VIOS 2.2.5.10 Release Notes

 

Package Information

PACKAGE: Update Release 2.2.5.10
IOSLEVEL: 2.2.5.10

VIOS level is

NIM Master level must be equal to or higher than

Update Release 2.2.5.10

       AIX 6100-09-08 or AIX 7100-04-03

 

 

In June 2015, VIOS introduced the minipack as a new service stream delivery vehicle as well as a change to the VIOS fix level numbering scheme. The VIOS “fix level” (the 4th number) has changed to two digits. For example VIOS 2.2.5.1 has been changed to VIOS 2.2.5.10. Please refer to the VIOS Maintenance Strategy here for more details regarding the change to the VIOS release numbering scheme.

 

General package notes

Be sure to heed all minimum space requirements before installing.  For this version, target at least 900MB available in the ‘/’ directory.

Review the list of fixes included in Update Release 2.2.5.10

To take full advantage of all the functions available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 2.2.5.10.

Microcode or system firmware downloads for Power Systems

The VIOS Update Release 2.2.5.10 includes the IVM code, but it will not be enabled on HMC-managed systems. Update Release 2.2.5.10, like all VIOS Update Releases, can be applied to either HMC-managed or IVM-managed VIOS.

Update Release 2.2.5.10 updates your VIOS partition to ioslevel 2.2.5.10. To determine if Update Release 2.2.5.10 is already installed, run the following command from the VIOS command line.

$ ioslevel

If Update Release 2.2.5.10 is installed, the command output is 2.2.5.10.

 

Known Capabilities and Limitations

The following requirements and limitations apply to Shared Storage Pool (SSP) features and any associated virtual storage enhancements.

Requirements for Shared Storage Pool

  • Platforms: POWER6 and later (includes Blades), IBM PureFlex Systems (Power Compute Nodes only)
  • System requirements per SSP node:
    • Minimum CPU: 1 CPU of guaranteed entitlement
    • Minimum memory: 4GB
    • Storage requirements per SSP cluster (minimum): 1 fiber-channel attached disk for repository, 1 GB
    • At least 1 fiber-channel attached disk for data, 10GB

Limitations for Shared Storage Pool

Software Installation

  • All VIOS nodes must be at version 2.2.1.3 or later
  • When installing updates for VIOS Update Release 2.2.5.10 participating in a Shared Storage Pool, the Shared Storage Pool Services must be stopped on the node being upgraded.
  • In order to take advantage of the new SSP features in 2.2.4.00 (including improvements in the min/max levels), all nodes in the SSP cluster must be at 2.2.4.00.

SSP Configuration

 

Feature

Min

Max

Special*

Number of VIOS Nodes in Cluster

1

16

24

Number of Physical Disks in Pool

1

1024

 

Number of Virtual Disks (LUs) Mappings in Pool

1

8192

 

Number of Client LPARs per VIOS node

1

250

400

Capacity of Physical Disks in Pool

10GB

16TB

 

Storage Capacity of Storage Pool

10GB

512TB

 

Capacity of a Virtual Disk (LU) in Pool

1GB

4TB

 

Number of Repository Disks

1

1

 

Capacity of Repository Disk

512MB

1016GB

 

Number of Client LPARs per Cluster

1

2000

 

*These features have special hardware requirements that must be met:

  • Over 16 VIOS Nodes requires that the SYSTEM (metadata) tier contains only SSD storage.
  • Over 250 Client LPARS per VIOS requires each VIOS have at least 4 CPUs and 8 GB memory.

Other notes:

  • Maximum number of physical volumes that can be added to or replaced from a pool at one time: 64
  • The Shared Storage Pool cluster name must be less than 63 characters long.
  • The Shared Storage Pool pool name must be less than 127 characters long.
  • The maximum supported LU size is 4TB, however, for high I/O workloads it is recommended to use multiple smaller LUs as it will improve performance. For example, using 16 separate 16GB LUs would yield better performance than a single 256GB LU for applications that perform reads and writes to a variety of storage locations concurrently.
  • The size of the /var drive should be greater than or equal to 3GB to ensure proper logging.

Network Configuration

  • Uninterrupted network connectivity is required for operation. i.e. The network interface used for Shared Storage Pool configuration must be on a highly reliable network which is not congested.
  • A Shared Storage Pool configuration can use IPV4 or IPV6, but not a combination of both.
  • A Shared Storage Pool configuration should configure the TCP/IP resolver routine for name resolution to resolve host names locally first, and then use the DNS. For step by step instructions, refer to the TCP/IP name resolution documentation in the IBM Knowledge Center.
  • The forward and reverse lookup should resolve to the IP address/hostname that is used for Shared Storage Pool configuration.
  • It is recommended that the VIOSs that are part of the Shared Storage Pool configuration keep their clocks synchronized.

Storage Configuration

  • Virtual SCSI devices provisioned from the Shared Storage Pool may drive higher CPU utilization than the classic Virtual SCSI devices.
  • Using SCSI reservations (SCSI Reserve/Release and SCSI-3 Reserve) for fencing physical disks in the Shared Storage pool is not supported.
  • SANCOM will not be supported in a Shared Storage Pool environment.

