PACKAGE: Update Release 2.2.5.10
IOSLEVEL: 2.2.5.10
|
VIOS level is |
NIM Master level
must be equal to or higher than |
|
Update Release 2.2.5.10 |
AIX 6100-09-08 or AIX 7100-04-03 |
In June 2015, VIOS introduced the minipack as a new service stream delivery vehicle as well as a change to the VIOS fix level numbering scheme. The VIOS “fix level” (the 4th number) has changed to two digits. For example VIOS 2.2.5.1 has been changed to VIOS 2.2.5.10. Please refer to the VIOS Maintenance Strategy here for more details regarding the change to the VIOS release numbering scheme.
Be sure to heed all minimum space requirements before installing. For this version, target at least 900MB available in the ‘/’ directory.
Review the list of fixes included in Update Release 2.2.5.10
To take full advantage of all the functions available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 2.2.5.10.
Microcode or system firmware downloads for Power Systems
The VIOS Update Release 2.2.5.10 includes the IVM code, but it will not be enabled on HMC-managed systems. Update Release 2.2.5.10, like all VIOS Update Releases, can be applied to either HMC-managed or IVM-managed VIOS.
Update Release 2.2.5.10 updates your VIOS partition to ioslevel 2.2.5.10. To determine if Update Release 2.2.5.10 is already installed, run the following command from the VIOS command line.
$ ioslevel
If Update Release 2.2.5.10 is installed, the command output is 2.2.5.10.
The following requirements and limitations apply to Shared Storage Pool (SSP) features and any associated virtual storage enhancements.
Software Installation
SSP Configuration
|
Feature |
Min |
Max |
Special* |
|
Number of VIOS Nodes in Cluster |
1 |
16 |
24 |
|
Number of Physical Disks in Pool |
1 |
1024 |
|
|
Number of Virtual Disks (LUs) Mappings in Pool |
1 |
8192 |
|
|
Number of Client LPARs per VIOS node |
1 |
250 |
400 |
|
Capacity of Physical Disks in Pool |
10GB |
16TB |
|
|
Storage Capacity of Storage Pool |
10GB |
512TB |
|
|
Capacity of a Virtual Disk (LU) in Pool |
1GB |
4TB |
|
|
Number of Repository Disks |
1 |
1 |
|
|
Capacity of Repository Disk |
512MB |
1016GB |
|
|
Number of Client LPARs per Cluster |
1 |
2000 |
|
*These features have special hardware requirements that must be met:
Other notes:
Network Configuration
Storage Configuration
Shared Storage Pool capabilities and limitations
Please ensure that your rootvg contains at least 30 GB and that there is at least 4GB free space before you attempt to update to Update Release 2.2.5.10. Run the lsvg rootvg command, and then ensure there is enough free space.
Example:
$ lsvg
rootvg
VOLUME GROUP: rootvg VG IDENTIFIER: 00f6004600004c000000014306a3db3d
VG STATE: active PP SIZE: 64 megabyte(s)
VG PERMISSION: read/write TOTAL PPs: 511 (32704 megabytes)
MAX LVs: 256 FREE PPs: 64 (4096 megabytes)
LVs: 14 USED PPs: 447(28608 megabytes)
OPEN LVs: 12 QUORUM: 2 (Enabled)
TOTAL PVs: 1 VG DESCRIPTORS: 2
STALE PVs: 0 STALE PPs: 0
ACTIVE PVs: 1 AUTO ON: yes
MAX PPs per VG: 32512
MAX PPs per PV: 1016 MAX PVs: 32
LTG size (Dynamic): 256 kilobyte(s) AUTO SYNC: no
HOT SPARE: no BB POLICY: relocatable
PV RESTRICTION:
none INFINITE
RETRY: no
If you are planning to update a version of VIOS lower than 2.1, you must first migrate your VIOS to VIOS version 2.1.0 using the Migration DVD. After the VIOS is at version 2.1.0, the Upgrade/Fixpack 2.2.5.10 must be applied to bring the VIOS to the latest Fix Pack VIOS 2.2.5.10 level.
Note that with the Update Release 2.2.5.10, a single boot alternative to this multiple step process is available to NIM users. NIM users can update by creating a single, merged lpp_source that combines the contents of the Migration DVD with the contents of this Update Release 2.2.5.10.
A single, merged lpp_source is not supported for a VIOS that uses SDDPCM. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location:
SDD and SDDPCM migration procedures when migrating VIOS from version 1.x to version 2.x
After the VIOS migration is complete, from 1.X to
2.X, you must set the Processor Folding, described here under Migration DVD:
Instructions to disable Processor Folding are detailed at the link below.
See the “Migration DVD” section:
Virtual I/O Server support for Power Systems
The current level of VIOS must be between 2.2.1.1 and 2.2.4.x, you can put 2.2.5.10 in a location and do the update using updateios command
Before installing the VIOS Update Release 2.2.5.10
The update could fail if there is a loaded media repository.
