Package Information

PACKAGE: Update Release 3.1.1.21
IOSLEVEL: 3.1.1.21

VIOS level is

NIM Master level must be equal to or higher than

Update Release 3.1.1.21

AIX 7200-04-02

 

Please refer to the VIOS Maintenance Strategy here for more details regarding the change to the VIOS release numbering scheme.

 

General package notes

Be sure to heed all minimum space requirements before installing.

Review the list of fixes included in Update Release 3.1.1.21

To take full advantage of all the functions available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 3.1.1.21.

Microcode or system firmware downloads for Power Systems

Update Release 3.1.1.21 updates your VIOS partition to ioslevel 3.1.1.21. To determine if Update Release 3.1.1.21 is already installed, run the following command from the VIOS command line.

$ ioslevel

If Update Release 3.1.1.21 is installed, the command output is 3.1.1.21.

Important Changes in 3.1.X.X for SSP users

A database manager change has occurred for Shared Storage Pool (SSP).  This change will have no direct impacts on behavior, however it does mean that non-disruptive upgrades of an SSP cluster to 3.1.X.X requires that SSP nodes first are updated to version 2.2.6.31 or higher before upgrading to a version of 3.1.0.0 or higher.

 

Once all VIOS nodes in the cluster have been updated to the latest 2.2.6.X version, double check that rolling upgrade has completed.  This can be done by checking the output of “cluster -status -verbose” while logged in as padmin on one of the VIOS nodes in the cluster.  Then, check the output for each node, and check for this field:

 

    Node Upgrade Status:  2.2.6.31 ON_LEVEL

 

If all nodes have 2.2.6.31 or newer, and all say that they are “ON_LEVEL,” then upgrades to the VIOS to 3.1.0.00 or newer can occur without disruption to the SSP cluster.

 

Additionally, backup and restore can be used to restore older versions of the SSP cluster to 3.1.X.X versions of the VIOS.

 

Note: 3.1.X.X nodes are unable to join SSP clusters that contain nodes below level 2.2.6.31 or clusters with exclusively 2.2.6.31 or higher nodes prior to the nodes completing a rolling upgrade and saying that they are ON_LEVEL.

 

Lastly, customers that do not use Shared Storage Pool will be unaffected by this change.

 

Installation Information

Pre-installation Information and Instructions

Please ensure that your rootvg contains at least 30 GB and that there is at least 4GB free space before you attempt to update to Update Release 3.1.1.21. Run the lsvg rootvg command, and then ensure there is enough free space.

Example: 

$ lsvg rootvg 
VOLUME GROUP:       rootvg                   VG IDENTIFIER:  00f6004600004c000000014306a3db3d
VG STATE:           active                   PP SIZE:        64 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      511 (32704 megabytes)
MAX LVs:            256                      FREE PPs:       64 (4096 megabytes)
 
LVs:                14                       USED PPs:       447 (28608 megabytes)
OPEN LVs:           12                       QUORUM:         2 (Enabled)
TOTAL PVs:          1                        VG DESCRIPTORS: 2
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         1                        AUTO ON:        yes
MAX PPs per VG:     32512                                     
MAX PPs per PV:     1016                     MAX PVs:        32
LTG size (Dynamic): 256 kilobyte(s)          AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
PV RESTRICTION:     none                     INFINITE RETRY: no
 
 
Virtual I/O Server support for Power Systems

 

Upgrading from VIOS version 3.1.1.00 and above

 

VIOS Update Release 3.1.1.21 may be applied directly to any VIOS that is at either level 3.1.1.00 or above.

 

Upgrading from VIOS version 3.1.0.00 and above

 

The VIOS must be upgraded to version 3.1.1.00 or 3.1.1.10 before Update Release 3.1.1.21 may be applied.

