IBM Support

Troubleshooting technote

Troubleshooting


Problem

fn_util mlb_mig_sec_cols failed to create new security information column for Index or WorkFlo database.

Symptom

1] Index Database:
2016/12/07 18:32:24.535 <fnsw> dbupgrade -Q -m -r 100017-100027 -k 4(148.1.9 0x94.1) ... [INFO]
Migrating multi-column security columns

2016/12/07 18:32:24.570 121,0,47 HGGCQ0047I <fnsw> dbupgrade -Q -m -r 100017-100027 -k 4 (148.1.9 0x94.1) ... [INFO]
Columns 'f_accessrights_rd', 'f_accessrights_wr', 'f_accessrights_ax' do not exist in table 'document_class'. Please run 'fn_util mlb_add_sec_cols' first.

2016/12/07 18:32:24.571 121,0,47 HGGCQ0047I <fnsw> dbupgrade -Q -m -r 100017-100027 -k 4 (148.1.9 0x94.1) ... [INFO]
Migration ABORTED

Here table is “document class”. Table name can be any of the index tables mentioned in the Table 1.1.

2] WorkFlo Database:
2016/11/05 22:28:45.676 121,0,47 <fnsw> WQS_convert -m (13647.1.15 0x354f.1) ... [SERIOUS]
New security columns (ws_access_rd, ws_access_wr, and ws_access_ax) must exist prior to migration.

2016/11/05 22:28:45.686 0,0,47 <fnsw> fn_util mlb_mig_sec_cols (13607.1.10 0x3527.1) ... [SERIOUS]
fn_util: 'WQS_convert -m' FAILED. Command is aborted.

[{"Product":{"code":"SSNVUD","label":"FileNet Image Services"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":"--","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"4.2;4.1.2","Edition":"","Line of Business":{"code":"LOB76","label":"Data Platform"}}]

Log InLog in to view more of this document

This document has the abstract of a technical article that is available to authorized users once you have logged on. Please use Log in button above to access the full document. After log in, if you do not have the right authorization for this document, there will be instructions on what to do next.

Document Information

More support for:
FileNet Image Services

Software version:
4.2, 4.1.2

Operating system(s):
AIX, HP-UX, Solaris, Windows

Document number:
287579

Modified date:
30 April 2025

UID

swg21995828

Manage My Notification Subscriptions