To check for a loaded media repository, and then unload it, follow these steps.
The Virtual I/O Server (VIOS) Version 2.2.2.1 or later, supports rolling updates for SSP clusters. The VIOS can be updated to Update Release 2.2.5.10 using rolling updates
If your current VIOS is running with Shared Storage Pool from 2.2.1.1 or 2.2.1.3, the following information applies:
A cluster that is created and configured on VIOS Version 2.2.1.1 or 2.2.1.3 must be migrated to version 2.2.1.4 or 2.2.1.5 prior to utilizing rolling updates. This allows the user to keep their shared storage pool devices. When VIOS version is equal or greater than 2.2.1.4 and less than 2.2.5.10, the user needs to download 2.2.5.10 update images into a directory, then update the VIOS to Update Release 2.2.5.10 using rolling updates.
If your current VIOS is configured with Shared Storage Pool from 2.2.1.4 or later, the following information applies:
The rolling updates enhancement allows the user to apply Update Release 2.2.5.10 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.
To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:
The VIOS SSP software monitors node status and will automatically upgrade the cluster to make use of the new capabilities when all the nodes in the cluster have been updated, “cluster –status –verbose” reports “ON_LEVEL”.
There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link. To verify the VIOS update files, follow these steps:
$ oem_setup_env
Create a link to openssl
# ln -s /usr/bin/openssl
/usr/ios/utils/openssl
Verify the link to openssl was created
# ls –alL /usr/bin/openssl
/usr/ios/utils/openssl
Both files should display similar owner and size
# exit
Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.
If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.
Note: While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.
If your current level is between 2.2.1.1 and 2.2.2.1, you can directly apply 2.2.5.10 updates. This fixes an update problem with the builddate on bos.alt_disk_install.boot_images fileset.
If your current level is 2.2.2.1, 2.2.2.2, 2.2.2.3 or 2.2.3.1, you need to run “updateios” command twice to get bos.alt_disk_install.boot_images fileset update problem fixed.
Run the following command after the step of “$ updateios -accept -install -dev <directory_name>” completes.
$updateios -accept
-dev <directory_name>
Depending on the VIOs level one or
more of the LPPs below may be reported as "Missing Requisites", and
they may be ignored.
MISSING REQUISITES:
X11.loc.fr_FR.base.lib 4.3.0.0
bos.INed
6.1.6.0
bos.loc.pc.Ja_JP
6.1.0.0
bos.loc.utf.EN_US
6.1.0.0
bos.mls.rte
6.1.x.x
bos.mls.rte
6.1.9.200
bos.svprint.rte
6.1.9.200
# Base Level Fileset
# Base Level Fileset
# Base Level Fileset
# Base Level Fileset
# Base Level Fileset
# Base Level Fileset or #Fileset Update
# Fileset Update
Applying updates
WARNING: If the target node to be updated is part of a
redundant VIOS pair, ensure that the VIOS partner node is fully operational
before beginning to update the target node. NOTE that for VIOS nodes that are
part of an SSP cluster, the partner node must be shown in 'cluster -status'
output as having a cluster status of OK and a pool status of OK. If the target
node is updated before its VIOS partner is fully operational, client LPARs may
crash.
·
Create a directory on the Virtual I/O Server.
$ mkdir <directory_name>
· Using ftp, transfer the update file(s) to the directory you created.
To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:
·
Mount the remote directory onto the Virtual I/O
Server.
$ mount remote_machine_name:directory /mnt
The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, following the steps:
· Place the CD-ROM into the drive assigned to VIOS.
Note: If “shutdown -restart” command failed, please run “swrole – PAdmin” in order for padmin to set authorization and establish access to the “shutdown” command properly.
Checking for an incomplete installation caused by a loaded media repository
After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.
Check the Media Repository by running this command:
$ lsrep
If the command reports: "Unable to retrieve repository date due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.
Running the lsvopt command should show the media images.
To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:
NIM backup, install and update information
Use of NIM to back up, install and update the VIOS is supported.
For further assistance, on the back up and install using NIM refer to the NIM documentation.
Note: For install always create the SPOT resource directly from the VIOS mksysb image.
Do NOT update the SPOT from an LPP_SOURCE.
Use of NIM to update the VIOS is supported as follows:
Ensure that the NIM Master is at the appropriate level to support the VIOS image. Refer to the above table in the "Package information" section.
On the NIM Master use the operation "updateios" to update the VIO Server.
Sample: "nim -o updateios -a lpp_source=lpp_source1 ... ... ..."
For further assistance, refer to the NIM documentation.
On the NIM Master use the
operation "alt_disk_install" to update an alternate disk copy of the
VIO Server.
