IBM Support

Upgrade ZVM720, Subset CP

Preventive Service Planning


Abstract

z/VM - CP Version 7, Release 2, Modification 0

Content

  Preventive Service Planning

PSP Upgrade ZVM720, Subset CP

Upgrade ZVM720, Subset CP

Service Recommendation Summary Installation Information
Documentation Changes General Information
Service Recommendations Cross Product Dependencies
Informational/Documentation PTF/APAR Reference Lists


Upgrade ZVM720, Subset CP:

This subset contains installation information for z/VM - CP
Version 7, Release 2, Modification 0.


Change Summary

DATE LAST CHANGED SECTION 1. 22/03/23 INSTALLATION INFORMATION 2. 22/03/23 DOCUMENTATION CHANGES 3. YY/MM/DD GENERAL INFORMATION NO ENTRIES 4. 22/05/17 SERVICE RECOMMENDATIONS SEE 2301RSU 5. YY/MM/DD CROSS PRODUCT DEPENDENCIES NO ENTRIES


Service Recommendation Summary

DATE APAR PTF VOLID COMMENTS 1. YY/MM/DD XXXXXXX XXXXXXX XXXX XXX


Installation Information

This section contains changes to the product's Program Directory. and additional information which should be review before installing the product. Please note the additional APARs required for older z/VM releases when they are members of a mixed environment SSI cluster. 7. 22/03/23 UPGRADE INSTALL: INSTALL VMSES APAR BEFORE UPGRADING Before upgrading from z/VM 7.1 to 7.2 you should install and put into production the PTF for APAR VM66519 (UM35857). This PTF was included on RSU 7105 (CP Service level 2101). When this PTF is installed you should not need to perform the actions outlined in item 1 below. There is no PTF for z/VM 6.4 so you will need to perform the actions in item 1 when upgrading to z/VM 7.2. After upgrading to 7.2 you should install the 7.2 PTF for APAR VM66519 (UM35858). This PTF was included on z/VM 7.2 RSU 7203 (CP Service level 2102). 6. 21/07/21 Warning message during INSTUPGR STAGE2 (PRIME to ignore If you use RACF and GCS on your system you may have copied two RACF files, RPICDX LOADLIB and RPIGCS LOADLIB, to the MAINT 193 minidisk. If you did, you might receive this warning message when you run INSTUPGR STAGE2 (PRIME: * The following files found on your MAINT 193 minidisk * were not listed in the VM PARTCAT for prodid 7VMRAC10%RACF, * but will be overwritten during COMMIT processing. RPICDX LOADLIB RPIGCS LOADLIB You should ignore this message. 5. 21/02/17 Restricted device address for installation When installing z/VM (any release, traditional or upgrade) do not use device address 0000 for any of your installation volume address. This address will result in an error when loading the new release code to the installation volumes. 4. 21/01/26 Upgrade Install: Apply RACF-related APARs to DirMaint If you are using RACF/VM and DirMaint on your system and DirMaint is enabled to communicate with RACF (USE_RACF= YES), before you begin your upgrade to z/VM 7.2.0, it is recommended that you install the PTF for DirMaint APAR VM66044 on your z/VM 6.4.0 or 7.1.0 system. The PTF numbers are: APAR PTF VM66044 UV99364 for z/VM 6.4.0 UV99365 for z/VM 7.1.0 If you also have ESM logging enabled for DirMaint (ESM_LOG_RECORDING_EXIT= DVHESMLR EXEC), it is recommended that you install the PTF for DirMaint APAR VM66204: APAR PTF VM66204 UV99374 for z/VM 6.4.0 UV99376 for z/VM 7.1.0 After you have completed your upgrade it is recommended that you install the PTF for DirMaint APAR VM66204 for z/VM 7.2.0 (PTF UV99376) on your z/VM 7.2.0 system. 3. 21/01/26 Upgrade Install and RACF/VM: Verify MAINT720 minidisk access If you are using RACF/VM and DirMaint on your system and DirMaint is enabled to communicate with RACF (USE_RACF= YES) and if you are using or did use the upgrade installation procedure to move to z/VM V7 R2, before attempting to install any additional service, you should verify that MAINT720 is not restricted to READ access for any of the MAINT production minidisks. When the MAINT720 userid is added to your system the directory entry contains read links to the following minidisks: MAINT 190 MAINT 193 MAINT 19E MAINT 19D MAINT 402 DirMaint will instruct RACF to update the RACF profiles for those minidisks and add MAINT720 with READ authority. For security, this is working as designed. However, MAINT720 must be able to link to all production minidisks using link mode MR. You will need to either remove the specific READ authority (so that the OPERATIONS authority that MAINT720 should have will be in effect) or change the specific authority to CONTROL (so that MAINT720 can link to the disks with link mode MR.) 2. 21/01/26 Maximum size for installing z/VM on SCSI volumes For z/VM V7 R2 and prior releases, the maximum volume size for installing on SCSI volumes is 400GB. 1. 21/01/26 Upgrade Install and DirMaint: Need to purge reader files If you are using the upgrade installation procedures and you use DirMaint, before beginning Stage 2 of the upgrade process, ensure that no extraneous reader files exist in the virtual reader for the following user IDs: BLDNNUC BLDCMS BLDSEG BLDRACF To verify that the virtual readers are clean, please log on to each user ID and do the following: Issue the command: QUERY FILES You should see the message: FILES: NO RDR, NO PRT, NO PUN Ready; ... If any reader files are cited, enter the command: PURGE * RDR ALL Log off the user ID.


