Troubleshooting
Problem
This document provides instructions to update the HMC Version 7.7.8 with the latest fixes for 7.7.8.
Resolving The Problem
This document provides instructions for updating HMC Version 7.7.8 with the latest fixes for 7.7.8.
If the HMC is not at 7.7.8, you should first upgrade to 7.7.8 using one of the following documents:
o If the HMC is at an earlier release of Version 7, refer to document N1021593 Upgrading the HMC from Version 7.3.x or Version 7.7.x to Version 7.7.8. To link to document N1021593 immediately, click here
Special Note: Corrective service fix Service Pack 2 for HMC 7.7.8 fixes openssl security vulnerability CVE-2014-0160 and CVE-2014-0076 (Heartbleed" problem). After installing the fix, additional instructions are needed. See Security Bulletin: Power Hardware Management Console is affected by vulnerabilities in OpenSSL (CVE-2014_0160 and CVE-2014-0076) at http://www-01.ibm.com/support/docview.wss?uid=nas8N1020021 This vulnerability was originally addressed by corrective service fix MH01423, which was superseded by MH01447 and is now superseded by SP2. If either MH01423 or MH01447 were installed previously AND the additional instructions followed at that time, it is not necessary to repeat the additional instructions. Otherwise, refer to the link above and follow the instructions provided there after installing SP2.
Readme file for 7.7.8 fixes can be found at the following URLs:
V7R7.8 Mandatory Corrective service fix Service Pack 1: http://delivery04.dhe.ibm.com/sar/CMA/HMA/04czk/1/MH01397.readme.html
V7R7.8 Corrective service fix Service pack 2: http://delivery04.dhe.ibm.com/sar/CMA/HMA/0507y/1/MH01432.readme.html
V7R7.8 Corrective service fix MH01570: http://delivery04.dhe.ibm.com/sar/CMA/HMA/05k1k/1/MH01570.readme.html
If the HMC has not been restarted recently, you should restart before you begin the updates.
Tab navigation
- .iso images - selected tab,
- Ordering / Using DVDs
- Internet
.iso images
| Important information when using .iso images for 7.7.8 corrective service fixes The HMC is now able to read .iso files. This provides additional options for updating from media. Available options are: 1) Burn the iso file as image to CD-R/DVD-R. This is the traditional method used in the past and requires one CD/DVD per fix. 2) Copy one or more iso files to media. The fixes are copied to media as data. The media can be CD-R, DVD-R, or USB. Multiple fixes (iso files) can be placed on the same media if space permits. Do the following to obtain the Version 7.7.8 Required Corrective Service Fixes: Step 1: Download Service Pack 1 HMC_Update_V7R780_SP1.iso Step 2: Download Corrective service fix HMC_Update_V7R780_SP2.iso Step 3: Download Corrective service fix MH01570.iso Step 4: Either burn the .iso file as data to DVD-R, or copy to USB flash drive. Note: Service pack 2 requires that either SP1 OR MH01388 for SP0 be installed first. If either is already installed, continue with installing SP2. If neither is installed, first install SP1 followed by SP2. Repeat Step 1 above using SP2 media. It is mandatory that the HMC be restarted after each update 3. Install the Corrective Service Fix MH01570 Repeat Step 1 above using MH01570 media. It is mandatory that the HMC be restarted after each update 4. If either MH01423 or MH01477 was previously installed and the special instructions in the security bulletin below already completed, this step can be skipped. If MH01423 or MH01477 was NOT previously installed, follow the special instructions for the CVE-2014-0160 "Heartbleed" fix. See Security Bulletin: Power Hardware Management Console is affected by vulnerabilities in OpenSSL (CVE-2014_0160 and CVE-2014-0076) at http://www-01.ibm.com/support/docview.wss?uid=nas8N1020021. |
Ordering / Using DVDs
| To obtain the media for Version 7.7.8 Required Corrective Service Fixes Step 1: Order the 7.7.8 corrective service fixes: MH01397 (SP1) MH01432 (SP2) MH01570 Note: Service pack 2 requires that either SP1 OR MH01388 for SP0 be installed first. If either is already installed, continue with installing SP2. If neither is installed, first install SP1 followed by SP2.
Repeat step 1 above using SP2 media. It is mandatory that the HMC be restarted after each update 3. Install the Corrective Service Fix MH01570 Repeat step 1 above using MH01570 media. It is mandatory that the HMC be restarted after each update 4. If either MH01423 or MH01477 was previously installed and the special instructions in the security bulletin below already completed, this step can be skipped. If MH01423 or MH01477 was NOT previously installed, follow the special instructions for the CVE-2014-0160 "Heartbleed" fix. See Security Bulletin: Power Hardware Management Console is affected by vulnerabilities in OpenSSL (CVE-2014_0160 and CVE-2014-0076) at http://www-01.ibm.com/support/docview.wss?uid=nas8N1020021. |
Internet
To install Version 7.7.8 Required Corrective Service fixes directly from the IBM FTP site, do the following:
Repeat Step 1 with the changes to Steps e and g shown in blue below: e On the Installation and Configuration Options panel: (If using a local FTP server, modify the entries as appropriate for your local FTP server) Remote server type: FTP Remote Server: public.dhe.ibm.com User ID: anonymous Password: g On the Select Service Package panel, scroll down to HMC_Update_V7R780_SP2.iso, click to select, then click Next. The total size of the HMC_Update_V7R780_SP2.iso file is 1.7G. It is mandatory that you restart the HMC after each update. |
3. Install Corrective Service Fix MH01570
Repeat Step 1 with the changes to Steps e and g shown in blue below:
e On the Installation and Configuration Options panel:
(If using a local FTP server, modify the entries as appropriate for your local FTP server)
Remote server type: FTP Remote Server: public.dhe.ibm.com User ID: anonymous Password:Remote directory: /software/server/hmc/fixes
g On the Select Service Package panel, scroll down to MH01570.iso, click to select, then click Next.
The total size of the MH01570.iso file is 1.4G.
It is mandatory that you restart the HMC after each update.
4. If either MH01423 or MH01477 was previously installed and the special instructions in the security bulletin below already completed, this step can be skipped.
If MH01423 or MH01477 was NOT previously installed, follow the special instructions for the CVE-2014-0160 "Heartbleed" fix. See Security Bulletin: Power Hardware Management Console is affected by vulnerabilities in OpenSSL (CVE-2014_0160 and CVE-2014-0076) at http://www-01.ibm.com/support/docview.wss?uid=nas8N1020021.
Verifying a Successful Update
After the HMC was restarted, do the following to verify that the HMC upgrade was successful:
| 1. | Select Welcome from the Navigation panel. |
| 2. | Point your mouse over the HMC Version link on the Content panel to display the Version information. You will see the following: Version: 7 Release: 7.8.0 Service Pack: 2 HMC Build level 20151013.2 MH01570: Fix for security updates (10-13-2015) base_version=V7R7.8.0 |
Backup of HMC Data, and Requirements for Recovery of HMC
It is recommended that you perform a backup of the HMC. Instructions for the HMC backup are provided at the following link:
http://pic.dhe.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/iphai/backingupcriticalconsoledata.htm
Starting with 7.7.8, DVD-RAM is no longer supported for backup and restore of console data.
Historical Number
690069604
Was this topic helpful?
Document Information
Modified date:
22 September 2021
UID
nas8N1021586