Sample: “nim -o
alt_disk_install -a source=rootvg
-a disk=target_disk -a
fix_bundle=(Value) … … …”
For
further assistance, refer to the NIM documentation.
If NIM is not used to update the VIOS, only the updateios or the alt_root_vg command from the padmin shell can be used to update the VIOS.
Installing the latest version of
This release of VIOS contains several enhancements. These enhancements are in the area of POWER virtualization. The following list provides the features of each element by product area.
Note: Version 6.1.0, the previous version of Tivoli TSM, is still shipped and installed from the VIOS installation DVD.
The Tivoli TSM filesets are now being shipped on the VIOS Expansion Pack, with the required GSKit8 libraries.
The following are sample installation instructions for the new Tivoli TSM filesets:
The
list of fixes in 2.2.5.10
|
APAR |
Description |
|
IV61308 |
HANG
IN ELXENT_BUGOUT |
|
IV65101 |
CAA
MKWPAR -S CREATES WPAR WITH SPINNING CLCOMD |
|
IV67228 |
SYSTEM
CRASH DUE TO RECURSIVE LOCK IN FC5287 DRIVER |
|
IV67308 |
VERY
SLOW NETWORK THROUGHPUT FROM VIOC |
|
IV69355 |
SEA
LARGESEND CAN CAUSE TCP BAD HEADER OFFSET ON VIRTUAL CLIENT |
|
IV69897 |
AIX
/USR/SYSV/BIN/DF COMMAND REPORTS INCORRECT VALUES |
|
IV70553 |
SAS
CD DRIVE MAPPINGS CHANGED WHEN VIOS REBOOTED |
|
IV70843 |
AIXPERT
MAY ADD WRITE PERMISSION TO PROGRAMS |
|
IV70899 |
FC1763/FC5899
supported port may become unresponsive |
|
IV71204 |
rootcronjobck
fails to handle symlink |
|
IV71882 |
Invalidate
on vid matched pvid of non-default trunk adapter. |
|
IV71906 |
LVS
AND VGS GET DISPLAYED WHEN THEY SHOULD BE HIDDEN. |
|
IV72007 |
INCORRECT
READ MAY OCCUR DURING JOINVG |
|
IV72025 |
Assert
in emfsc_free_cmd_elem |
|
IV72133 |
caa:
no gossip transmission on boot can lead to split-brain |
|
IV72147 |
CFGIPSEC
NOT PROPERLY HANDLING COMMENTS IN NEXTBOOT FILE |
|
IV72562 |
SFW
SFWCOM APPEARS UP TO CAA WHEN IT IS NOT FUNCTIONAL |
|
IV72893 |
CLCOMD
CAN USE TOO MUCH CPU WHEN AHAFS NOT ACCESSIBLE |
|
IV73000 |
INCORRECT
DETAIL IN VIOD_ALERT_EVENT IF CM DB FS CANNOT BE CHECK |
|
IV73642 |
LSDEV
-TYPE ENT4SEA EXCLUDES ROCE ADAPTER |
|
IV73705 |
usrck
does not catch non-executable shell |
|
IV73716 |
partitions
with more than 87,380 LMBs may crash |
|
IV73758 |
EXECUTING
STOPSRC -G IKE CAN HANG TMD |
|
IV73765 |
alert
-list option should list alerts of all tiers. |
|
IV73767 |
Adapter
in unknown state with nddctl -r |
|
IV73768 |
EXTENDVG
OF CONC VG MAY FORCE THE VG OFFLINE ON REMOTE NODE |
|
IV73769 |
system
crash in hd_reduce(), lvm layer |
|
IV73770 |
joinvg
in concurrent VG may put disks in missing |
|
IV73838 |
caa:
inactive node fails to generate remote node_up ahafs event |
|
IV73951 |
I/O
may hung during SCSI ACA Error Condition. |
|
IV73952 |
cleanup
SRC VIOS mappings after client lpar is remote restarted. |
|
IV73954 |
system
crash with livedump |
|
IV73955 |
Unclear
script callout errors |
|
IV73976 |
A
potential security issue exists CVE-2014-3566 |
|
IV73989 |
Node
cle_globid range incorrect |
|
IV73994 |
incorrect
VPD information for Integrated ethernet adapter |
|
IV74097 |
Slow
NIM install/telnet/tcp connections |
