Troubleshooting
Problem
Troubleshooting POST error codes for the IBM BladeCenter HS40
Resolving The Problem
This document is intended for trained servicers who are familiar with IBM server products. Use this manual along with advanced diagnostic tests to troubleshoot problems effectively. Before servicing an IBM product, be sure to review the Safety information.
Note: See System service parts listing - IBM BladeCenter HS40 to determine which components should be replaced by a field service technician.
The following table lists error codes that might be sent to the management module for error logging as BMC pass-through error entries for the management module system-error log (SEL).
Note: The syntax of error logging between the management module and the SEL might be different. Local SEL error codes might differ from the SEL entries logged by the management module for identical event types.
In the following error codes, X can be any number or letter.
|
Error code/Symptom
|
FRU/Action
|
|---|---|
| 0000 (Timer error) |
|
| 0005 (CMOS checksum bad loading defaults) |
Information only; no action required. |
| 0012 (CMOS date/time not set) |
Run the Configuration/Setup Utility program, and set the date and time. |
| 0040 (Refresh timer test failed) |
|
| 0044 (DMA controller error) |
|
| 0045 (DMA-1 error) |
|
| 0046 (DMA-2 error) |
|
| 004C (Keyboard/interface error) |
|
| 004D (Primary master hard disk error) |
|
| 004F (Secondary master hard disk error) |
|
| 0055 (Primary master drive - ATAPI incompatible) |
|
| 0057 (Secondary master drive - ATAPI incompatible) |
|
| 005D (ATA SMART failure error (dynamic string)) |
|
| 196 (Processor cache mismatch detected) |
|
| 198 (Processor speed mismatch detected) |
|
| 289 (Non-matching or missing DIMMs, user has not installed DIMMs correctly, or DIMM disabled by POST or user) |
|
| 8120 (Microprocessor 1 thermal trip error) |
|
| 8121 (Microprocessor 2 thermal trip error) |
|
| 8122 (Microprocessor 3 thermal trip error) |
|
| 8123 (Microprocessor 4 thermal trip error) |
|
| 8130 (Microprocessor 1 disabled) |
|
| 8131 (Microprocessor 2 disabled) |
|
| 8133 (Microprocessor 3 disabled) |
|
| 8134 (Microprocessor 4 disabled) |
|
| 8140 (Microprocessor 1 failed FRB-3 timer) |
|
| 8141 (Microprocessor 2 failed FRB-3 timer) |
|
| 8142 (Microprocessor 3 failed FRB-3 timer) |
|
| 8143 (Microprocessor 4 failed FRB-3 timer) |
|
| 8160 (Microprocessor missing microcode) |
|
| 8180 (BIOS does not support current stepping for microprocessor 1) |
|
| 8192 (L2 Cache size mismatch) |
|
| 8193 (CPUID, Processor Stepping are different) |
|
| 8194 (CPUID, Processor Family are different) |
|
| 8196 (Processor models are different) |
|
| 8197 (CPU Speed mismatch) |
|
| 8300 (Baseboard Management Controller failed to function) |
|
| 8301 (Front Panel Controller failed to function) |
|
| 84F2 (Server management interface failed) |
|
| 84F3 (BMC in update mode) |
|
| 84F4 (Sensor Data Record empty) |
|
| 84FF (System Event Log full) |
Clear the System Event Log. |
| 00150900 (SERR/PERR detected on PCI bus.) |
|
| 00151730 (IMB parity/CRC error) |
|
| Note: The following errors appear on the screen during POST and in the management-module error log. | |
| Microprocessor 1 internal error (IERR) |
|
| Microprocessor 2 internal error (IERR) |
|
| Microprocessor 3 internal error (IERR) |
|
| Microprocessor 4 internal error (IERR) |
|
| Support forums |
| Submit a technical question |
| Before you call IBM Service |
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
29 January 2019
UID
ibm1MIGR-55506