Troubleshooting
Problem
This technote explains what the error, Version data file had the wrong length (expected: #, found #), means as it relates to the cleartext container of an IBM® Rational® ClearCase MultiSite® VOB during synchronization and provides instructions to resolve the issue.
Symptom
Note:
As of ClearCase releases (Fixpacks) 7.0.0.2 and 7.0.1.1 and later, the condition described in this technote has been downgraded from an Error to a Warning. On export a packet will be generated. A packet generated with a Warning at a 7.0.0.2/7.0.1.1 or later exporter will still cause an error on import at a VOB server that is running an earlier fix level.
Refer to APAR PK53268 for further details about this change. IBM Rational advises that these warning messages should be addressed as described below. The behavior change is so that critical synchronization is not delayed.
The following excerpt is a complete look at the error generated during synchronization:
%> multitool syncreplica -export -fship original
Generating synchronization packet
/opt/rational/clearcase/shipping/ms_ship/outgoing/sync_packet
multitool: Error: multitool: Error: Version data file
/host1/projects/vobstore/test.vbs/c/cdft/18/3f/
d6b713d534ff11da91a800306e4b3826 had the wrong length (expected:605152, found: 605097).
multitool: Error: multitool: Error: Please contact IBM Rational
Customer Support for assistance.
multitool: Error: multitool: Error: Could not get statistics of the version data file for this operation.
503442:
op= checkin
replica_oid= e2190341.75f711d9.909b.00:30:6e:13:76:cd
oplog_id= 284353
op_time= 04-Oct-05.17:56:43UTC create_time= 04-Oct-05.17:56:43UTC
version_oid= d6b713d5.34ff11da.91a8.00:30:6e:4b:38:26
event comment= ""
data size= 108 data= 0x40084b60
ckout_ver_oid= 379b0970.350111da.8a59.00:11:43:07:44:eb
multitool: Error: multitool: Error: Removing incomplete packet
/opt/rational/clearcase/shipping/ms_ship/outgoing/sync_packet
multitool: Error: Could not complete synchronization request: error detected by ClearCase subsystem.
Note: This error has a positive number or zero for the found value and references the cleartext container (c/cdft) as the directory.
- If the reference is to a source container (s/sdft) and the value of the found section is a positive number refer to technote 1221903.
- If the reference is to a source container (s/sdft) and the value of the found section is zero refer to technote 1221902.
Log InLog in to view more of this document
Was this topic helpful?
Document Information
Modified date:
29 September 2018
UID
swg21221901