|
IV74184 |
The
second port on Travis3-EN doesn't work |
|
IV74329 |
CVE-2015-0261
and CVE-2015-2154 tcpdump vulnerablity fix |
|
IV74484 |
ENTSTAT
ON SEA FAILS WITH ENTSTAT_MODE ENVIRONEMT VARIABLE |
|
IV74606 |
ALT_DISK_COPY
ON 4K DISK TRIGGERS LVM_IO_FAIL |
|
IV74650 |
caa:
repository disk replacement may fail |
|
IV74726 |
Etherchannel
not recovering after port reset |
|
IV74927 |
A
potential security issue exists CVE-2015-2808 |
|
IV74946 |
clconfd
lvm conflict with chrepos |
|
IV75001 |
MIGRATEPV
FAILURE MAY CAUSE IO HANG IN CONCURRENT VG |
|
IV75057 |
rmvdev
fails with an LU backed vtd. |
|
IV75100 |
Restore
seems to hang. |
|
IV75102 |
SSP
Lu's mapping goes missing after remote restart |
|
IV75273 |
LSLDAP
KEEPS ON FAILLING WHEN LDAP SERVER CLOSES CONNECTION |
|
IV75290 |
Multiple
client_partition entries cause mapping issues. |
|
IV75364 |
CAA:
UNEXPECTED START_NODE BY PEER NODE LEADS TO AST PANIC |
|
IV75387 |
CAA:
SYSTEM WILL CRASH IF GOSSIP PACKET HAS ID = 0 |
|
IV75388 |
updateios
gives incorrect error codes/messages for some options |
|
IV75480 |
LPM
validation fails if some port bounce happens on SAN |
|
IV75495 |
CODEGCHECK
MIGHT FAIL WITH FALSE ERROR, DISPLAYING SCRIPTED |
|
IV75538 |
caa:
defined pv that matches repo pvid causes mkcluster to fail |
|
IV75589 |
SYSTEM
CRASHES IN ICMCLOSEQP1 |
|
IV75591 |
Resume
can fail with HMC code HSCLA27F after validation pass. |
|
IV75627 |
Cluster
create could fail |
|
IV75685 |
LPM
can fail with HMC to MSP connection timed out error |
|
IV75719 |
FCSTAT
-N WWNXXXX FCS0 RETURNS 0 FOR FCSTAT OUTPUT |
|
IV75738 |
LSSEC
PERFORMANCE SUFFERS WHEN EFS IS ENABLED |
|
IV75879 |
AIXPERT:
RELATIVE CRON JOB SPECIFICATIONS MAY FAIL |
|
IV75880 |
AIXPERT:
FAILS TO HANDLE PARENT DIRECTORIES WITH ROOTCRNJOBCK |
|
IV75883 |
DST
with SRIOV dedicated failed in Stage 3 |
|
IV76033 |
Some
SSP VTDs are not restored during cluster restore |
|
IV76130 |
Invalid
repository reserve policy not detected on remote nodes |
|
IV76151 |
IKED
LOOPS AND CAUSES CPU LOAD WHEN 0-BYTE DATAGRAM IS PRESENT |
|
IV76158 |
SYSTEM
CRASH AFTER RENDEV ON FCS ADAPTER |
|
IV76194 |
VLAN
ADAPTER ON PCIE2 4-PORT ADAPTER(10GBE SFP+) DROPS PACKETS |
|
IV76204 |
ISCSI
TOE SENDING IO TO WRONG TARGET |
|
IV76214 |
VIO
Change Mgmt daemon can core dump |
|
IV76216 |
LUN
discovery may fail during cfgmgr |
|
IV76243 |
ETHERCHANNEL
WITH CT3 ADAPTER MAY HANG |
|
IV76254 |
Unable
to start pool after a failed FG operation |
|
IV76256 |
Unlock
adapter is not required when lock did not happen earlier |
|
IV76359 |
Do
not remove adapter if suspend info is not updated |
|
IV76508 |
EFSENABLE
-D WRT LDAP OPERATION FAILS IN SOME SCENARIOS |
|
IV76512 |
Packets
with old MAC are received after changing MAC |
|
IV76529 |
System
crash while running hxecom with modified ent attributes |
|
IV76530 |
VMLibrary
size may be listed as zero |
|
IV76538 |
SCTP
heartbeats are not getting sent within RTO of the path |
|
IV76591 |
0514-061
CANNOT FIND A CHILD DEVICE ERRORS ON FC ADAPTERS |
|
IV76723 |
CAA
UNICAST CLU: DMS ON LAST NODE DUE TO INCORRECT DPCOM STATE |
|
IV76806 |
LSGROUP
INCORRECTLY CACHES LDAP USER INFORMATION |