 

A single-step upgrade can be performed, but it requires that the user does the following:

 

1.     Put the 3.1.1.10 install packages into the desired install directory.

2.     Place the 3.1.1.21 install packages in the same directory.

3.     Use the updateios command to perform the update.

  

Upgrading from VIOS version 2.2.6.X and below

 

The VIOS must first be upgraded to 3.1.0.00 before the 3.1.1.21 update can be applied.  To learn more about how to do that, please read the information provided here. 

 

Before installing the VIOS Update Release 3.1.1.21

 

Warning: The update may fail if there is a loaded media repository.

 

Instructions: Checking for a loaded media repository

 

To check for a loaded media repository, and then unload it, follow these steps.

 

1.     To check for loaded images, run the following command:

$ lsvopt 
The Media column lists any loaded media.

 

2.     To unload media images, run the following commands on all Virtual Target Devices that have loaded images.

$ unloadopt -vtd <file-backed_virtual_optical_device >

 

3.     To verify that all media are unloaded, run the following command again.

$ lsvopt 
The command output should show No Media for all VTDs.

 

Instructions: Migrate Shared Storage Pool Configuration

 

The Virtual I/O Server (VIOS) Version 2.2.2.1 or later, supports rolling updates for SSP clusters. The VIOS can be updated to Update Release 3.1.1.21 using rolling updates.

A non-disruptive rolling update to VIOS 3.1 requires all SSP nodes to be at VIOS 2.2.6.31 or later. See detailed instructions in the VIOS 3.1 documentation.

 

The rolling updates enhancement allows the user to apply Update Release 3.1.1.21 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.

 

To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:

 

·        All VIOS logical partitions must have VIOS Update Release version 2.2.6.31 or later installed.

·        All VIOS logical partitions must be running. If any VIOS logical partition in the cluster is not running, the cluster cannot be upgraded to use the new SSP capabilities.

Instructions: Verify the cluster is running at the same level as your node.

 

1.     Run the following command:
$ cluster -status -verbose

2.     Check the Node Upgrade Status field, and you should see one of the following terms:


UP_LEVEL: This means that the software level of the logical partition is higher than the software level the cluster is running at.

ON_LEVEL: This means the software level of the logical partition and the cluster are the same.

 

Installing the Update Release

 

There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link.

 

Instructions: Verifying VIOS update files.

To verify the VIOS update files, follow these steps:

1.     $ oem_setup_env

2.     Create a link to openssl 
# 
ln -s /usr/bin/openssl /usr/ios/utils/openssl 

3.     Verify the link to openssl was created 
# 
ls -alL /usr/bin/openssl /usr/ios/utils/openssl 

4.     Verify that both files display similar owner and size 

5.     # exit

 

Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.

 

If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.

 

Note: While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.

 

Version Specific Warning: Version 2.2.2.1, 2.2.2.2, 2.2.2.3, or 2.2.3.1

You must run updateios command twice to get bos.alt_disk_install.boot_images fileset update problem fixed.

 

Run the following command after the step of "$ updateios –accept –install –dev <directory_name >" completes.

$ updateios –accept –dev <directory_name >

 

Depending on the VIOS level, one or more of the LPPs below may be reported as "Missing Requisites", and they may be ignored.

MISSING REQUISITES: 

     X11.loc.fr_FR.base.lib 4.3.0.0        # Base Level Fileset
     bos.INed 6.1.6.0                      # Base Level Fileset
     bos.loc.pc.Ja_JP 6.1.0.0              # Base Level Fileset
     bos.loc.utf.EN_US 6.1.0.0             # Base Level Fileset
     bos.mls.rte 6.1.x.x                   # Base Level Fileset

 

Warning:  If VIOS rules have been deployed.


During update, there have been occasional issues with VIOS Rules files getting overwritten and/or system settings getting reset to their default values.