Shared Storage Pool capabilities and limitations

  • On the client LPAR Virtual SCSI disk is the only peripheral device type supported by SSP at this time.
  • When creating Virtual SCSI Adapters for VIOS LPARs, the option "Any client partition can connect" is not supported.
  • VIOSs configured for SSP require that Shared Ethernet Adapter(s) (SEA) be setup for Threaded Mode (the default mode). SEA in Interrupt Mode is not supported within SSP.
  • VIOSs configured for SSP can be used as a Paging Space Partition (PSP), but the storage for the PSP paging spaces must come from logical devices not within a Shared Storage Pool. Using a VIOS SSP logical unit (LU) as an Active Memory Sharing (AMS) paging space or as the suspend/resume file is not supported.

 

Installation Information

 

Pre-installation information and instructions

Please ensure that your rootvg contains at least 30 GB and that there is at least 4GB free space before you attempt to update to Update Release 2.2.5.10. Run the lsvg rootvg command, and then ensure there is enough free space.

Example:

$ lsvg rootvg

VOLUME GROUP:       rootvg                   VG IDENTIFIER:  00f6004600004c000000014306a3db3d

VG STATE:           active                   PP SIZE:        64 megabyte(s)

VG PERMISSION:      read/write               TOTAL PPs:      511 (32704 megabytes)

MAX LVs:            256                      FREE PPs:       64 (4096 megabytes)

LVs:                14                       USED PPs:       447(28608 megabytes)

OPEN LVs:           12                       QUORUM:         2 (Enabled)

TOTAL PVs:          1                        VG DESCRIPTORS: 2

STALE PVs:          0                        STALE PPs:      0

ACTIVE PVs:         1                        AUTO ON:        yes

MAX PPs per VG:     32512                                    

MAX PPs per PV:     1016                     MAX PVs:        32

LTG size (Dynamic): 256 kilobyte(s)          AUTO SYNC:      no

HOT SPARE:          no                       BB POLICY:      relocatable

PV RESTRICTION:     none                     INFINITE RETRY: no

 

Upgrading from VIO version lower than 2.1.0

If you are planning to update a version of VIOS lower than 2.1, you must first migrate your VIOS to VIOS version 2.1.0 using the Migration DVD. After the VIOS is at version 2.1.0, the Upgrade/Fixpack 2.2.5.10 must be applied to bring the VIOS to the latest Fix Pack VIOS 2.2.5.10 level.

Note that with the Update Release 2.2.5.10, a single boot alternative to this multiple step process is available to NIM users. NIM users can update by creating a single, merged lpp_source that combines the contents of the Migration DVD with the contents of this Update Release 2.2.5.10.

A single, merged lpp_source is not supported for a VIOS that uses SDDPCM. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location:

SDD and SDDPCM migration procedures when migrating VIOS from version 1.x to version 2.x

After the VIOS migration is complete, from 1.X to 2.X, you must set the Processor Folding, described here under Migration DVD:

            Instructions to disable Processor Folding are detailed at the link below.

            See the “Migration DVD” section:

            Virtual I/O Server support for Power Systems

 

Upgrading from VIO version 2.1.0 and above

The current level of VIOS must be between 2.2.1.1 and 2.2.4.x, you can put 2.2.5.10 in a location and do the update using updateios command

 

Before installing the VIOS Update Release 2.2.5.10

The update could fail if there is a loaded media repository.

Checking for a loaded media repository

To check for a loaded media repository, and then unload it, follow these steps.

  1. To check for loaded images, run the following command:
    $ lsvopt
    The Media column lists any loaded media.
  2. To unload media images, run the following commands on all Virtual Target Devices that have loaded images.
    $ unloadopt -vtd <file-backed_virtual_optical_device >
  3. To verify that all media are unloaded, run the following command again.
    $ lsvopt
    The command output should show No Media for all VTDs.

 

Migrate Shared Storage Pool Configuration

The Virtual I/O Server (VIOS) Version 2.2.2.1 or later, supports rolling updates for SSP clusters.  The VIOS can be updated to Update Release 2.2.5.10 using rolling updates

If your current VIOS is running with Shared Storage Pool from 2.2.1.1 or 2.2.1.3, the following information applies:

A cluster that is created and configured on VIOS Version 2.2.1.1 or 2.2.1.3 must be migrated to version 2.2.1.4 or 2.2.1.5 prior to utilizing rolling updates. This allows the user to keep their shared storage pool devices. When VIOS version is equal or greater than 2.2.1.4 and less than 2.2.5.10, the user needs to download 2.2.5.10 update images into a directory, then update the VIOS to Update Release 2.2.5.10 using rolling updates.

If your current VIOS is configured with Shared Storage Pool from 2.2.1.4 or later, the following information applies:

The rolling updates enhancement allows the user to apply Update Release 2.2.5.10 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.

To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:

  • All VIOS logical partitions must have VIOS Update Release version 2.2.1.4 or later installed. After the update, you can verify that the logical partitions have the new level of software installed by typing the cluster -status -verbose command from the VIOS command line. In the Node Upgrade Status field, if the status of the VIOS logical partition is displayed as UP_LEVEL, the software level in the logical partition is higher than the software level in the cluster. If the status is displayed as ON_LEVEL, the software level in the logical partition and the cluster is the same.
  • All VIOS logical partitions must be running. If any VIOS logical partition in the cluster is not running, the cluster cannot be upgraded to use the new SSP capabilities.

