Specifications (PC Server 325 - Type 8639)

Size
With pedestal:
Depth: 473 mm (18.6 in.)
569 mm (22.6 in.) with cable cover
Height: 455 mm (17.9 in.)
Width: 315 mm (12.4 in.)
Without pedestal:
Depth: 473 mm (18.6 in.)
569 mm (22.6 in.) with cable cover
Height: 425 mm (16.7 in.)
Width: 195 mm (7.7 in.)
Drawer model:
Depth: 465 mm (18.3 in.)
Height: 216 mm (8.5 in.)
Width: 482 mm (19.0 in.)

Weight
Typical server as shipped: 17.0 kg (37.5 lb)

Environment
Air temperature:
Server on: 10? to 35? C
(50? to 95? F)
Altitude: 0 to 914 m (3000 ft.)
Server on: 10? to 32? C
(50? to 90? F)
Altitude: 914 m (3000 ft.) to 2133 m (7000 ft.)
Server off: 10? to 43? C
(50? to 110? F)
Maximum Altitude: 2133 m (7000 ft.)
Humidity:
Server on: 8% to 80%
Server off: 8% to 80%
Maximum altitude: 2133 m (7000 ft)

Electrical Input
Sine-wave input (50 to 60 Hz) is required
Input voltage:
Low range:
- Minimum: 90 V ac
- Maximum: 137 V ac
High range:
- Minimum: 180 V ac
- Maximum: 265 V ac
Input kilovolt-amperes (kVA) approximately:
- Minimum configuration as shipped: 0.08 kVA
- Maximum configuration: 0.52 kVA

Total Power Available for Drives
Nominal Operating Current allowed:
+5 V dc line: 5.3 A
+12 V dc line: 5.0 A

Heat Output
Approximate heat output in British Thermal Units (BTU) per hour:
Minimum configuration: 350 BTU (102 watts)
Maximum configuration: 860 BTU (251 watts)

Document Location

Worldwide

Operating System

Older System x:All operating systems listed