PACKAGE: Update Release 4.1.2.10
IOSLEVEL: 4.1.2.10
|
VIOS level is |
The AIX level of the NIM Master
level must be equal to or higher than |
|
Update Release 4.1.2.10 |
AIX
7300-04 |
Be sure to heed all minimum
space requirements before installing.
Review the list of fixes included in
Update Release 4.1.2.10
To take full advantage of all
the functions available in the VIOS, it may be necessary to be at the latest
system firmware level. If a system firmware update is necessary, it is
recommended that the firmware be updated before you update the VIOS to Update
Release 4.1.2.10.
Microcode
or system firmware downloads for Power Systems
If the VIOS being updated has filesets installed from the VIOS Expansion Pack, be sure to
update those filesets with the latest VIOS Expansion
Pack if updates are available.
Update Release 4.1.2.10
updates your VIOS partition to ioslevel 4.1.2.10.
To determine if Update Release 4.1.2.10
is already installed, run the following command from the VIOS command line.
$ ioslevel
If Update Release 4.1.2.10
is installed, the command output is 4.1.2.10.
Upgrade to VIOS 4.1.x
· Existing VIOS systems with supported versions of
3.1.x.y can be upgraded to VIOS version 4.1.2.10 (DVD image) or 4.1.2.10 (Flash
image) using viosupgrade tool. Although it is recommended to be on VIOS 3.1.4.30 or later SP level
before upgrading to VIOS 4.1.x level.
·
VIOS systems with
SSP configuration must be on 3.1.3.x or later level before upgrading to 4.1.x
level or adding 4.1.x nodes into cluster.
· If Active Memory Sharing (AMS) is configured on the VIOS, it should be
un-configured before upgrading. You may refer the link on how to un-configure.
· Before upgrading, you may read the viosupgrade
blog in PowerVM Community which explains various scenarios.
Note 1: In an SSP cluster environment, if you're upgrading from version
3.1.4.50 or later, you must upgrade only to version 4.1.1.00 or later.
Additionally, ensure that all nodes in the cluster are running version 3.1.4.50
or later before proceeding with the upgrade.
Note 2: Using updateios command, vios can be updated from 4.1.1.00 or later to 4.1.2.10 level. However, if you use upgrade method using viosupgrade command, you may encounter a boot issue while booting with the new rootvg disk if it gets into incorrect combination of attributes reserve_policy and algorithm. Run below command on the SCSI disks to avoid the problem.
$ chdev
-dev hdiskX -attr reserve_policy=single_path
algorithm=fail_over
For Customers using NVMe Over Fabric (SAN) as their Boot Disk
Booting
from NVMeoF disk may fail if certain fabric errors
are returned, hence a boot disk set up with multiple paths is
recommended. In case there is a failure to boot, the boot process may
continue if you exit from the SMS menu. Another potential workaround is to discover
boot LUNs from the SMS menu and then retry boot.
Note
If the
Virtual I/O servers are configured with “32Gb PCIe4 2-Port FC Adapter, Feature Code(s)
EN1J and EN1K”, then the requirement is to update the adapter microcode level
to 7710812214105106.070120 before
updating the Virtual I/O server to 4.1.2.10 level.
Please refer to the release notes at this link
HIPER issue: If you are upgrading to VIOS 3.1.4.50 or 4.1.1.x or above version please consult this link
This release of VIOS contains several enhancements in PowerVM virtualization area.
Live
Partition Mobility (LPM) enhancements
You can bypass the port-level validation for the N_Port
ID Virtualization (NPIV) devices for logical partition (lpar)
migration with Linux or IBM i operating systems. This
action successfully completes the LPM operation if all the Logical Unit Numbers
(LUN) are available across both the source and destination VIOS instances,
irrespective of the storage ports through which they are accessible.
For more information, see Specifying the attributes for a
partition mobility operation by using the VIOS.
VIOS command enhancements
The following enhancements are made to the commands:
1. Run the setsecattr command to add vios.file.read or vios.file.write authorizations
to the required system configuration file.
Example:
setsecattr
-f writeauths=vios.file.write
/etc/cronlog.conf
2. Run the setkst command to apply the
authorization changes to the system configuration file.
3. Run the pvi command to access and edit the
system configuration file.
Virtual
Fibre Channel (VFC) adapter enhancements
The following enhancements are made to the VFC adapters:
For more information,
see the latest AIX and IBM i documentation.
Shared
Storage Pool (SSP) enhancements
The following
enhancements are made to the shared storage pool:
Shared
Ethernet Adapter (SEA) accounting enhancements
The SEA accounting functionality monitors the network traffic to and
from the client virtual Ethernet adapters it serves. Enhancements have been made
in the functionality to reduce the overhead in SEA accounting. This improves
the overall SEA performance.
Please check this link
for supported hardware.
The following requirements and limitations apply to
Shared Storage Pool (SSP) features and any associated virtual storage
enhancements.