The VIOS SSP software monitors node status and will automatically upgrade the cluster to make use of the new capabilities when all the nodes in the cluster have been updated, “cluster –status –verbose” reports “ON_LEVEL”.

 

Installing the Update Release

There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link. To verify the VIOS update files, follow these steps:

$ oem_setup_env
Create a link to openssl
# ln -s /usr/bin/openssl /usr/ios/utils/openssl
Verify the link to openssl was created
# ls –alL /usr/bin/openssl /usr/ios/utils/openssl

Both files should display similar owner and size
# exit

Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.

If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.

Note: While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.

If your current level is between 2.2.1.1 and 2.2.2.1, you can directly apply 2.2.5.10 updates. This fixes an update problem with the builddate on bos.alt_disk_install.boot_images fileset.

If your current level is 2.2.2.1, 2.2.2.2, 2.2.2.3 or 2.2.3.1, you need to run “updateios” command twice to get bos.alt_disk_install.boot_images fileset update problem fixed.

Run the following command after the step of “$ updateios -accept -install -dev <directory_name>” completes.

$updateios -accept -dev <directory_name>

 

 

 

 

Depending on the VIOs level one or more of the LPPs below may be reported as "Missing Requisites", and they may be ignored.

 

MISSING REQUISITES:


    X11.loc.fr_FR.base.lib 4.3.0.0           

    bos.INed 6.1.6.0                            

    bos.loc.pc.Ja_JP 6.1.0.0                

    bos.loc.utf.EN_US 6.1.0.0            

    bos.mls.rte 6.1.x.x                         

    bos.mls.rte 6.1.9.200                      

    bos.svprint.rte 6.1.9.200                

# Base Level Fileset

# Base Level Fileset

# Base Level Fileset

# Base Level Fileset

# Base Level Fileset

# Base Level Fileset or #Fileset Update

# Fileset Update


Applying updates

WARNING: If the target node to be updated is part of a redundant VIOS pair, ensure that the VIOS partner node is fully operational before beginning to update the target node. NOTE that for VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.

The current level of the VIOS must be 2.2.2.1 or later if you use Share Storage Pool

  1. Log in to the VIOS as the user padmin.
  2. If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here..
  3. If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.
    $ clstartstop -stop -n <cluster_name> -m <hostname>
  4. To apply updates from a directory on your local hard disk, follow the steps:

·       Create a directory on the Virtual I/O Server.
$ mkdir <directory_name>

·       Using ftp, transfer the update file(s) to the directory you created.

To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:

·       Mount the remote directory onto the Virtual I/O Server.
$ mount remote_machine_name:directory /mnt

 

The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, following the steps:

 

·       Place the CD-ROM into the drive assigned to VIOS.

  1. Commit previous updates by running the updateios command
    $ updateios -commit
  2. Verify the updates files that were copied. This step can only be preformed if the link to openssl was created.
    $ cp <directory_path>/ck_sum.bff /home/padmin
    $ chmod 755 /home/padmin/ck_sum.bff
    $ ck_sum.bff <directory_path>
    If there are missing updates or incomplete downloads, an error message is displayed.
  3. Apply the update by running the updateios command
    $ updateios -accept -install -dev <directory_name>
  4. To load all changes, reboot the VIOS as user padmin .
    $ shutdown -restart

Note: If “shutdown -restart” command failed, please run swrole – PAdmin” in order for padmin to set authorization and establish access to the “shutdown” command properly.

  1. If cluster services were stopped in step 3, restart cluster services.
    $ clstartstop -start -n <cluster_name> -m <hostname>
  2. Verify that the update was successful by checking the results of the updateios command and by running the ioslevel command, which should indicate that the ioslevel is now 2.2.5.10.
    $ioslevel

 

Performing the necessary tasks after installation

Checking for an incomplete installation caused by a loaded media repository

After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.

Check the Media Repository by running this command:
$ lsrep

If the command reports: "Unable to retrieve repository date due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.

Running the lsvopt command should show the media images.

Recovering from an incomplete installation caused by a loaded media repository

To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:

  1. Unload any media images
    $ unloadopt -vtd <file-backed_virtual_optical_device>
  2. Reinstall the ios.cli.rte fileset by running the following commands.
    To escape the restricted shell:
    $ oem_setup_env
    To install the failed fileset:
    # installp -Or -agX ios.cli.rte -d <device/directory>
    To return to the restricted shell:
    # exit
  3. Restart the VIOS.
    $ shutdown -restart
  4. Verify that the Media Repository is operational by running this command:
    $ lsrep

 

Additional information

NIM backup, install and update information

Use of NIM to back up, install and update the VIOS is supported.

For further assistance, on the back up and install using NIM refer to the NIM documentation.

Note: For install always create the SPOT resource directly from the VIOS mksysb image.

          Do NOT update the SPOT from an LPP_SOURCE.

 

Use of NIM to update the VIOS is supported as follows:

 

Ensure that the NIM Master is at the appropriate level to support the VIOS image. Refer to the above table in the "Package information" section.

On the NIM Master use the operation "updateios" to update the VIO Server.