 

To ensure that this doesn’t affect you, we recommend making a backup of the current rules file.  This file is located here:

/home/padmin/rules/vios_current_rules.xml


First, to capture your current system settings, run this command:

$
rules -o capture

 

Then, either copy the file to a backup location, or save off a list of your current rules:

 

$ rules -o list > rules_list.txt

 

After this is complete, proceed to update as normal.  When your update is complete, check your current rules and ensure that they still match what is desired.  If not, either overwrite the original rules file with your backup, or proceed to use the ‘rules -o modify’ and/or ‘rules -o add’ commands to change the rules to match what is in your backup file.

 

Finally, if you’ve failed to back up your rules, and are not sure what the rules should be, you can deploy the recommended VIOS rules by using the following command:

$ rules -o deploy -d

 

Then, if you wish to copy these new VIOS recommended rules to your current rules file, just run:

 

$ rules -o capture

 

Note: This will overwrite any customized rules in the current rules file.

 

Applying Updates

 

Warning:

If the target node to be updated is part of a redundant VIOS pair, the VIOS partner node must be fully operational before beginning to update the target node.

 

Note:

For VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.

 

 

Instructions: Applying updates to a VIOS.

 

  1. Log in to the VIOS as the user padmin.
  2. If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.
  3. If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.

    $
     clstartstop -stop -n <cluster_name > -m <hostname >
  4. To apply updates from a directory on your local hard disk, follow the steps:
    1. Create a directory on the Virtual I/O Server.
      $
       mkdir <directory_name >

2.     Using ftp, transfer the update file(s) to the directory you created.

To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:

      1. Mount the remote directory onto the Virtual I/O Server:
        $
         mount remote_machine_name:directory /mnt

The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, follow the steps:

      1. Place the CD-ROM into the drive assigned to VIOS.
  1. Commit previous updates by running the updateios command:
    $
     updateios -commit
  2. Verify the updates files that were copied. This step can only be performed if the link to openssl was created.
    $ 
    cp <directory_path >/ck_sum.bff /home/padmin 
    $ 
    chmod 755 </home/padmin>/ck_sum.bff 
    $ 
    ck_sum.bff <directory_path > 
    If there are missing updates or incomplete downloads, an error message is displayed.

    To see how to create a link to openssl, click here.
  3. Apply the update by running the updateios command
    $
     updateios -accept -install -dev <directory_name >
  4. To load all changes, reboot the VIOS as user padmin .

$ shutdown -restart

 

Note: If shutdown –restart command failed, run swrole –PAdmin in order for padmin to set authorization and establish access to the shutdown command properly.

  1. If cluster services were stopped in step 3, restart cluster services.

$ clstartstop -start -n <cluster_name > -m <hostname >

  1. Verify that the update was successful by checking the results of the updateios command and by running the isolevel command, which should indicate that the ioslevel is now 3.1.1.21.

$ ioslevel

Post-installation Information and Instructions

Instructions: Checking for an incomplete installation caused by a loaded media repository.

 

After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.

Check the Media Repository by running this command: 
$ 
lsrep

If the command reports: "Unable to retrieve repository data due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.

 

Running the lsvopt command should show the media images.

 

Instructions: Recovering from an incomplete installation caused by a loaded media repository.

 

To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:

1.     Unload any media images

$ unloadopt -vtd <file-backed_virtual_optical_device>

2.     Reinstall the ios.cli.rte fileset by running the following commands.

To escape the restricted shell: 
$ 
oem_setup_env 
To install the failed fileset: 
# 
installp –Or –agX ios.cli.rte –d <device/directory > 
 To return to the restricted shell: 
# 
exit

3.     Restart the VIOS.

$ shutdown –restart

4.     Verify that the Media Repository is operational by running this command:

$ lsrep

Additional Information

For additional details, including known capabilities, limitations, and additional install considerations, as well as some additional instructions, please reference the readme for 3.1.1.10 located here.

Fixes included in this release

This version will include all fixes found in all previous 3.1.1.X releases.  The fixes for the previous release can be found here.