|
IV76817 |
LPM
validation or some VIOS function may give ODM lock errors |
|
IV76821 |
'devrsrv'
command to force clear SCSI-2 reserve on a vSCSI fails |
|
IV77175 |
CAA:
MERGE FAILURE DUE TO STALE JOIN_PENDING FLAG. |
|
IV77179 |
viosecure
command fails during rule failure with file option |
|
IV77182 |
cluster
Restore may fail in 1 node cluster with PowerVC |
|
IV77183 |
System
crash during adapter EEH recovery. |
|
IV77471 |
Callback
with NDD_LS_DOWN when EEH detected |
|
IV77472 |
lnc2ent
kdb command fails due to corrupted command table entry. |
|
IV77475 |
ADD
FOR POWERVC RESERVE_LOCK POLICY USING EMC 5.3.0.6 OR OLDER |
|
IV77506 |
CACHEFS
CRASHES IN CFIND() |
|
IV77509 |
ABEND
IN RESET_DECV |
|
IV77510 |
SYSTEM
CRASH IN REMOVING THE SEA ADAPTER BY RMDEV COMMAND |
|
IV77522 |
Disks
belonging to cluster are shown as free. |
|
IV77529 |
DISK
NORMAL OPEN FAILS WITH EACCES |
|
IV77670 |
DIAG
RETURNED 2E41-103: CHECKSUM VERIFICATION TEST FAILED |
|
IV77687 |
ALLOW
FC ATTRIBUTES TO BE SHOWN AND CHANGEABLE VIA SMIT |
|
IV77744 |
Removing
SEA device causes hang, SEA threads hang |
|
IV77964 |
CAA:
CHREPOS -C INCORRECTLY SAVES NODE_LOCAL VALUE TO REPO DISK |
|
IV78144 |
cluster
-status command does not always show pool status |
|
IV78187 |
DSI
IN ENTCORE_TX_SEND IN MLXENTDD |
|
IV78360 |
LDAP
USER HAS ADMCHG SET AFTER CHANGING OWN PASSWORD |
|
IV78412 |
FAILURE
OF VIOSBR (VIRTUALCFG) DOESN'T REMOVE WORKING FILES |
|
IV78416 |
SECLDAPCLNTD
INVALID CACHE ATTRIBUTE |
|
IV78419 |
FC5899
IS MISSING SMIT PANEL FOR CHANGING MEDIA SPEED. |
|
IV78420 |
NPIV
adapter becomes unresponsive |
|
IV78422 |
Repository
Disk is shown as free when it is actually in use |
|
IV78425 |
ROOTCRNJOBCK
FAILS TO HANDLE RELATIVE SYMLINKS & SYMLINK CHAINS |
|
IV78444 |
LOOPMOUNT
COMMAND MAY FAIL FOR READ-ONLY NFS MOUNT |
|
IV78453 |
IMPROVED
DRIVER'S FAIRNESS ALGORITHM TO AVOID I/O STARVATION |
|
IV78454 |
IMPROVED
DRIVER'S FAIRNESS LOGIC TO AVOID I/O STARVATION |
|
IV78502 |
LOOPING
IN EFC_FREE_LOGIN_TBLE |
|
IV78549 |
CRASH
DUE TO BRKPOINT IN GXIB_RAS_REGISTER CALL DURING BOOT |
|
IV78576 |
CRFS
-A QUOTA=NO SHOULD HAVE FAILED DUE TO INVALID ATTRIBUTE |
|
IV78682 |
Disk
validation for LPM of NPIV client fails |
|
IV78830 |
NPIV
CLIENT LPAR REBOOT CAN HANG THE VIOS |
|
IV78884 |
ALT_DISK_COPY
MAY FAIL WHEN MOUNTING FILESYSTEMS |
|
IV78895 |
NPIV
Migration failed with Function npiv_phys_spt tried to |
|
IV78897 |
LU-level
validation for LPM fails with IBM i or Linux clients |
|
IV78899 |
System
crash in entcore_link_change_nic_callback() |
|
IV78900 |
Removing
certain virtual devices incorrectly fails. |
|
IV79060 |
ABEND
IN NMENT_FREE_RX |
|
IV79066 |
CLMIGCHECK
GIVES WARNING ON SYSLOG.CONF UPDATE |
|
IV79067 |
CLMIGCHECK
GIVES RESERVE ERROR ON REPOSITORY DISK |
|
IV79069 |
VALID
AIX LEVELS MIGHT BE INCORRECTLY IDENTIFIED AS INVALID. |
|
IV79073 |
MISSING
INFORMATION FROM CLMIGCHECK ERROR MESSAGE |
|
IV79074 |
CLMIGCHECK
FAILS IF NETSVC.CONF CONTAINS COMMENTED HOSTS LINES |
|
IV79281 |
CLMIGCHECK
MIGHT FAIL ON CLUSTERS WITH MORE THAN TWO NODES. |
|
IV79303 |
IO.TEM
CAN CRASH DURING THE PROCESSING OF FAILED ASYNCHRONOUS |
|