Software Installation
SSP Configuration
|
Feature |
Min |
Max |
|
Number of VIOS
Nodes in Cluster |
1 |
16* |
|
Number of
Physical Disks in Pool |
1 |
1024 |
|
Number of
Virtual Disks (LUs) Mappings in Pool |
1 |
8192 |
|
Number of
Client LPARs per VIOS node |
1 |
250* |
|
Capacity
of Physical Disks in Pool |
10GB |
16TB |
|
Storage
Capacity of Storage Pool |
10GB |
512TB |
|
Capacity
of a Virtual Disk (LU) in Pool |
1GB |
4TB |
|
Number of
Repository Disks |
1 |
1 |
|
Capacity
of Repository Disk |
10GB |
1016GB |
|
Number of
Client LPARs per Cluster |
1 |
2000 |
Prerequisites for expanded support:
Here are the new maximum values for each of these
configuration options, if the associated hardware specification has been met:
|
Feature |
Default
Max |
High
Spec Max |
|
Number of
VIOS Nodes in Cluster |
16 |
24 |
|
Number of
Client LPARs per VIOS node |
250 |
400 |
Network Configuration
Storage Configuration
Shared Storage Pool capabilities and limitations
Please ensure that your rootvg contains at least 30 GB and that there is at
least 4GB free space before you attempt to update to
Update Release 4.1.2.10. Run the lsvg rootvg command, and
then ensure there is enough free space.
Example:
$ lsvg rootvg |
|
|
|
VOLUME GROUP: |
rootvg |
VG IDENTIFIER: |
00f6004600004c000000014306a3db3d |
VG STATE: |
active |
PP SIZE: |
64 megabyte(s) |
VG PERMISSION: |
read/write |
TOTAL PPs: |
511 (32704 megabytes) |
MAX LVs: |
256 |
FREE PPs: |
64 (4096 megabytes) |
LVs: |
14 |
USED PPs: |
447 (28608 megabytes) |
OPEN LVs: |
12 |
QUORUM: |
2 (Enabled) |
TOTAL PVs: |
1 |
VG DESCRIPTORS: |
2 |
STALE PVs: |
0 |
STALE PPs: |
0 |
ACTIVE PVs: |
1 |
AUTO ON: |
yes |
MAX PPs per VG: |
32512 |
|
|
MAX PPs per PV: |
1016 |
MAX PVs: |
32 |
LTG size (Dynamic): |
256 kilobyte(s) |
AUTO SYNC: |
no |
HOT SPARE: |
no |
BB POLICY: |
relocatable |
PV RESTRICTION: |
none |
INFINITE RETRY: |
no |
When the user upgrades from 3.1.x.y to 4.1.0.00
level and above, third-party software is not packaged with the IBM supplied mksysb image. User needs to install the respective
third-party software after the upgrade is complete and run viosupgrade
-o rerun to restore the respective devices.
VIOS Update
Release 4.1.2.10 may be applied directly to any VIOS at level 4.1.0.00.
Warning: The
update may fail if there is a loaded media repository.
To check for a
loaded media repository, and then unload it, follow these steps.
1. To check for loaded images, run the following command:
$ lsvopt
The Media column lists any loaded media.
2. To unload media images, run the following commands on all Virtual Target
Devices that have loaded images.
$ unloadopt -vtd <file-backed_virtual_optical_device >
3. To verify that all media are unloaded, run the following command again.
$ lsvopt
The command output should show No
Media for all VTDs.
The Virtual I/O
Server (VIOS) Version 3.1.x.y or later, supports rolling updates to release
4.1.2.10 for SSP clusters.
The rolling
updates enhancement allows the user to apply Update Release 4.1.2.10 to the
VIOS logical partitions in the cluster individually without causing an outage in
the entire cluster. The updated VIOS logical partitions cannot use the new SSP
capabilities until all VIOS logical partitions in the cluster are updated.
To upgrade the
VIOS logical partitions to use the new SSP capabilities, ensure that the
following conditions are met:
· All VIOS logical partitions must have VIOS
Update Release version 3.1.x.y or later installed.
·
All VIOS logical partitions must be
running. If any VIOS logical partition in the cluster is not running, the cluster
cannot be upgraded to use the new SSP capabilities.
Instructions: Verify
the cluster is running at the same level as your node.
1. Run the following command:
$ cluster -status -verbose
2. Check the Node Upgrade Status field, and you should see one of the
following terms:
UP_LEVEL: This means that the software level of the logical partition is higher
than the software level the cluster is running at.
ON_LEVEL: This means the software level of the logical partition and the
cluster are the same.
There is a method
to verify the VIOS update files before installation. This process requires
access to openssl by the 'padmin'
User, which can be accomplished by creating a link.
Instructions: Verifying VIOS update files.
To verify the VIOS
update files, follow these steps:
1. $ oem_setup_env
2. Create a link to openssl if required
# ln
-s /usr/bin/openssl /usr/ios/utils/openssl
3.