 

The list of fixes in 3.1.1.21

 

APAR

Description

IJ22637

In multybyte locale diff -i report upper&lower

IJ22346

0042-053 M_CKMAC: THERE IS NO NIM OBJECT NAMED "CERTIFICATE"

IJ20786

A potential security issue exists

IJ20963

Create 7.2 IPPs

IJ20967

max_xfer_size not to exceed config requested

IJ21137

POTENTIAL FOR SYSTEM HANG WHEN REMOVING A CPU WHILE TRACING

IJ21173

Merge not taking place after node reboot in split case

IJ21196

Uninitialized fields in the ifnet loopback device cause crash.

IJ21335

VIOS commands calling mklv/lquerypv may fail

IJ21338

VNICSERVER_CRQ PROCESS HIGH CPU USAGE

IJ21353

PTHREAD_MUTEX_DESTROY() CAN COREDUMP WITH PTHREAD TRACE LIBRARY

IJ21354

COMMANDS LIKE LSSRC OR LSGROUP CAN CORE DUMP

IJ21355

STRINGS SEGFAULT IN MBRTOWC WITH MULTIBYTE DATA

IJ21356

REPORT ALLOCATIONS ARE MISSING WITH MALLOCDEBUG=LOG SET

IJ21357

ALL TE_POLICY WERE SET TO OFF AFTER UPDATING BOS.RTE.SECURITY

IJ21358

LSUSER -A MAY NOT SHOW ALL USERS

IJ21359

CSUM DOES NOT READ OUTPUT PAST 4096 BYTES WHEN READ FROM STDIN

IJ21360

HOSTMIBD DUMPS CORE WHILE QUERYING MIB HRDEVICE

IJ21361

CHVG -G MEMORY EXHAUSTION WITH LARGE NUMBER OF PPS

IJ21362

chuser command is not showing correct error msg

IJ21364

Shift + p doesn't work at vi after cw command

IJ21365

NPIV clients unable to recover path after storage PID changed

IJ21366

unavailability of lock may some time cause cluster op to fail

IJ21368

SAN disk capacity is not displayed correctly

IJ21369

user space kdb coredumps when running vnic dev command

IJ21370

handle maxuproc value for sys0 in VIOS 3.1

IJ21371

iSCSI define children not creating new hdisk

IJ21373

Path is disabled on a dynamic tracking failure

IJ21379

vg names when similar may lead to failure in HMC.

IJ21380

FC define children migration to non-MPIO not correct

IJ21381

vfchost adapter may continually fail commands from client

IJ21384

Permission denied for /proc/<PID>/cwd

IJ21385

KDB SVMON SUBCOMMAND REPORTING UADSDPACE CORRUPT

IJ21386

SYSTEM CRASH IN BIND PROCESSOR()

IJ21387

SYSTEM CRASH WITH INTERRUPT STACK OVERFLOW WHILE DOING JFS2 IO

IJ21388

SYSTEM CRASH IN NBC_LOCATE()

IJ21390

VPM intelligent folding not supported

IJ21391

Deleting file from nfs client while audit mode is on has bug.

IJ21393

Minor fix to GZIP accelerator framework

IJ21397

STARTWPAR LATENCY DUE TO NFS FILE SYSTEMS MOUNT

IJ21398

nmon coredumps in collectSEAClients

IJ21399

nmon creating tilde files in home directory of uer.

IJ21400

WITH MULTIPLE ROUTES DEFINED NIMQUERY CAN REPORT INCORRECT GW

IJ21401

system crash in copy_context pmsvcs kernel extension

IJ21402

REMOVING LARGE NFS FILES RETURNS "NO SUCH FILE" ERROR

IJ21405

TOPAS/NMON UTILITIES HAVING VERY SLOW RESPONSE TIME

IJ21406

VIOS ABEND IN NET_MALLOC_CPU DURRING LPM

IJ21409

CAA CLCONFD HANGS DUE TO BAD SIGNAL HANDLER CODE

IJ21410

ALT_BOOT_VRMF DOES NOT MATCH BOS_MP64_VRMF

IJ21411

EMSTAT LOOPS IN SAMPLE_LOOP() WHEN IT FAILED TO CREATE THREADS

IJ21412

AIX NFS CLIENT CREATING DIRECTORY WITH GID OF -1

IJ21413

PPROF REPORTS NEGATIVE NUMBERS

IJ21414

Link Aggregation create may fail if default rules are set.