Documentation Changes

This section outlines major errors in the product's published documentation. 2. 22/03/23 Correction to"z/VM 7.2.0 Installation Guide": In Chapter 17 "Finish the STAGE1 upgrade", Step 3 (page 178), change substep 6 to the following: 6. If certain local modifications exist against RACF, RACF objects need to be rebuilt. a. If a local modification exists against RACF part ICHRDSNT ASSEMBLE which changes the name of the primary and/or backup RACF dataset, the following commands must be run to rebuild the objects built from the updated ICHRDSNT part: VMFSETUP SERVP2P RACF VMFBLD PPF SERVP2P RACF RPIBL505 ICHRDSNT (ALL VMFBLD PPF SERVP2P RACF RPIBLLNK ICHRDSNT (ALL b. Certain RACF exits do not appear as local modifications, but they need to be rebuilt before continuing. - If no TXT00000 files exist on the RACF local modification disk (7VMRAC20 2C2 or VMPSFS:7VMRAC20.RACF.SAMPLE), skip to substep 7 on page 178. - If TXT00000 files do exist on the RACF local modification disk (7VMRAC20 2C2 or VMPSFS:7VMRAC20.RACF.SAMPLE), perform a RACF build: VMFSETUP SERVP2P RACF VMFBLD PPF SERVP2P RACF RPIBLLPA (ALL 1. 21/07/14 Corrections for "z/VM 720: Installation Guide" The corrections are as follows: - In Chapter 2, Step 3, Substep 9: all mention of 3390 volume size 11000 cylinders should be 11500 cylinders - In Chapter 2, Step 3, substep 10: all mention of FBA volume size 8.0 GB should be 8.5 GB - In Chapter 12, Step 3, substep 4: all mention of FBA volume size of 8.0 GB should be 8.5 GB - In Chapter 12, Step 3, substep 4: all mention of 3390 volume size 11000 cylinders should be 11500 cylinders - In Chapter 12, Step 7, substep 1: all mention of 3390 volume size 11000 cylinders should be 11500 cylinders - In Chapter 12, Step 8, substep 1: all mention of FBA volume size of 8.0 GB should be 8.5 GB NO ENTRIES 1. 21/07/20 Corrections for "z/VM 720: Installation Guide" The corrections are as follows: - In Chapter 2, Step 3, Substep 9: all mention of 3390 volume size 11000 cylinders should be 11500 cylinders - In Chapter 2, Step 3, substep 10: all mention of FBA volume size 8.0 GB should be 8.5 GB - In Chapter 12, Step 3, substep 4: all mention of FBA volume size of 8.0 GB should be 8.5 GB - In Chapter 12, Step 3, substep 4: all mention of 3390 volume size 11000 cylinders should be 11500 cylinders - In Chapter 12, Step 7, substep 1: all mention of 3390 volume size 11000 cylinders should be 11500 cylinders - In Chapter 12, Step 8, substep 1: all mention of FBA volume size of 8.0 GB should be 8.5 GB


General Information

This section contains general information, i.e. SYSGEN hints/tips. 1. YY/MM/DD NO ENTRIES


Service Recommendations

1. 22/05/17 REFER TO 2301RSU


Cross Product Dependencies

This section contains information that is dependent upon another product other than this subset ID. It also contains information dealing with migration and product coexistance. 1. YY/MM/DD INTERDEPENDENT PRODUCT: PROBLEM: USERS AFFECTED: RECOMMENDATION: INSTALL XXXXXXX ON VOLID XXXX


Informational / Documentation


PTF / APAR Reference Lists

PTF Include List
PTF Exclude List
PE APAR List


End of Upgrade ZVM720, Subset CP, as of 2023/06/27.


[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG90","label":"zOS- OS 390- MVS"},"Platform":[{"code":"PF054","label":"z Systems"}],"Line of Business":{"code":"LOB56","label":"Z HW"}}]

Document Information

Modified date:
27 June 2023

UID

isg1_ZVM720_CP