IV79469 |
LU count
listed in tier list output is incorrect. |
|
IV79471 |
Some
SSP VTDs missing after restore operation |
|
IV79516 |
VKE_INFO
QUEUE FULL ERROR DETAIL MESSAGE |
|
IV79634 |
FAILED
PATH ON A CLOSED DISK MAY NOT RECOVER AFTER DISK REOPEN |
|
IV79658 |
LEVEL.OT
MIGRATIONS FAIL IF ALL NODES NOT AT THE SAME CAA |
|
IV79710 |
NIMADM
FAILS WHEN MASTER IS BOOTED FROM BOS_HD5 |
|
IV79729 |
CLASS
3 NAMESERVER QUERY ODM SUPPORT FOR LEGACY FC ADAPTER |
|
IV79874 |
SEA
CONTROL CHANNEL & TRUNK VIRTUAL ADAPTER SHARE PVID CRASH |
|
IV79991 |
FAST_FAIL
MAY NOT WORK WHEN THE IMM_GID_PN ENABLED |
|
IV80113 |
viosbr
overwrites backups with frequency option. |
|
IV80127 |
NIB
ETHERCHANNEL WITH SR-IOV VF PORT PROBLEM |
|
IV80151 |
SLOW
HA EVENT PROCESSING IN LINKED CLUSTER DUE TCPSOCK RESETS |
|
IV80435 |
TRUSTCHK
-U OUTPUT INVALID ATTRIBUTES FOR HARDLINKS & SYMLINKS |
|
IV80569 |
MUSENTDD'S
RECEIVE PATH HANGS WHEN IT RECEVIES CERTAIN SIZE PKT |
|
IV80598 |
System
crash after cachefs forced unmount |
|
IV80689 |
LNCENTDD:
MULTICAST ADDRS LOST WHEN PROMISCUOUS MODE TURNED OFF |
|
IV80732 |
ISAKMPD
CORE DUMPED IN SPI_PROTO DESTRUCTOR |
|
IV80871 |
Race
in lncentdd/lnc2entdd driver may make adapter unusable. |
|
IV81016 |
When
the catalog path is invalid artex commands coredump. |
|
IV81022 |
ISAKMPD
CORE DUMP AT COPY_REPL |
|
IV81023 |
NETSTAT
& ENTSTAT FOR ETHERCHANNELS WITH SRIOV DO NOT SHOW MAC |
|
IV81024 |
MKFS
-V JFS2 -O LOG=INLINE /DEV/LOOP0 WITH IV79296 INSTALLED |
|
IV81223 |
HMC
reports that VIOS is busy and not responding to queries |
|
IV81241 |
MELLANOX
V2 DRIVER LOGS LINK UP AND LINK DOWN DURING REBOOT |
|
IV81297 |
VIO
CLIENT CRASHES IN DISK DRIVER DURING LPM WITH GPFS AND PR SH |
|
IV81352 |
VM
deploy fails when using NIC adapters |
|
IV81454 |
DSI
IN RRHBA_QUERY_NIC |
|
IV81462 |
DF
AND LSFS MAY LIST THE WRONG FILESYSTEM |
|
IV81739 |
LPM:
MIGMGR(FIND_DEVICES -T VETH) RC=8 ON DESTINATION VIOS |
|
IV81756 |
VIOS
may crash after using SSP image management in IBM Director |
|
IV81820 |
CM
ATTRIBUTE: MISSING MPIOALGORITHM FOR POWERPATH PVS |
|
IV81839 |
Virtual
tape devices do not configure after upgrading VIOS |
|
IV81840 |
DEVICE
IPSEC_V4 MAY COME UP DEFINED AT BOOT |
|
IV81854 |
Some
objects may be missing in list presented to HMC |
|
IV81936 |
May
lose access to one or more NPIV disks |
|
IV81937 |
Segfault
may occur in ioscli vg or lv related commands. |
|
IV81967 |
UPDATEIOS:REMOVING
INSTALLED EFIX FAILS DUE TO GARBAGE CHARACTER |
|
IV82022 |
LU
-RESIZE NOT RECOGNIZED ON CLIENT AND SCF LOCK ERROR |
|
IV82080 |
SEGMENTATION
FAULT IN RULESCFGSET IF MOTD BIGGER THAN 1024 CHARS |
|
IV82145 |
IPREPORT
DOES NOT DISPLAY TCP OPTION 14 (TCPOPT_ALTCKSUM) |
|
IV82194 |
CRASH
DURING VIOENT CALLBACK WHEN USED WITH ETHERCHANNEL |
|
IV82195 |
SR-IOV
TX_TIMEOUT DEFAULTS TO 30 SECONDS |
|
IV82197 |
LPM-ED
CLIENTS TEMPORARILY LOOSE CONNECTIVTY DUE TO RARPS. |
|
IV82449 |
VIRTUAL
ETHERNET ADAPTER DRIVER MAY GOES INTO DEAD STATE. |
|
IV82461 |
VIOS
may rarely crash during LUN-level validation for LPM |
|
IV82463 |
Adapters
using lncentdd driver may log EEH as permanent Error |
|
IV82577 |
UNMIRRORVG