            Sample:  "nim -o updateios -a lpp_source=lpp_source1 ... ... ..."

             For further assistance, refer to the NIM documentation.

 

On the NIM Master use the operation "alt_disk_install" to update an alternate disk copy of the VIO Server.

            Sample: “nim -o alt_disk_install -a source=rootvg

                            -a disk=target_disk -a fix_bundle=(Value)  … … …”

For further assistance, refer to the NIM documentation.

 

If NIM is not used to update the VIOS,  only the updateios or the alt_root_vg command from the padmin shell can be used to update the VIOS.

 

Installing the latest version of Tivoli TSM

This release of VIOS contains several enhancements. These enhancements are in the area of POWER virtualization. The following list provides the features of each element by product area.

Note: Version 6.1.0, the previous version of Tivoli TSM, is still shipped and installed from the VIOS installation DVD.

Tivoli TSM version 6.2.2

The Tivoli TSM filesets are now being shipped on the VIOS Expansion Pack, with the required GSKit8 libraries.

The following are sample installation instructions for the new Tivoli TSM filesets:

  1. Insert the VIOS Expansion DVD into the DVD drive that is assigned to the VIOS partition.
  2. List Contents of the VIOS Expansion DVD
    $ updateios -list -dev /dev/cd0
    Fileset Name
    GSKit8.gskcrypt32.ppc.rte 8.0.14.7
    GSKit8.gskcrypt64.ppc.rte 8.0.14.7
    GSKit8.gskssl32.ppc.rte 8.0.14.7
    GSKit8.gskssl64.ppc.rte 8.0.14.7
    ..
    tivoli.tsm.client.api.32bit 6.2.2.0 tivoli.tsm.client.api.64bit 6.2.2.0
    ..
  3. Install Tivoli TSM filesets
    $ updateios -fs tivoli.tsm.client.api.32bit -dev /dev/cd0
    NOTE: Any prerequisite filesets will be pulled in from the Expansion DVD, including for TSM the GSKit8.gskcrypt fileset.
  4. If needed, install additional TSM filesets
    $ updateios -fs tivoli.tsm.client.ba.32bit -dev /dev/cd0
  5. Verify TSM installed by listing software installed.
    $ lssw
    Sample output:
    ..
    tivoli.tsm.client.api.32bit 6.2.2.0 C F TSM Client - Application Programming Interface

 

Fixes included in this release

 

The list of fixes in 2.2.5.10

 

APAR

Description

IV61308

HANG IN ELXENT_BUGOUT

IV65101

CAA MKWPAR -S CREATES WPAR WITH SPINNING CLCOMD

IV67228

SYSTEM CRASH DUE TO RECURSIVE LOCK IN FC5287 DRIVER

IV67308

VERY SLOW NETWORK THROUGHPUT FROM VIOC

IV69355

SEA LARGESEND CAN CAUSE TCP BAD HEADER OFFSET ON VIRTUAL CLIENT

IV69897

AIX /USR/SYSV/BIN/DF COMMAND REPORTS INCORRECT VALUES

IV70553

SAS CD DRIVE MAPPINGS CHANGED WHEN VIOS REBOOTED

IV70843

AIXPERT MAY ADD WRITE PERMISSION TO PROGRAMS

IV70899

FC1763/FC5899 supported port may become unresponsive

IV71204

rootcronjobck fails to handle symlink

IV71882

Invalidate on vid matched pvid of non-default trunk adapter.

IV71906

LVS AND VGS GET DISPLAYED WHEN THEY SHOULD BE HIDDEN.

IV72007

INCORRECT READ MAY OCCUR DURING JOINVG

IV72025

Assert in emfsc_free_cmd_elem

IV72133

caa: no gossip transmission on boot can lead to split-brain

IV72147

CFGIPSEC NOT PROPERLY HANDLING COMMENTS IN NEXTBOOT FILE

IV72562

SFW SFWCOM APPEARS UP TO CAA WHEN IT IS NOT FUNCTIONAL

IV72893

CLCOMD CAN USE TOO MUCH CPU WHEN AHAFS NOT ACCESSIBLE

IV73000

INCORRECT DETAIL IN VIOD_ALERT_EVENT IF CM DB FS CANNOT BE CHECK

IV73642

LSDEV -TYPE ENT4SEA EXCLUDES ROCE ADAPTER

IV73705

usrck does not catch non-executable shell

IV73716

partitions with more than 87,380 LMBs may crash

IV73758

EXECUTING STOPSRC -G IKE CAN HANG TMD

IV73765

alert -list option should list alerts of all tiers.

IV73767

Adapter in unknown state with nddctl -r

IV73768

EXTENDVG OF CONC VG MAY FORCE THE VG OFFLINE ON REMOTE NODE

IV73769

system crash in hd_reduce(), lvm layer

IV73770

joinvg in concurrent VG may put disks in missing

IV73838

caa: inactive node fails to generate remote node_up ahafs event

IV73951

I/O may hung during SCSI ACA Error Condition.

IV73952

cleanup SRC VIOS mappings after client lpar is remote restarted.

