691

nvmehealth shows error: invalid option --o

IJ52785

ALTERNATE ROOTVG OPERATIONS FAILS IN TRUSTED ENVIRONMENT

IJ52786

AUTHENTICATION WITH EFS LEAK WHEN KEYSTORE DOESN'T EXIST

IJ52787

ISST:BLK:System not booting up and hung at 0555 LED code :

IJ52788

AUTHENTICATE() MIGHT RETURN ENOENT INSTEAD OF ENOMEM

IJ52789

LOCKING ISSUE IN VIRTUAL ADAPTER DRIVER CAUSES COMMAND AND PARTI

IJ52790

GETCONF DISKSIZE RETURNS INCORRECT LUN SIZE FOR FC-NVME DISKS

IJ52791

VNICSTAT NOT WORKING FOR PADMIN AFTER UPDATE

IJ52792

System may crash during FC-NVMe protocol driver configuration.

IJ52793

correcting DD_ENTRY_BSTART trace entry

IJ52797

RENAMED LV IN IMAGE.DATA IS NOT UPDATED AFTER ALT_DISK_COPY.

IJ52798

A potential security issue exists

IJ52811

 trustchk coredump with Ptools bucket exec

IJ52814

Updating timezone data files to latest 2024b database

IJ52955

vmstat output fi/fo seems incorrect when system is in a paging

IJ52958

 VIOS/AIX boot may hang during Broadcom FC HBA config

IJ52960

HST 1060.20 SP: Inactive LPM is failing for NPIV lpar with HSC

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPHKW","label":"PowerVM Virtual I\/O Server"},"Component":"","Platform":[{"code":"PF002","label":"AIX"}],"Version":"All Versions","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}}]

Document Information

Modified date:
03 February 2025

UID

ibm17182400