IJ21415

xstr command does not work correctly

IJ21416

Log replay error (RC_BUSY) for lrMigTraverse with isolate

IJ21419

USER I/O SLOWED DURING THICK LU RESIZING

IJ21462

CMDB MAY STOP WHEN CHANGING TAPE BLOCK_SIZE

IJ21505

lsmpio -ar shows all paths Failed when some are Available

IJ21506

query for suspend adapters should include hash character.

IJ21508

Gen4 NVMe drive VPD support

IJ21509

IBM 4767 fails EEH recovery with state ERROR (0x00208000)

IJ21527

POSSIBLE UNDETECTED DATA CORRUPTION WITH CERTAIN FIBRE CHANNEL A

IJ21563

Treat ALUA Transitioning state as non-optimized

IJ21564

VIOS 3.1.1 SSP may not recover from network loss

IJ21727

NETCD REPEATEDLY CACHING SAME ENTRY

IJ21818

imapd and pop3d entries are not inserted into /etc/inetd.conf

IJ21819

VIOSBR MAY NOT RESTORE DEFAULT GATEWAY IF IT'S A STATIC ROUTE

IJ21820

FAILED VIOSECURE/AIXPERT RULES ON VIOS

IJ21821

BACKUPIOS -NOMEDIALIB ONLY EXCLUDES VMLIBRARY IF IT IS IN ROOT

IJ21822

VIOS can crash when removing VEA from SEA

IJ21823

Cache collisions occur with disk worker tasks

IJ21824

viosupgrade may fail for input relative path name

IJ21825

TRUSTCHK FAILS WHILE ADDING MULTIPLE LIBRARIES

IJ21827

LARGE ENTRY IN .SH_HISTORY CAN CAUSE CORE DUMP FOR KSH93

IJ21829

SSP Volumes may not be listed in HMC GUI post mapping.

IJ21830

Kernel memory leak when Trusted Execution is on

IJ21831

bind to addr whose sun_path has trailing slash succeeds

IJ21879

DBX CORE DUMPING WITH WATSON2 MALLOC SUBSYSTEM.

IJ21885

getty display IBM copyright that ends with year 2019.

IJ21963

INCORRECT FORMATTING OF INTERVAL NUMBERS IN NMON RECORDING FILE

IJ21967

namespace pollution in <netdb.h>

IJ21968

SEA allowing multiple trunk adapters with different VSWITCH ID.

IJ22023

MKINSTALLP MAY FAIL WHEN CREATING ADDITIONAL LICENSE FILESET

IJ22049

SOFTWARE ERROR logged against iscsi0 during boot

IJ22069

SEGMENTATION FAULT(COREDUMP) WHEN RUNNING LSGROUP

IJ22090

INTERRUPTING USRCK WITH CTL-C CAN DELETE PASSWD/GROUP FILES

IJ22091

iSCSI login hangs if sb_max is set to 1GB or greater

IJ22101

DEPRECATED PERL FUNCTION CAUSES 'DSH -E' TO FAIL

IJ22119

SENDMAIL FAILS WHEN CALLED VIA KSH93 PIPE

IJ22147

Run time error for CMSG_FIRSTHDR and CMSG_NXTHDR

IJ22148

possible missing parenthesis ')' or ','

IJ22151

add NVME files to mksysb tape for installation support

IJ22193

Tunnel state does not go back to "Dormant" for ODT

IJ22209

NULL assignments to pointers & variables

IJ22211

Crash in iscsisw_strategy

IJ22264

SECLDAPCLNTD MAY DUMP CORE DUE TO CERTAIN SERVER ERRORS

IJ22265

MEMORY LEAK IN GETGRSET_NETGROUP()