IV73954

system crash with livedump

IV73955

Unclear script callout errors

IV73976

A potential security issue exists CVE-2014-3566

IV73989

Node cle_globid range incorrect

IV73994

incorrect VPD information for Integrated ethernet adapter

IV74097

Slow NIM install/telnet/tcp connections

IV74184

The second port on Travis3-EN doesn't work

IV74329

CVE-2015-0261 and CVE-2015-2154 tcpdump vulnerablity fix

IV74484

ENTSTAT ON SEA FAILS WITH ENTSTAT_MODE ENVIRONEMT VARIABLE

IV74606

ALT_DISK_COPY ON 4K DISK TRIGGERS LVM_IO_FAIL

IV74650

caa: repository disk replacement may fail

IV74726

Etherchannel not recovering after port reset

IV74927

A potential security issue exists CVE-2015-2808

IV74946

clconfd lvm conflict with chrepos

IV75001

MIGRATEPV FAILURE MAY CAUSE IO HANG IN CONCURRENT VG

IV75057

rmvdev fails with an LU backed vtd.

IV75100

Restore seems to hang.

IV75102

SSP Lu's mapping goes missing after remote restart

IV75273

LSLDAP KEEPS ON FAILLING WHEN LDAP SERVER CLOSES CONNECTION

IV75290

Multiple client_partition entries cause mapping issues.

IV75364

CAA: UNEXPECTED START_NODE BY PEER NODE LEADS TO AST PANIC

IV75387

CAA: SYSTEM WILL CRASH IF GOSSIP PACKET HAS ID = 0

IV75388

updateios gives incorrect error codes/messages for some options

IV75480

LPM validation fails if some port bounce happens on SAN

IV75495

CODEGCHECK MIGHT FAIL WITH FALSE ERROR, DISPLAYING SCRIPTED

IV75538

caa: defined pv that matches repo pvid causes mkcluster to fail

IV75589

SYSTEM CRASHES IN ICMCLOSEQP1

IV75591

Resume can fail with HMC code HSCLA27F after validation pass.

IV75627

Cluster create could fail

IV75685

LPM can fail with HMC to MSP connection timed out error

IV75719

FCSTAT -N WWNXXXX FCS0 RETURNS 0 FOR FCSTAT OUTPUT

IV75738

LSSEC PERFORMANCE SUFFERS WHEN EFS IS ENABLED

IV75879

AIXPERT: RELATIVE CRON JOB SPECIFICATIONS MAY FAIL

IV75880

AIXPERT: FAILS TO HANDLE PARENT DIRECTORIES WITH ROOTCRNJOBCK

IV75883

DST with SRIOV dedicated failed in Stage 3

IV76033

Some SSP VTDs are not restored during cluster restore

IV76130

Invalid repository reserve policy not detected on remote nodes

IV76151

IKED LOOPS AND CAUSES CPU LOAD WHEN 0-BYTE DATAGRAM IS PRESENT

IV76158

SYSTEM CRASH AFTER RENDEV ON FCS ADAPTER

IV76194

VLAN ADAPTER ON PCIE2 4-PORT ADAPTER(10GBE SFP+) DROPS PACKETS

IV76204

ISCSI TOE SENDING IO TO WRONG TARGET

IV76214

VIO Change Mgmt daemon can core dump

IV76216

LUN discovery may fail during cfgmgr

IV76243

ETHERCHANNEL WITH CT3 ADAPTER MAY HANG

IV76254

Unable to start pool after a failed FG operation

IV76256

Unlock adapter is not required when lock did not happen earlier

IV76359

Do not remove adapter if suspend info is not updated

IV76508

EFSENABLE -D WRT LDAP OPERATION FAILS IN SOME SCENARIOS

IV76512

Packets with old MAC are received after changing MAC

IV76529

System crash while running hxecom with modified ent attributes

IV76530

VMLibrary size may be listed as zero

IV76538

SCTP heartbeats are not getting sent within RTO of the path

IV76591

0514-061 CANNOT FIND A CHILD DEVICE ERRORS ON FC ADAPTERS

IV76723

CAA UNICAST CLU: DMS ON LAST NODE DUE TO INCORRECT DPCOM STATE

IV76806

LSGROUP INCORRECTLY CACHES LDAP USER INFORMATION

IV76817

LPM validation or some VIOS function may give ODM lock errors

IV76821

'devrsrv' command to force clear SCSI-2 reserve on a vSCSI fails

IV77175

CAA: MERGE FAILURE DUE TO STALE JOIN_PENDING FLAG.

IV77179

viosecure command fails during rule failure with file option

IV77182

cluster Restore may fail in 1 node cluster with PowerVC

IV77183

System crash during adapter EEH recovery.

IV77471

Callback with NDD_LS_DOWN when EEH detected

IV77472

lnc2ent kdb command fails due to corrupted command table entry.

IV77475

ADD FOR POWERVC RESERVE_LOCK POLICY USING EMC 5.3.0.6 OR OLDER

IV77506

CACHEFS CRASHES IN CFIND()

IV77509

ABEND IN RESET_DECV

IV77510

SYSTEM CRASH IN REMOVING THE SEA ADAPTER BY RMDEV COMMAND

IV77522

Disks belonging to cluster are shown as free.