ROOTVG MAY HANG WITH FW-ASSISTED DUMP & HD6 |
|
IV82579 |
SLOW
HA EVENT PROCESSING IN LINKED CLUSTER DUE TCPSOCK RESETS |
|
IV82596 |
SYN
NOT RECEIVED WHEN VEA CLIENT TURN OFF CHECKSUM OFFLOAD |
|
IV82627 |
CAA(MULTICAST):
A NODE MAY NOT SEE A REBOOTED NODE AS UP |
|
IV82694 |
VIO
Server using 10 Gb PCIe adapters and large_send may crash |
|
IV82728 |
SECONDARY
GROUP NOT DETERMINED FOR OLDER NETIQ LDAP SERVERS |
|
IV82752 |
PACKET
ADJUSTED MULTIPLE TIMES BY RRHBADD DRIVER |
|
IV82795 |
VIOS
CRASH WHEN CREATING SEA IN LOW MEMORY CONDITION |
|
IV82983 |
viosbr
-restore not restoring other nodes except initiator node |
|
IV83078 |
VIOS
may crash when doing LUN-level validation for LPM |
|
IV83079 |
trustchk
error on /var/adm/cron/log after migration |
|
IV83100 |
Handle
pv backed virtual target devices during suspend operation |
|
IV83121 |
After
viosecure -undo, viosecure -view reports error |
|
IV83143 |
I/O
HANG IN EFC_FREE_LOGIN_TBLE |
|
IV83212 |
HOSTNAME
ISSUES PREVENT NODE FROM JOINING THE CAA CLUSTER |
|
IV83291 |
NPIV
client hang when cancel command fails |
|
IV83544 |
TRUSTCHK
-U FAILS FOR ALLOW_OWNER ALLOW_GROUP ALLOW_ALL |
|
IV83615 |
ROLLING
UPGRADE FROM DBV3 TO V4 FAILS |
|
IV83637 |
DRW_LOCK_WRITE()
BLOCKING READ THREADS CAUSE HANG. |
|
IV83875 |
SECLDAPCLNTD
MAY FAIL TO HANDLE LONG PASSWORD HASH STRINGS |
|
IV84242 |
VM
validation fails if nondisk type LU configured to NPIV client |
|
IV84341 |
WRONG
UDP FILTERS ADDED BY AIXPERT IPSECSHUNPORTS |
|
IV84449 |
TCBCK
-Y ALL IS RUN AT FIRSTBOOT FROM ALTERNATE DISK IN TCB ENV |
|
IV84470 |
CRASH
DUE TO POSSIBLE MEMORY LEAK IN CAA |
|
IV84478 |
MULTIPLE
DUPLICATE PDAT ODM ENTRIES FOR MPIOAPDISK |
|
IV84555 |
MAC/VLAN
ACL status incorrectly displayed when PVID enabled. |
|
IV84636 |
BOOTPD
DOESN'T FIND ROUTE WITH MANY NETWORK INTERFACES IN USE |
|
IV84649 |
LPM
fails when disk's unique_id has special characters |
|
IV84661 |
Removing
interface,when upgrading FW.Move hang state for FC#EN0H |
|
IV84677 |
CACHE
METHOD DOESN'T SET PROD FLAG CORRECTLY. |
|
IV84704 |
LARGE
RECEIVE ON VIOS IS SLOW WHEN VIO CLIENT HAS CHKSUM OFF |
|
IV84767 |
FAILOVER
HAPPENS ON 802.3AD ETHERCHANNEL WHILE REBOOT |
|
IV84769 |
PANIC
IN TSTART VIA SEAHA_PROCESS_DSCV_INIT |
|
IV84776 |
NODE
CRASHED |
|
IV84833 |
System
crash issuing slot reset after returning EEH Suspend busy |
|
IV84889 |
CAA
UNUSABLE NET_ADDR ON REPOSITORY DISK AFTER CHANGE BOOT IP |
|
IV84953 |
CM
daemon runs out of memory and thus restarts. |
|
IV84985 |
EEH
Resume failure can cause restart to set invalid device state |
|
IV85080 |
Crash
due to race condition of between DEAD and Close |
|
IV85145 |
CONSTANT
DISK_ERR4 ERRORS FOR INTERNAL SCSI DISKS IF HEALTH CHEC |
|
IV85215 |
RDMAcore
returns error if suspend is called more than once. |
|
IV85255 |
ADDING
AUDIT CONFIG FULLPATH OPTION |
|
IV85311 |
Promiscuous
or All mcast flags still shown as set after a close |
|
IV85393 |
system
crash running get_adapter with trace level >= 5 |
|
IV85395 |
alt_disk_mksysb
hangs without the absolute path to device |
|
IV85423 |
MOUNT
MAY FAIL REPORTING MEDIA IS NOT FORMATTED |
|
IV85460 |
ABEND_TRAP
FROM CLOCK |
|
IV85508 |