Verify the link to openssl
was created
# ls
-alL /usr/bin/openssl /usr/ios/utils/openssl
4.
Verify that both files display similar
owner and size
5. # exit
Use one of the
following methods to install the latest VIOS Service Release. As with all
maintenance, you should create a VIOS backup before making changes.
If you are running
a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.
Note:
While running 'updateios' in the following steps, you
may see accessauth messages, but these messages can safely be
ignored.
Warning: If VIOS rules
have been deployed.
During update, there have been occasional issues with VIOS Rules files getting
overwritten and/or system settings getting reset to their default values.
To ensure that this doesn’t affect you, we
recommend making a backup of the current rules file. This file is located here:
/home/padmin/rules/vios_current_rules.xml
First, to capture your current system settings, run this command:
$ rules
-o capture
Then, either copy the file to a backup
location, or save off a list of your current rules:
Note:
The "padmin" user is restricted to redirect
command output to a file, you must be in the root shell. Use "oem_setup_env" to become a root user.
$ oem_setup_env
#
rules -o list > rules_list.txt
After this is complete, proceed to update
as normal. When your update is complete,
check your current rules and ensure that they still match what is desired. If not, either overwrite the original rules file
with your backup, or proceed to use the ‘rules -o modify’ and/or ‘rules -o add’
commands to change the rules to match what is in your backup file.
Finally, if you’ve failed to back up your
rules, and are not sure what the rules should be, you can deploy the
recommended VIOS rules by using the following command:
$ rules -o deploy -d
Then, if you wish to copy these new VIOS
recommended rules to your current rules file, just run:
$ rules -o capture
Note: This will overwrite
any customized rules in the current rules file.
Applying Updates
Warning:
If the target node
to be updated is part of a redundant VIOS pair, the VIOS partner node must be
fully operational before beginning to update the target node.
Note 1:
For VIOS nodes
that are part of an SSP cluster, the partner node must be shown in 'cluster
-status ' output as having a
cluster status of OK and a pool status of OK. If the target node is updated before
its VIOS partner is fully operational, client LPARs may crash.
Note 2:
Updateios command is suggested to run using
“-install” option. This option installs new base-level filesets
that are shipped along with the existing fileset
updates. For example: enabling resize command in VIOS 4.1.2.10 onwards.
Running updateios
command with “-install” flag may lead to few fileset
update error messages that can be ignored. See below the list of filesets for which the error message can be ignored:
X11.apps.msmit 7.3.3.0 # AIXwindows
msmit Application
bos.msg.ca_ES.mls.rte 7.3.3.0 # Trusted AIX Messages - Catalan
bos.msg.ca_ES.svprint 7.3.3.0 # System V Print Subsystem Msg...
bos.msg.de_DE.mls.rte 7.3.3.0 # Trusted AIX Messages - German
bos.msg.de_DE.svprint 7.3.3.0 # System V Print Subsystem Msg...
bos.msg.en_US.mls.rte 7.3.3.0 # Trusted AIX Messages - U.S. ...
bos.msg.es_ES.mls.rte 7.3.3.0 # Trusted AIX Messages - Spanish
bos.msg.es_ES.svprint 7.3.3.0 # System V Print Subsystem Msg...
bos.msg.fr_FR.mls.rte 7.3.3.0 # Trusted AIX Messages - French
bos.msg.fr_FR.svprint 7.3.3.0 # System V Print Subsystem Msg...
bos.msg.it_IT.mls.rte 7.3.3.0 # Trusted AIX Messages - Italian
bos.msg.it_IT.svprint 7.3.3.0 # System V Print Subsystem Msg...
bos.msg.pt_BR.mls.rte 7.3.3.0 # Trusted AIX Messages - Brazi...
bos.msg.pt_BR.svprint 7.3.3.0 # System V Print Subsystem Msg...
bos.net.tcp.rcmd 7.3.3.0 # TCP/IP Remote Command
Client...
bos.net.tcp.rcmd_server 7.3.3.0 # TCP/IP Remote Command Server...
Also,
In case you choose to run updateios
without “-install” flag, you will not see any of the error messages above but
you will lose installation of resize command and “RSCT Software Resource
Manager” along with a bunch of language message filesets
for locales “it_IT, fr_FR, ca_ES, pt_BR, de_DE,
es_ES”. Below is the list of filesets
that you will miss:
bos.msg.it_IT.txt.tfs - Text Formatting Services Msgs
- Italian
bos.msg.it_IT.net.ipsec - IP Security Messages - Italian
bos.msg.it_IT.alt_disk_inst - Alternate Disk Install Msgs
-Italian
bos.msg.it_IT.diag.rte - Hardware Diagnostics Messages - Italian
(Same filesets as above for fr_FR, ca_ES, pt_BR,
de_DE, es_ES)
X11.apps.xterm - AIXwindows xterm Application
X11.apps.xdm - AIXwindows xdm
Application
X11.apps.custom - AIXwindows Runtime Common
Directories
X11.apps.config - AIXwindows Configuration
Applications
X11.apps.clients - AIXwindows Client
Applications
rsct.msg.EN_US.basic.rte - RSCT Basic Msgs - U.S.