IV77529

DISK NORMAL OPEN FAILS WITH EACCES

IV77670

DIAG RETURNED 2E41-103: CHECKSUM VERIFICATION TEST FAILED

IV77687

ALLOW FC ATTRIBUTES TO BE SHOWN AND CHANGEABLE VIA SMIT

IV77744

Removing SEA device causes hang, SEA threads hang

IV77964

CAA: CHREPOS -C INCORRECTLY SAVES NODE_LOCAL VALUE TO REPO DISK

IV78144

cluster -status command does not always show pool status

IV78187

DSI IN ENTCORE_TX_SEND IN MLXENTDD

IV78360

LDAP USER HAS ADMCHG SET AFTER CHANGING OWN PASSWORD

IV78412

FAILURE OF VIOSBR (VIRTUALCFG) DOESN'T REMOVE WORKING FILES

IV78416

SECLDAPCLNTD INVALID CACHE ATTRIBUTE

IV78419

FC5899 IS MISSING SMIT PANEL FOR CHANGING MEDIA SPEED.

IV78420

NPIV adapter becomes unresponsive

IV78422

Repository Disk is shown as free when it is actually in use

IV78425

ROOTCRNJOBCK FAILS TO HANDLE RELATIVE SYMLINKS & SYMLINK CHAINS

IV78444

LOOPMOUNT COMMAND MAY FAIL FOR READ-ONLY NFS MOUNT

IV78453

IMPROVED DRIVER'S FAIRNESS ALGORITHM TO AVOID I/O STARVATION

IV78454

IMPROVED DRIVER'S FAIRNESS LOGIC TO AVOID I/O STARVATION

IV78502

LOOPING IN EFC_FREE_LOGIN_TBLE

IV78549

CRASH DUE TO BRKPOINT IN GXIB_RAS_REGISTER CALL DURING BOOT

IV78576

CRFS -A QUOTA=NO SHOULD HAVE FAILED DUE TO INVALID ATTRIBUTE

IV78682

Disk validation for LPM of NPIV client fails

IV78830

NPIV CLIENT LPAR REBOOT CAN HANG THE VIOS

IV78884

ALT_DISK_COPY MAY FAIL WHEN MOUNTING FILESYSTEMS

IV78895

NPIV Migration failed with Function npiv_phys_spt tried to

IV78897

LU-level validation for LPM fails with IBM i or Linux clients

IV78899

System crash in entcore_link_change_nic_callback()

IV78900

Removing certain virtual devices incorrectly fails.

IV79060

ABEND IN NMENT_FREE_RX

IV79066

CLMIGCHECK GIVES WARNING ON SYSLOG.CONF UPDATE

IV79067

CLMIGCHECK GIVES RESERVE ERROR ON REPOSITORY DISK

IV79069

VALID AIX LEVELS MIGHT BE INCORRECTLY IDENTIFIED AS INVALID.

IV79073

MISSING INFORMATION FROM CLMIGCHECK ERROR MESSAGE

IV79074

CLMIGCHECK FAILS IF NETSVC.CONF CONTAINS COMMENTED HOSTS LINES

IV79281

CLMIGCHECK MIGHT FAIL ON CLUSTERS WITH MORE THAN TWO NODES.

IV79303

IO.TEM CAN CRASH DURING THE PROCESSING OF FAILED ASYNCHRONOUS

IV79469

LU count listed in tier list output is incorrect.

IV79471

Some SSP VTDs missing after restore operation

IV79516

VKE_INFO QUEUE FULL ERROR DETAIL MESSAGE

IV79634

FAILED PATH ON A CLOSED DISK MAY NOT RECOVER AFTER DISK REOPEN

IV79658

LEVEL.OT MIGRATIONS FAIL IF ALL NODES NOT AT THE SAME CAA

IV79710

NIMADM FAILS WHEN MASTER IS BOOTED FROM BOS_HD5

IV79729

CLASS 3 NAMESERVER QUERY ODM SUPPORT FOR LEGACY FC ADAPTER

IV79874

SEA CONTROL CHANNEL & TRUNK VIRTUAL ADAPTER SHARE PVID CRASH

IV79991

FAST_FAIL MAY NOT WORK WHEN THE IMM_GID_PN ENABLED

IV80113

viosbr overwrites backups with frequency option.

IV80127

NIB ETHERCHANNEL WITH SR-IOV VF PORT PROBLEM

IV80151

SLOW HA EVENT PROCESSING IN LINKED CLUSTER DUE TCPSOCK RESETS

IV80435

TRUSTCHK -U OUTPUT INVALID ATTRIBUTES FOR HARDLINKS & SYMLINKS

IV80569

MUSENTDD'S RECEIVE PATH HANGS WHEN IT RECEVIES CERTAIN SIZE PKT

IV80598

System crash after cachefs forced unmount

IV80689

LNCENTDD: MULTICAST ADDRS LOST WHEN PROMISCUOUS MODE TURNED OFF

IV80732

ISAKMPD CORE DUMPED IN SPI_PROTO DESTRUCTOR

IV80871

Race in lncentdd/lnc2entdd driver may make adapter unusable.

IV81016

When the catalog path is invalid artex commands coredump.