IJ22267

PUTUSERPWX() IS NOT INCLUDED IN USERPW.H HEADER FILE

IJ22287

EAFNOSUPPORT - Address family not supported

IJ22288

Machine crashed @ soreserve+00008C

IJ22289

sendmail command is not working with TLS Functionality

IJ22290

IO HANG ON NPIV CLIENT BACKED BY SLI-4 ADAPTER ON VIOS

IJ22304

FTPD MAY HANG IF THE CLIENT NEVER CLOSES ITS DATA CONNECTION

IJ22306

LU: UPDATE LVUP_SAFE_KE TO INCLUDE SMT_LOADPIN

IJ22348

iSCSI driver improvements for LPM

IJ22377

PASSIVE CONCURRENT VG DOES NOT COME OUT OF SILENT MODE AFTER LKU

IJ22423

MULTIPLE PHASE2 TUNNELS FOR SINGLE PHASE1 CANNOT BE ESTABLISHED

IJ22437

DUPLICATE PACKETS WITH ETHERCHANNEL IN VNIC/SR-IOV ENVIRONMENT

IJ22439

SECLDAPCLNTD SUDDENLY STARTS CONSUMING LARGE AMOUNTS OF CPU

IJ22440

VIOS intermittently crashes

IJ22461

Adding a LAR, interactive mkinstallp msg issue

IJ22462

Error entry in devinst_log POST vios installation

IJ22463

NDD_ENT_LARGE_SEND SET ON VEA WITH CHKSUM_OFFLOAD=NO

IJ22464

ETHERCHANNEL MODIFICATION CRASHES SYSTEM

IJ22465

cannot add or delete multiple backup adapters in smit

IJ22466

FIND -LS DOES NOT PRINT "P" IN THE MODE FOR PIPE/

IJ22467

KRLOCK CONTENTION IN VM_FIXLMB_DR() WHEN APPS USING GETPROCS()

IJ22468

Need better solution for machine crash at soreserve

IJ22513

tmd dumps core

IJ22514

MSYNC SYSTEM CALL CAN TAKE MORE TIME ON AIX 7.2 COMPARED TO 7.1

IJ22585

SYSTEM CRASH IN PROCXMT()

IJ22586

bootinfo error installing into wpars

IJ22587

Command hang when closing iSCSI disk

IJ22588

Potential system crash when system trace is on for hook 419

IJ22603

ikekey.kdb Lock contention between ikev2d & cpsd

IJ22604

Need even better solution for machine crash at soreserve

IJ22605

RULES COMMAND MAY RETURN BOSBOOT ERROR

IJ22618

DISKS MISSING AT INSTALL TIME DUE TO ERRORS IN GET_RVG_DISKS

IJ22623

Live Update operation fails because space runs out.

IJ22639

NDD_ENABLE_ADAPTER taking 15 seconds before calling device driv

IJ22669

CAT: 0652-050 CANNOT OPEN BOS.FILESET.RTE.AL WHEN UPDATING

IJ22714

Possible undetected data corruption when rw_max_time is non-zero

IJ22738

SYSTEM CAN CRASH IN V_PFEND_FSEG WHEN WLMCNTRL COMMAND RUNNING

IJ22743

clconfd connectmon thread

IJ22754

VIOENTDD HANDLES IEEE802.3 ETHERNET FRAMES WRONGLY

IJ22767

Add VIOS request by ksys may result in false success.

IJ22789

Add support for links in mount stubs for nfs lku code

IJ22790

Fix vSCSI timer logic for LPM

IJ22821

Empty pv udid may cause error in management console

IJ22882

IPsec fails to parse IKE_AUTH with "Unrecognized Notify Error"

IJ22912

ikedb -p gives error after reboot -q

IJ22913

AIX->Windows ping hangs after SA idletimeout

IJ22933

PMLIST DUMPING CORE IN PMREADEVS

IJ22936

lpar hung @cache_request_invalidate_run+0001A

IJ22937

mlxcentdd promiscuous mode does not support RSS.