English (UTF)
rsct.opt.softwarerm - RSCT Software Resource Manager
rsct.msg.en_US.opt.software - RSCT Software RM Msgs -
U.S. English
rsct.msg.EN_US.opt.software - RSCT Software RM Msgs -
U.S. English (UTF)
Warning:
Update to VIOS 4.1.2.10 will update ios.database.rte fileset which
might throw below errors, and they can be ignored:
Instructions: Applying updates to a VIOS.
2. Using ftp, transfer the update file(s) to the directory you created.
To apply updates from a remotely mounted file system, and the remote file
system is to be mounted read-only, follow the steps:
The update release
can be burned onto a CD by using the ISO image file(s). To apply updates from
the CD/DVD drive, follow the steps:
$ shutdown
-restart
Note: If shutdown –restart command failed, run swrole –PAdmin for padmin to set authorization and establish access to the shutdown command properly.
$ clstartstop -start -n <cluster_name > -m <hostname >
$ ioslevel
Instructions: Checking for an incomplete installation caused by a loaded media
repository.
After installing
an Update Release, you can use this method to determine if you have encountered
the problem of a loaded media library.
Check the Media
Repository by running this command:
$ lsrep
If the command
reports: "Unable to retrieve repository data due to incomplete repository
structure," then you have likely encountered this problem during the
installation. The media images have not been lost and are still present in the file
system of the virtual media library.
Running the lsvopt command should show the media images.
Instructions: Recovering from an incomplete installation
caused by a loaded media repository.
To recover from
this type of installation failure, unload any media repository images, and then
reinstall the ios.cli.rte package. Follow these steps:
1. Unload any media images
$ unloadopt -vtd <file-backed_virtual_optical_device>
2. Reinstall the ios.cli.rte fileset by running the following commands.
To escape the restricted
shell:
$ oem_setup_env
To install the failed fileset:
# installp –Or –agX ios.cli.rte –d <device/directory >
To return to the restricted
shell:
# exit
3. Restart the VIOS.
$ shutdown
–restart
4. Verify that the Media Repository is operational by running this command:
$ lsrep
Software Updated
· The filesets that contain the PostgreSQL13 and
PostgreSQL15 versions are available in VIOS.
o The PostgreSQL15 version is updated to the PostgreSQL15.12 version
o The PostgreSQL13 version is updated to the PostgreSQL13.20 version
· You must add the -install option while you run the updateios
command to install the following PostgreSQL filesets:
o ios.viodb13.rte
o ios.viodb15.rte
· If you don’t have SSP or SSP doesn’t have 4.1.0.00 prior versions nodes,
then you may remove ios.viodb13.rte fileset.
o Once the ios.viodb13 is removed, the node can never be added back to SSP
with prior version nodes.
· The Bind.rte fileset
is added to the VIOS expansion pack
ITM Agents software
ITM (IBM Tivoli
Monitoring) filesets are not part of VIOS 4.1.0.00
& above versions. Users need to download and install the ITM software from
an external location. The ITM VIOS Premium Agent and ITM CEC Base Agent can be
downloaded and installed separately as part of an updated IBM Tivoli Monitoring
System P Agents 6.22 Fix Pack 4 or later bundle. Here is a link to the readme file containing information about how to obtain the image
and instructions for installing. When
these agents are installed in the default directory of /opt/IBM/ITM, they can
continue to utilize the cfgsvc, startsvc,
and stopsvc commands to configure, start and stop the
agent.
AMS
Active Memory Sharing
(AMS) feature is removed.
Software Removed
Following filesets
that are deemed not necessary are removed.