IV81022

ISAKMPD CORE DUMP AT COPY_REPL

IV81023

NETSTAT & ENTSTAT FOR ETHERCHANNELS WITH SRIOV DO NOT SHOW MAC

IV81024

MKFS -V JFS2 -O LOG=INLINE /DEV/LOOP0 WITH IV79296 INSTALLED

IV81223

HMC reports that VIOS is busy and not responding to queries

IV81241

MELLANOX V2 DRIVER LOGS LINK UP AND LINK DOWN DURING REBOOT

IV81297

VIO CLIENT CRASHES IN DISK DRIVER DURING LPM WITH GPFS AND PR SH

IV81352

VM deploy fails when using NIC adapters

IV81454

DSI IN RRHBA_QUERY_NIC

IV81462

DF AND LSFS MAY LIST THE WRONG FILESYSTEM

IV81739

LPM: MIGMGR(FIND_DEVICES -T VETH) RC=8 ON DESTINATION VIOS

IV81756

VIOS may crash after using SSP image management in IBM Director

IV81820

CM ATTRIBUTE: MISSING MPIOALGORITHM FOR POWERPATH PVS

IV81839

Virtual tape devices do not configure after upgrading VIOS

IV81840

DEVICE IPSEC_V4 MAY COME UP DEFINED AT BOOT

IV81854

Some objects may be missing in list presented to HMC

IV81936

May lose access to one or more NPIV disks

IV81937

Segfault may occur in ioscli vg or lv related commands.

IV81967

UPDATEIOS:REMOVING INSTALLED EFIX FAILS DUE TO GARBAGE CHARACTER

IV82022

LU -RESIZE NOT RECOGNIZED ON CLIENT AND SCF LOCK ERROR

IV82080

SEGMENTATION FAULT IN RULESCFGSET IF MOTD BIGGER THAN 1024 CHARS

IV82145

IPREPORT DOES NOT DISPLAY TCP OPTION 14 (TCPOPT_ALTCKSUM)

IV82194

CRASH DURING VIOENT CALLBACK WHEN USED WITH ETHERCHANNEL

IV82195

SR-IOV TX_TIMEOUT DEFAULTS TO 30 SECONDS

IV82197

LPM-ED CLIENTS TEMPORARILY LOOSE CONNECTIVTY DUE TO RARPS.

IV82449

VIRTUAL ETHERNET ADAPTER DRIVER MAY GOES INTO DEAD STATE.

IV82461

VIOS may rarely crash during LUN-level validation for LPM

IV82463

Adapters using lncentdd driver may log EEH as permanent Error

IV82577

UNMIRRORVG ROOTVG MAY HANG WITH FW-ASSISTED DUMP & HD6

IV82579

SLOW HA EVENT PROCESSING IN LINKED CLUSTER DUE TCPSOCK RESETS

IV82596

SYN NOT RECEIVED WHEN VEA CLIENT TURN OFF CHECKSUM OFFLOAD

IV82627

CAA(MULTICAST): A NODE MAY NOT SEE A REBOOTED NODE AS UP

IV82694

VIO Server using 10 Gb PCIe adapters and large_send may crash

IV82728

SECONDARY GROUP NOT DETERMINED FOR OLDER NETIQ LDAP SERVERS

IV82752

PACKET ADJUSTED MULTIPLE TIMES BY RRHBADD DRIVER

IV82795

VIOS CRASH WHEN CREATING SEA IN LOW MEMORY CONDITION

IV82983

viosbr -restore not restoring other nodes except initiator node

IV83078

VIOS may crash when doing LUN-level validation for LPM

IV83079

trustchk error on /var/adm/cron/log after migration

IV83100

Handle pv backed virtual target devices during suspend operation

IV83121

After viosecure -undo, viosecure -view reports error

IV83143

I/O HANG IN EFC_FREE_LOGIN_TBLE

IV83212

HOSTNAME ISSUES PREVENT NODE FROM JOINING THE CAA CLUSTER

IV83291

NPIV client hang when cancel command fails

IV83544

TRUSTCHK -U FAILS FOR ALLOW_OWNER ALLOW_GROUP ALLOW_ALL

IV83615

ROLLING UPGRADE FROM DBV3 TO V4 FAILS

IV83637

DRW_LOCK_WRITE() BLOCKING READ THREADS CAUSE HANG.

IV83875

SECLDAPCLNTD MAY FAIL TO HANDLE LONG PASSWORD HASH STRINGS

IV84242

VM validation fails if nondisk type LU configured to NPIV client

IV84341

WRONG UDP FILTERS ADDED BY AIXPERT IPSECSHUNPORTS

IV84449

TCBCK -Y ALL IS RUN AT FIRSTBOOT FROM ALTERNATE DISK IN TCB ENV

IV84470

CRASH DUE TO POSSIBLE MEMORY LEAK IN CAA

IV84478

MULTIPLE DUPLICATE PDAT ODM ENTRIES FOR MPIOAPDISK

IV84555

MAC/VLAN ACL status incorrectly displayed when PVID enabled.

IV84636

BOOTPD DOESN'T FIND ROUTE WITH MANY NETWORK INTERFACES IN USE

IV84649

LPM fails when disk's unique_id has special characters

IV84661

Removing interface,when upgrading FW.Move hang state for FC#EN0H

IV84677

CACHE METHOD DOESN'T SET PROD FLAG CORRECTLY.