IJ22976

FD leak problem seen during ike negotiations

IJ23011

reducevg unclear on delay when waiting for inflight reclaim req

IJ23066

refresh of ike daemons not cleaning deleted IPs from netstat o/p

IJ23067

IKEv2 OnDemand filter rules are removed after Phase1 Refresh.

IJ23068

To support Mellanox Embedded SM and the latest OpenSM

IJ23073

RESULT0645-007 ATTENTION:SUBSHRC() RETURNED AN UNEXPECTED

IJ23092

SOME VFC ERRORS MAY GET LOGGED INCORRECTLY

IJ23093

AUTOMOUNTD USES UP ALL MEMORY AND CORE DUMPS

IJ23120

LDD IN AIX 7100-05-02-1832 AND 7200-03-02-1846 CAN NOT FIND LIB

IJ23121

SEGMENTATION FAULT(COREDUMP) IN PWD -P

IJ23122

Failure to commit with update_all

IJ23123

Procstack missing stack before signal reception from 7.2

IJ23124

Diag failed to format any namespace greater than 9.

IJ23125

Handle filename paths in the RTAS snap collection script

IJ23128

Crash seen during rmnode or shutdown on VIOS using SSP.

IJ23173

diff -b fails to treat carriage return as white space

IJ23174

chdev fails to change nthreads SEA attribute

IJ23176

RTB_LOCK CAUSES PERFORMANCE DEGRADATION IN AIX 7.2 TL3 SP3

IJ23190

Netmalloc police debug facility is not thread safe

IJ23222

POSSIBLE I/O PERFORMANCE PROBLEM WITH LINUX CLIENT LPARS

IJ23234

DBN never elects due to election thread not running.

IJ23235

AIX Diag fail to secure delete RDX over 1TB

IJ23236

sa_ & key_rem_lifetime are non 0 though tunnels remov

IJ23237

KDB command - Potential errors when displaying PPDA

IJ23238

Updating timezone data files to latest available for 2020

IJ23395

Adapters getting unresponsive during EEH and device config

IJ23396

RULESCFGSET FAILS AS PADMIN ON VIOS 3.1

IJ23397

IKE Phase2 SA not cleaned up when its Phase1 is deleted.

IJ23399

Performance regression in non-fastpath AIO

IJ23400

Potential LPM failure when GZIP accelerator is in use

IJ23436

STOP A WPAR WOULD UNLOAD RANDOM/URANDOM FOR THE LPAR SOMETIMES

IJ23437

Diag failed to display microcode for PCIe3 10Gb 4-Port FCoE

IJ23594

jumbo_frames setting incorrect for adapter added to EtherChannel

IJ23628

Reduce CPU consumption by mlxcentdd driver

IJ23711

Crash when kproc takes over 10 seconds to initialize and execute

IJ23731

REDUCE CPU CONSUMPTION IN ENTCORE

IJ23741

UPGRADING TO AIX 7.2 TL4 TRUNCATES /ETC/MAIL/ALIASES

IJ23742

DB connection string in multiple IP conn can have junk in string

IJ23743

lpar is hanging with ref. code 888 102 700

IJ23770

VIOS may crash or deadlock

IJ23863

Cannot map new SSP LU

IJ24004

Error accessing NFS files during LKU

IJ24059

privileges for non-root users to use mail/mailx/sendmail

IJ24176

SSP database election taking a very long time or not completing.

IJ24184

AIX lpar may crash on a PHYP error to register CRQ

IJ24307

vhost or vfchost adapter may hang or crash

IJ24319

Error entry in update and cons log

IJ24323

Crash in dbUpdatePMap after truncate

IJ24572

Fix /usr/sbin/emgr[46]:RC:not found msg

IJ24575

Kernel error during interrupt deconfiguration

IV97329

Install images for devices.common.IBM.soe