caa:
core dump if netmon.cf entries are defined |
|
IV85593 |
NFS3
OPEN FAILURE AFTER NFS3 OPEN WITH O_DIRECT AND O_CIO FAILS |
|
IV85670 |
VARYONVG
HANG IN SCSIDISK_CLOSE() DURING BOOT |
|
IV85676 |
Repos
DOWN event on create led to crash |
|
IV85884 |
EEH
Exit after performing Hot/Fundamental reset after FW update |
|
IV85886 |
AIXPERT
PREREQS ARE NOT MAINTAINED AFTER APPLYING RULES |
|
IV85888 |
caa:
clcomd fails to handle local internal bound ip address |
|
IV85891 |
DSI
CRASH IN VIOENT_OUTPUT |
|
IV85895 |
ECH_CANNOT_FAILOVER
ERROR WHEN REBOOTING |
|
IV86129 |
Fix
CVE-2015-7575 in imap,pop3 |
|
IV86237 |
Possible
race condition between ctrc suspend and trace operation |
|
IV86408 |
VIOS
fails with adapter in use message during LPM |
|
IV86523 |
SYSTEM
MAY HANG WHEN UPGRADING OR REMOVING BOS.RTE.SECURITY |
|
IV86535 |
system
crash while using adapter with FC#EN0S and EN0W |
|
IV86538 |
SYNCLVODM
IS SLOW WHEN THERE ARE MANY DISKS CONFIGURED |
|
IV86577 |
System
crash due to stack overflow when errlogging on slih path |
|
IV86666 |
mkvopt
command allows vopt device names with special characters |
|
IV86678 |
PACKETS
ARE SEEN TWICE IN IPTRACE |
|
IV86679 |
parallel
importpv and reboot fails the importpv operation. |
|
IV86684 |
handle
large image file copies |
|
IV86792 |
Removal
of more than one node from a cluster was giving error |
|
IV86794 |
Rolling
Upgrade does not finish |
|
IV86861 |
ERROR
MESSAGE DURING REPLACEPV NOT RELEVANT |
|
IV87015 |
clmigcheck
fails to find any shared disks |
|
IV87020 |
VM
deploy fails with VIOS_VSCSI_HOST err (relative port id=0) |
|
IV87053 |
IPTRACE
-L DOES NOT ROTATE LOGFILE IF LOGSIZE MORE THAN 2GB |
|
IV87134 |
VIOS
crash in target_cdt_add |
|
IV87309 |
CRASH
IN XHCI_OPEN WHEN ACCESSING /DEV/USBHC0 |
|
IV87315 |
CAA
CLCONFD CORE PTH_USCHED._USCHED_DISPATCH_FRONT._CHK_RESTART |
|
IV87496 |
The
validation fails, while migrating the client partitition |
|
IV87670 |
IMPROVE
HANDLING OF UNDETERMINED DISK ERRORS IN MPIO CONFIGURATI |
|
IV87701 |
Restore
fails for the max_transfer size of the hdisks. |
|
IV87704 |
LPM
will not start with a VASI Open error |
|
IV87734 |
CLUSTER
HEARTBEAT SETTINGS SMIT MENU MAY SHOW VALUE AS ZERO |
|
IV87738 |
cluster
backup through viosbr command gives segmentation fault. |
|
IV87742 |
Do
not use FC port if all NPIV ports are in use |
|
IV87743 |
Displaying
cluster status during cluster node out of network |
|
IV87775 |
IMPROVE
HANDLING OF ABORTED COMMANDS |
|
IV87913 |
SYSTEM
CRASH WITH NPIV_VALIDATE_DO_PORT_LOGIN |
|
IV87957 |
FC5899
ENTSTAT PRINTS 1818495488 FOR BAD PACKET COUNT IN NON-C |
|
IV87958 |
DURING
FCS ADAPTER RECOVERY NODE CAN CRASH. |
|
IV87981 |
A POTENTIAL
SECURITY ISSUE EXISTS |
|
IV88287 |
INACTIVE
LPM MAY FAIL DUE TO MISSING CAPABILITIES |
|
IV88351 |
Timing
related deadlock issue in LPM |
|
IV88688 |
RECREATEVG
-D NEEDS BETTER USAGE DOCUMENTATION. |
|
IV88719 |
DSI
IN SEADD:SEA_VIRT_INPUT_POST_Q |
|
IV88727 |
RULESCFGSET
MAY ADD GARBAGE LINES IN MOTD FILE |
|
IV89148 |
Potential
cluster hang during svCollect. |
|
IV90068 |
PCM SSP data collection
status may not be updated properly |
|
IV90482 |
bos.esagent fails to