· bos.net.tcp.rcmd, bos.net.tcp.rcmd_server (A copy is saved
under: /usr/sys/inst.images/installp/ppc)
· cas.agent tivoli.tivguid
· rsct.opt.fence.blade rsct.opt.fence.hmc
· sysmgt.cim.providers.metrics sysmgt.cim.providers.osbase
· sysmgt.cim.providers.scc sysmgt.cim.providers.smash
· sysmgt.cim.smisproviders.hba_hdr sysmgt.cim.smisproviders.hhr
· sysmgt.cim.smisproviders.vblksrv sysmgt.cimserver.pegasus.rte
· Java7.jre Java7.sdk Java7_64.jre Java7_64.sdk
· itm.cec.agent itm.premium.rte itm.vios_premium.agent
· bos.net.nfs.server devices.vdevice.IBM.vfc-client.rte
· X11.adt.ext X11.adt.motif X11.apps.clients X11.apps.config
X11.apps.custom X11.apps.msmit X11.apps.xdm
· X11.apps.xterm X11.base.xpconfig X11.compat.adt.Motif12
X11.compat.lib.Motif10 X11.compat.lib.Motif114
· X11.compat.lib.X11R3 X11.compat.lib.X11R4 X11.Dt.bitmaps X11.Dt.helpinfo
X11.Dt.helpmin X11.Dt.helprun
· X11.Dt.lib X11.Dt.rte X11.Dt.ToolTalk X11.fnt.coreX X11.fnt.deform_JP X11.fnt.fontServer
X11.fnt.Gr_Cyr_T1
· X11.fnt.ibm1046 X11.fnt.ibm1046_T1 X11.fnt.iso1 X11.fnt.iso2
X11.fnt.iso3 X11.fnt.iso4 X11.fnt.iso5
· X11.fnt.iso7 X11.fnt.iso8 X11.fnt.iso8_T1 X11.fnt.iso9 X11.fnt.iso_T1
X11.fnt.ksc5601.ttf X11.fnt.ucs.cjk
· X11.fnt.ucs.com X11.fnt.ucs.ttf_CN X11.fnt.ucs.ttf_extb X11.fnt.util
X11.loc.en_US.base.lib
· X11.loc.en_US.base.rte X11.loc.en_US.Dt.rte X11.vsm.lib
Removal of Legacy Font Families
Starting with Virtual I/O Server (VIOS) 4.1.2.10, IBM has discontinued
support for the following legacy font families and removed all their variants:
· Courier (including Symbol variants)
· Helvetica (including Symbol variants)
· Times New Roman (including Symbol variants)
· WorldType (including
Chinese variants)
These fonts were previously standard components in the VIOS Font
Collection, but will no longer be included with the VIOS.
The impact of font removal depends on the installation method (VIOS updates vs.
fresh installation):
· Updating existing VIOS to VIOS 4.1.2.10: existing legacy fonts will be
preserved during the update process.
· Fresh installations: for fresh installation of VIOS 4.1.2.10 (or later),
legacy fonts will not be available.
|
APAR |
Description |
|
IJ56381 |
RACE CONDITION BETWEEN CLOSING OF TCP SERVER AND CLIENT SOCKETS |
|
IJ56809 |
CONFIG ROUTINES OR INCREASE IN MEMTRACEBUFSIZE CAN FAIL ENOMEM |
|
IJ56822 |
SYSTEM HANG DUE TO INCORRECT TIMESTAMP IN TCPCB |
|
IJ56924 |
NIMADM FAILS WITH SYNTAX ERROR WHEN USING A MIXED LPP_SOURCE |
|
IJ56952 |
i/o
might hung during link down with fast_lnk_recov
enabled |
|
IJ56954 |
COMMON_ERR_0080 ERRLOG ENTRY DURING IBMI SHUTDOWN |
|
IJ56959 |
XSTORM COUNTER OF EN0W ADAPTER IS NOT INCREMENTED BY FIRMWARE |
|
IJ56961 |
DEADLOCK IN WATCHDOG MANAGEMENT IN VLANDD |
|
IJ56963 |
COMMANDS MIGHT HAND AT ISCSI RELOGIN FAILURE |
|
IJ56965 |
Probable I/O hang with fcstat during
driver init |
|
IJ56966 |
lstcpnvme
returns Empty Output for passw |
|
IJ56967 |
Dynamic QoS allocation didnot happen
after rmdev of all vfchosts |
|
IJ56968 |
AIX may hang after FC HBA firmware update |
|
IJ56969 |
LPM LUN LEVEL VALIDATION - MASKING ISSUE WITH TAPE |
|
IJ56970 |
RoCE Adapters FC EC2N/EC3A registration with OFED may fail |
|
IJ56971 |
Missing size attribute in xml response for nfs
media files |
|
IJ56973 |
AHAFS SYSTEM CRASH AT AHAFSSTKTRACE |
|
IJ56975 |
local mailbox fail to check MASQUERADING with current submit.cf |
|
IJ56978 |
DROP IN LDAP NETGROUP PERFORMANCE |
|
IJ56980 |
getifaddrs()
fails to list aliases set on interfaces |