IV84704

LARGE RECEIVE ON VIOS IS SLOW WHEN VIO CLIENT HAS CHKSUM OFF

IV84767

FAILOVER HAPPENS ON 802.3AD ETHERCHANNEL WHILE REBOOT

IV84769

PANIC IN TSTART VIA SEAHA_PROCESS_DSCV_INIT

IV84776

NODE CRASHED

IV84833

System crash issuing slot reset after returning EEH Suspend busy

IV84889

CAA UNUSABLE NET_ADDR ON REPOSITORY DISK AFTER CHANGE BOOT IP

IV84953

CM daemon runs out of memory and thus restarts.

IV84985

EEH Resume failure can cause restart to set invalid device state

IV85080

Crash due to race condition of between DEAD and Close

IV85145

CONSTANT DISK_ERR4 ERRORS FOR INTERNAL SCSI DISKS IF HEALTH CHEC

IV85215

RDMAcore returns error if suspend is called more than once.

IV85255

ADDING AUDIT CONFIG FULLPATH OPTION

IV85311

Promiscuous or All mcast flags still shown as set after a close

IV85393

system crash running get_adapter with trace level >= 5

IV85395

alt_disk_mksysb hangs without the absolute path to device

IV85423

MOUNT MAY FAIL REPORTING MEDIA IS NOT FORMATTED

IV85460

ABEND_TRAP FROM CLOCK

IV85508

caa: core dump if netmon.cf entries are defined

IV85593

NFS3 OPEN FAILURE AFTER NFS3 OPEN WITH O_DIRECT AND O_CIO FAILS

IV85670

VARYONVG HANG IN SCSIDISK_CLOSE() DURING BOOT

IV85676

Repos DOWN event on create led to crash

IV85884

EEH Exit after performing Hot/Fundamental reset after FW update

IV85886

AIXPERT PREREQS ARE NOT MAINTAINED AFTER APPLYING RULES

IV85888

caa: clcomd fails to handle local internal bound ip address

IV85891

DSI CRASH IN VIOENT_OUTPUT

IV85895

ECH_CANNOT_FAILOVER ERROR WHEN REBOOTING

IV86129

Fix CVE-2015-7575 in imap,pop3

IV86237

Possible race condition between ctrc suspend and trace operation

IV86408

VIOS fails with adapter in use message during LPM

IV86523

SYSTEM MAY HANG WHEN UPGRADING OR REMOVING BOS.RTE.SECURITY

IV86535

system crash while using adapter with FC#EN0S and EN0W

IV86538

SYNCLVODM IS SLOW WHEN THERE ARE MANY DISKS CONFIGURED

IV86577

System crash due to stack overflow when errlogging on slih path

IV86666

mkvopt command allows vopt device names with special characters

IV86678

PACKETS ARE SEEN TWICE IN IPTRACE

IV86679

parallel importpv and reboot fails the importpv operation.

IV86684

handle large image file copies

IV86792

Removal of more than one node from a cluster was giving error

IV86794

Rolling Upgrade does not finish

IV86861

ERROR MESSAGE DURING REPLACEPV NOT RELEVANT

IV87015

clmigcheck fails to find any shared disks

IV87020

VM deploy fails with VIOS_VSCSI_HOST err (relative port id=0)

IV87053

IPTRACE -L DOES NOT ROTATE LOGFILE IF LOGSIZE MORE THAN 2GB

IV87134

VIOS crash in target_cdt_add

IV87309

CRASH IN XHCI_OPEN WHEN ACCESSING /DEV/USBHC0

IV87315

CAA CLCONFD CORE PTH_USCHED._USCHED_DISPATCH_FRONT._CHK_RESTART

IV87496

The validation fails, while migrating the client partitition

IV87670

IMPROVE HANDLING OF UNDETERMINED DISK ERRORS IN MPIO CONFIGURATI

IV87701

Restore fails for the max_transfer size of the hdisks.

IV87704

LPM will not start with a VASI Open error

IV87734

CLUSTER HEARTBEAT SETTINGS SMIT MENU MAY SHOW VALUE AS ZERO

IV87738

cluster backup through viosbr command gives segmentation fault.

IV87742

Do not use FC port if all NPIV ports are in use

IV87743

Displaying cluster status during cluster node out of network

IV87775

IMPROVE HANDLING OF ABORTED COMMANDS

IV87913

SYSTEM CRASH WITH NPIV_VALIDATE_DO_PORT_LOGIN

IV87957

FC5899 ENTSTAT PRINTS 1818495488 FOR BAD PACKET COUNT IN NON-C

IV87958

DURING FCS ADAPTER RECOVERY NODE CAN CRASH.

IV87981

A POTENTIAL SECURITY ISSUE EXISTS

IV88287

INACTIVE LPM MAY FAIL DUE TO MISSING CAPABILITIES

IV88351

Timing related deadlock issue in LPM

IV88688

RECREATEVG -D NEEDS BETTER USAGE DOCUMENTATION.

IV88719

DSI IN SEADD:SEA_VIRT_INPUT_POST_Q

IV88727

RULESCFGSET MAY ADD GARBAGE LINES IN MOTD FILE

IV89148

Potential cluster hang during svCollect.

IV90068

PCM SSP data collection status may not be updated properly

IV90482

bos.esagent fails to update during VIOS 2.2.5.10 SP install