This technote explains what the error, Version data file had the wrong length expected: #, found 0, means as it relates to the source container of an IBM® Rational® ClearCase MultiSite® VOB during synchronization and provides instructions to resolve the issue.

Symptom


The following excerpt is a complete look at the error generated during synchronization:

%> multitool syncreplica -export -fship original
Generating synchronization packet
/opt/rational/clearcase/shipping/

ms_ship/outgoing/sync_packet

multitool: Error: multitool: Error: Version data file
/host1/projects/vobstore/test.vbs/
s/sdft/18/3f/
d6b713d534ff11da91a800306e4b3826 had the wrong length (
expected:605152, found: 0).

multitool: Error: multitool: Error: Please contact IBM Rational
Customer Support for assistance.
multitool: Error: multitool: Error: Could not get statistics of the version data file for this operation.
503442:
op= checkin
replica_oid = e2190341.75f711d9.909b.00:30:6e:13:76:cd
oplog_id= 284353
op_time= 04-Oct-05.17:56:43UTC  create_time= 04-Oct-05.17:56:43UTC
version_oid=
d6b713d5.34ff11da.91a8.00:30:6e:4b:38:26
event comment= ""
data size= 108  data= 0x40084b60
ckout_ver_oid= 379b0970.350111da.8a59.00:11:43:07:44:eb
multitool: Error: multitool: Error: Removing incomplete packet
/opt/rational/clearcase/shipping/ms_ship/outgoing/sync_packet
multitool: Error: Could not complete synchronization request: error detected by ClearCase subsystem.



Note: This error has a zero for the found value and references the source container (s/sdft) as the directory.

  • If the reference is to a source container (s/sdft) and the value of the found section is a positive number refer to technote 1221903.

  • If the reference is to a cleartext container (c/cdft) and the value of the found section is a positive number or zero refer to technote 1221901.

[{"Product":{"code":"SSSH27","label":"Rational ClearCase"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":"Synchronization","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"2002.05.00;2003.06.00;7.0","Edition":"","Line of Business":{"code":"LOB77","label":"Automation Platform"}},{"Product":{"code":"SSSH27","label":"Rational ClearCase"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":"Multitool","Platform":[{"code":"","label":""}],"Version":"","Edition":"","Line of Business":{"code":"LOB77","label":"Automation Platform"}}]