|
IJ56982 |
LPARSTAT -E SHOWS WRONG PROCESSOR FREQUENCY |
|
IJ56985 |
NIM INSTALL SHOWS AN ERROR MESSAGE ON THE CONSOLE. |
|
IJ56986 |
SMBC FILESYSTEMS ARE NOT UNMOUNTED BY AUTOMOUNTD |
|
IJ56987 |
BRING UP A VIPA INTERFACE WITH 32BIT NETMASK FAILS |
|
IJ56988 |
libSpmi libary compilation fails with FILEDB flag set |
|
IJ56990 |
Topas update for removing the LPM message once LPM is completed |
|
IJ56991 |
virtualcfg
command got coredumped (viosbr
restore) |
|
IJ57001 |
Bug in sys/iocp.h causing compiler
error |
|
IJ57002 |
viosbr
restore might fail to restore security configuration |
|
IJ57006 |
NULL not defined consistently for C on AIX with Clang |
|
IJ57009 |
Buffer overflow with strncat() on
power10 mode |
|
IJ57010 |
ERRPT FOR J2_FORCE_UNMOUNT MAY GIVE AN INCORRECT LV/FS NAME |
|
IJ57011 |
CRASH DUE TO MEM CORRUPTION WHEN USING SYSLOG-NG |
|
IJ57012 |
PIGZ CAN CRASH PARTITION WHEN USING GZIP HW ACCELERATOR (P9/P10) |
|
IJ57013 |
LPAR may crash while handling interrupt |
|
IJ57016 |
FSCK RUNS EVEN THOUGH FILESYSTEM ISN'T FULLY UNMOUNTED |
|
IJ57019 |
Core dump of user-space application that uses RSET after an LKU. |
|
IJ57020 |
Boot of AIX fails as kernel memory allocation failed |
|
IJ57120 |
system crash in process table or detach exit |
|
IJ57141 |
LEFTOVER LVUP_NETWORK IN LVUP_SCRIPT |
|
IJ57142 |
IN VIOS 4.1 SNAP MAY NOT COLLECT SSPDB AND HSDB |
|
IJ57151 |
alt_disk_mksysb is
not retaining extra mount option |
|
IJ57154 |
Firmware Update with IO on NVMe
devices may cause HW Error |
|
IJ57157 |
System firmware update fails with update_flash
command |
|
IJ57159 |
UNABLE TO LOCATE VALID VGDA ON PHYSICAL VOLUMES |
|
IJ57163 |
NIMADM MAY FAIL WITH INSTALLP_BUNDLE |
|
IJ57164 |
RESTWPAR TO NON-ROOTVG FAILED WITH MKFS ERROR MESSAGE |
|
IJ57167 |
wrong symbol for VSX related millicode
routines in KDB |
|
IJ57168 |
Update splpar structure as per
specification |
|
IJ57169 |
WTMP FILE IS CLEARED ON VIO SERVERS |
|
IJ57197 |
POOLFS COMMAND UPDATESTALECOUNT MAY FAIL |
|
IJ57232 |
Vulnerabilities in X-server and Xorg |
|
IJ57234 |
kernel heap memory leak in vmap alloc |
|
IJ57253 |
BACKBYINODE CORE DUMPS |
|
IJ57254 |
MIGRATELP MAY RESULT IN INCORRECT LOGICAL VOLUME MAPPING |
|
IJ57255 |
DRM needs to add LogService capability |
|
IJ57271 |
UNMIRRORVG REMOVES INCORRECT MIRROR COPY IF PVID MISSING IN ODM |
|
IJ57279 |
alt_disk_copy fail
for encrypted LV with PKS AUTH |
|
IJ57281 |
HOME DIRECTORY CREATION MIGHT RESULT IN BAD PERMISSIONS |
|
IJ57282 |
A potential security issue exists |
|
IJ57288 |
EMGR_CHECK_IFIXES SHOWS ERRORS WITH LANG OTHER THAN C OR EN_US |
|
IJ57374 |
nimadm fails
in phase 1 to create lv hd5 |
|
IJ57375 |
Adding errpt entry when logredo is skipped |
|
IJ57376 |
VIOSUPGRADE COMPLETED REPORT SECURITY CONFIGURATION ERROR |
|
IJ57378 |
SFP DATA MONITORING MAY LEAD TO FCA_ERR4 ERROR |
|
IJ57381 |
ioslevel
change to 4.1.2.10 |
|
IJ57384 |
IPV6 DOESN'T WORK OUTSIDE OF THE LOCAL SUBNET |
|
IJ57431 |
err observed in trustchk_log |
|
IJ57432 |
hdcryptmgr
dumped core with pvenable for multiple disks |
|
IJ57434 |
vios_sec_backrest
create tar ball with relative path |
|
IJ57442 |
UNKNOWN USER IN /ETC/MOBTE/MODELS DIRECTORY |
|
IJ57443 |
ISVD migration failure from 10.0.3.1 to 10.0.4.2 schema issues |
|
IJ57448 |
Change the rfc7217 key length to 256 bit |
|
IJ57449 |
Error msg shows HPCS in keysvrmgr add and modify |
|
IJ57461 |
JFS2 ROOT FS ("/") ATTRIBUTE CHANGES DON'T PERSIST
AFTER REBOOT |
|
IJ57474 |
SR-IOV firmware update initial IP assignment fails |
|
IJ57476 |
VIOSBR BREAKS WHEN A IP DOES NOT HAVE NAME RESOLUTION |
|
IJ57479 |
Exclude cede/confer hcall statistics
from the %hypv computation |
|
IJ57481 |
AIX lpar crashed
@nx_allocate_window+0002E4 |
|
IJ57483 |
ISCSI HDISK LOST LUN RESET LEADS TO I/O HANG |
|
IJ57484 |
Non Secure Firmware upgrade flow modified. |
|
IJ57485 |
potential system crash due to wrong index used in tce_mirror |
|
IJ57486 |
Additional RAS for lvm commands |
|
IJ57532 |
Update kernel copyright notice for 2026 |
|
IJ57594 |
VEA SMQ interrupt may cause CPU starvation, degrading vSCSI I/O. |
|
IJ57657 |
Core dumped for the tcpnvme kdb sub-command. |
|
IJ57659 |
Latency is not set for Power11 processor during thresholding |
|
IJ57660 |
error while doing umnt mnt in a loop |
|
IJ57661 |
IO MIGHT HANG ON LOGICAL VOLUMES WITH SERIALIZED IO ENABLED |
|
IJ57744 |
Create of Etherchannel allow when port
is unavai |
|
IJ57746 |
Upgrade Failure: Older Firmware with MFAI-Only Support Cannot T |
|
IJ57747 |
Updated transceiver diagnostics for dedicated and shared mode |
|
IJ57754 |
mc_func
replacements for header atomic_op.h, buf.h, machine.h |
|
IJ57755 |
Modify traces for fragmented neighbour discovery packets |
|
IJ57764 |
Command fails after 15 seconds despite LUROnErr_retry=5 |
|
IJ57767 |
EMGR_CHECK_IFIXES FAILS WHEN PROXY USERID HAS SPECIAL CHARACTER |
|
IJ57799 |
ERRORS WHILE EXECUTING SVMON -SL COMMAND |
|
IJ57836 |
smtctl fails
incase of invalid TZ |
|
IJ57837 |
REPEATED ISCSI CONNECT ATTEMPTS LEAK MBUF |
|
IJ57839 |
auditpr -W cmd does not ignore newline char in audit log |
|
IJ57840 |
Stack optimization in tcp usrreq |
|
IJ57841 |
IPREPORT PRINTS LARGE 64BIT NUMBER AS NEGATIVE |
|
IJ57842 |
Crypto key initialization fails |
|
IJ57845 |
AIX lex generates non-standard c code, causing compile failures |
|
IJ57846 |
secrete key file should not be restored after mksysb |
|
IJ57848 |
Applications with private loaded libs dump core if LLU enabled |
|
IJ57873 |
SYSTEM HANG IN KSUSPEND |
|
IJ57874 |
VKE_ERR : FAILED TO REGISTER THE OS MONITOR |
|
IJ57875 |
LKU FAILURE DUE TO IMPROPER MILLICODE REFERENCE COUNT |
|
IJ57882 |
Timezone
update 2026a |
|
IJ57883 |
Fix transport recovery post EEH for VFC_host |
|
IJ57932 |
KSH93: INDEX=1594013 MARKER=814 ERRORS WHEN BREAKING SESSION |
|
IJ58022 |
ATTRIBUTE TO ENABLE/DISABLE MLXCENT_TRANSCEIVER ERROR IN ERRPT |
|
IJ58028 |
Need information on
required size wrt mksysb
install |
|
IJ58063 |
RUNNING CHNFSMNT COMMAND CHANGES PARAMETER MAXGROUPS TO RETRANS |
|
IJ58064 |
RLOGIND HOLDS /ETC/PASSWD OPEN |
|
IJ58069 |
SIGN policy not set on NIM_cli post migr using nimadm |
|
IJ58096 |
SEA SHARING MODE NOT WORKING AFTER UPDATE TO 4.1.2.0 |
|
IJ58119 |
vNIC
Adapter reset count gets incremented for a disable ioctl |
|
IJ58122 |
A potential security issue exists |
|
IJ58143 |
EMGR_CHECK_IFIXES FAILS TO GET FIXES ON 7300-04-00-2546 |
|
IJ58151 |
Cleanup issue if we ship new binary file through efix |
|
IJ58154 |
VIOS_VFC_HOST(ERRNUM 0000 0102) MISS TARGET PORT WHO LEFT SAN |
|
IJ58158 |
Lpar
crashed due to accessing null pointer |
|
IJ58160 |
NIMADM FAILED FOR CLIENTS WITH MIXED JFS AND JFS2 ON ROOTVG |
|
IJ58164 |
EMGR_CHECK_IFIXES -D AIX_LEVEL:FIRMWARE_LEVEL FAILS WITH PROXY |
|
IJ58183 |
CUSTOM USERS NOT ABLE TO LOGIN POST VIOSUPGRADE TO 4.1.2.0 |
|
IJ58185 |
IPSEC FILTER NOT STARTING DUE TO ODM CODE CHANGE IN AIX 7.3 TL04 |
|
IJ58186 |
VIOSBR WITH FREQUENCY DOES NOT CONTAIN /DEV/NULL |
|
IJ58196 |
5% performance degradation |
|
IJ58212 |
BACKUPIOS MAY FAIL FOR CERTAIN TAPES |
|
IJ58214 |
migr
restarts at 42% |
|
IJ58215 |
ESA Code Fixes for 7.3.4.1 |
|
IJ58216 |
cfgpkcs11 crash with LKU |
|
IJ58217 |
system crash at xtValidatePage+0001A0 |
|
IJ58230 |
i/o may
experience prolonged delays under PCM quiesce conditio |
|
IJ58231 |
VIOS crashes in i_clear |
|
IJ58247 |
BACKUPIOS FAILS WITH USAGE ERROR WHEN USER VG EXIST AT 4.1.1 |
|
IJ58251 |
LOCAL USER'S LDAP GROUPS DISAPPEAR |
|
IJ58252 |
LPM validation fails with FC-NVMe NPIV
disks. |
|
IJ58276 |
UNEXPECTED ODMDIR VALUE CAUSES 0518-507 IN PHASE 5 OF NIMADM |
|
IJ58280 |
system crashed at tbl get path |
|
IJ58281 |
Implement New MCIA Register Instead of MAD_IFC for Transceiver |
|
IJ58282 |
trustchk
db on LDAP and efs
keystore LDAP won't work. |
|
IJ58297 |
LD WITH -BSTABSPLIT AND DWARF MAY COREDUMP WITH BIG OUTPUTS |
|
IJ58298 |
TRUSTCHK -K CREATES CERTIFICATES VALID FROM MAY 2006 TO 2016 |
|
IJ58299 |
AWK USING STRING FUNCTIONS ON RECORD THEN ON FIELD LEAK |
|
IJ58301 |
SHAENTDD LOGS SHAENT_SW_ER WHEN IT TRANSMITS SMALL MSS PACKET |
|
IJ58302 |
IN NPIV ENV DEFERRED LOGIN COULD CAUSE IO HANG |
|
IJ58303 |
failure to define custom malloc via macros |
|
IJ58304 |
DIRECTORY MAY BE REMOVED IF IT SHARES THE SAME PATH AS LPP |
|
IJ58305 |
udapl
samples in /usr/samples/udapl/rdma_write do not work |
|
IJ58316 |
REPEATED FAILED SOCKET CREATIONS MAY CAUSE CRASH |
|
IJ58317 |
iFix
install on SPOT failed |
|
IJ58396 |
trustchk -g is
not setting the hash_algorithm |
|
IJ58401 |
PART SHOWS WRONG BANDWIDTH UTILIZATION OF NPIV CLIENTS. |
|
IJ58402 |
NMON SHOWS INCORRECT FCSUPPSPEED FOR 16,32,64,100 GB ADAPTERS |
|
IJ58405 |
Rename rx limit to sw
rx limit |
|
IJ58406 |
Printing the transceiver dynamic range values in entstat output |
|
IJ58409 |
migration install not failing when UAK expired |
|
IJ58411 |
2nd LKU might fail while running with ldap+db2. |
|
IJ58412 |
LKU+LLU might fail for few specific cases |
|
IJ58420 |
PCI device config may hang if slot in EEH error state |
|
IJ58457 |
Incorrect MCIA Register Query for Transceiver Statistics. |
|
IJ58458 |
Hsmon
inoperative after viosupgrade from 3.1.4 to 4.1.2 |
|
IJ58459 |
Crypto key initialization fails |
|
IJ58472 |
keeping the old fall back method for UAK_Check |
|
IJ58481 |
0590-102 INCORRECT PROFILE DURING UPDATEIOS 4.1.1 TO 4.1.2.00 |
|
IJ58484 |
binary fails to load when shrsymtab
linker option is used |
|
IJ58533 |
A potential security issue exists |
|
IJ58556 |
ILMT
with nimadm |
|
IJ58580 |
Need information on
required size wrt mksysb
install |
|
IJ58608 |
Error log shows INFO type error DMA_ERR (PCIDMA) |
|
IJ58618 |
LKU failed with ldap+db2 config |
|
IJ58619 |
bos.net.ipsec.rte
7.3.5.0: installation |
|
IJ58670 |
ASO memory leak and core dump if workload creates and destroys |
|
IJ58671 |
LPM is using 10G network for data transfer when there are 10G ( |
|
IJ58676 |
Probable IO failure during adapter error recovery case. |
|
IJ58721 |
ASO core dump with LPM |
|
IJ58733 |
Remote restart fails when starting a port returns EBUSY |
|
IJ58799 |
mismatch betwn mcr_rbacsetup.sh and mcr.rte.sec.S file |
|
IJ58807 |
Trust check verification during update of AIX fail on fileset |
|
IJ58819 |
A potential security issue exists |
|
IJ58876 |
c_rsh is
not happening post nim viosupgrade |
|
IJ58892 |
NIM FORCE SYNC DISPLAYS 0042-008 REQUEST DENIED AT THE END |
|
IJ58893 |
NIM reversion companion defect |