PACKAGE: Update Release 3.1.4.41
IOSLEVEL: 3.1.4.41
|
VIOS level is |
The AIX level of the NIM Master
level must be equal to or higher than |
|
Update Release 3.1.4.41 |
AIX
7200-05-08 |
Be sure to heed all minimum space requirements before
installing.
Review the list of fixes included in Update Release 3.1.4.41
To take full advantage of all the functions available
in the VIOS, it may be necessary to be at the latest system firmware level. If
a system firmware update is necessary, it is recommended that the firmware be
updated before you update the VIOS to Update Release 3.1.4.41.
Microcode or system firmware
downloads for Power Systems
If the VIOS being updated has filesets installed from
the VIOS Expansion Pack, be sure to update those filesets with the latest VIOS
Expansion Pack if updates are available.
Update Release 3.1.4.41
updates your VIOS partition to ioslevel 3.1.4.41.
To determine if Update Release 3.1.4.41
is already installed, run the following command from the VIOS command line.
$ ioslevel
If Update Release 3.1.4.41
is installed, the command output is 3.1.4.41.
Note: The VIOS installation DVDs and the level of VIOS
preinstalled on new systems might not contain the latest fixes available. It’s
highly recommended that customers that get the physical GA level (i.e.,
3.1.4.30) to update to the electronic GA levels (i.e., 3.1.4.41) as soon as
possible. Missing fixes might be critical to the proper operation of your
system. Update these systems to a current service pack level from Fix Central.
For Customers using NVMe Over
Fabric (SAN) as their Boot Disk
Booting from NVMeoF disk may fail if
certain fabric errors are returned, hence a boot disk set up with multiple
paths is recommended. In case there is a failure to boot, the boot
process may continue if you exit from the SMS menu. Another potential
workaround is to discover boot LUNs from the SMS menu and then retry boot.
For Customers Using Third Party
Java-based Software
This only applies to customers who both use third
party Java based software and have run updateios -remove_outdated_filesets to
remove Java 7 from their system.
To prevent errant behavior when editing customer’s /etc/environment file,
updateios does not make changes to that file when run. If a customer is using
software that depends on using Java and having the path to it in your PATH
environment variable, the following edit should be made to allow programs that
use the PATH environment variable to locate Java 8.
In
the /etc/environment file, customers should see:
PATH=[various
directories]:/usr/java7_64/jre/bin:/usr/java7_64/bin
To
address a potential issue with Java-dependent third party software, this should
be converted to:
PATH=[various
directories]:/usr/java8_64/jre/bin:/usr/java8_64/bin
ITM
Agents Software
ITM (IBM Tivoli Monitoring) filesets continue to be pre-installed
as part of VIOS 3.x. The agents can be updated using one of the methods
below:
·
To update the agent and shared
components (e.g. JRE, GSKt) to the latest levels, download the latest image
included in the IBM Tivoli Monitoring System P Agents 6.22 Fix Pack 4 bundle
. Here is a link
to the readme file containing information about how to obtain the image and
instructions for installing.
·
To update just the agent shared
components (e.g JRE, GSKit), the latest ITM service pack can be installed.
LDAP
fileset updates
For VIOS partitions originally installed at 3.1.4.30 or later,
errors updating the idsldap 6.4 filesets can be safely ignored as version 10.0
of the idsldap filesets are already present on the system.
Please
ignore below errors:
installp: APPLYING
software for:
idsldap.license64.rte 6.4.0.25
…
…
Error: IBM Security Directory Server License not
detected. Install cannot continue.
instal: Failed
while executing the idsldap.license64.rte.pre_i script.
0503-464 installp:
The installation has FAILED for the "usr" part
of the
following filesets:
idsldap.license64.rte 6.4.0.25
installp:
Cleaning up software for:
idsldap.license64.rte 6.4.0.25
Please
ignore below entries in “Installation Summary” :
idsldap.license64.rte 6.4.0.25 USR APPLY FAILED
idsldap.license64.rte 6.4.0.25 USR CLEANUP SUCCESS
idsldap.cltbase64.rte 6.4.0.25 USR APPLY CANCELED
idsldap.cltbase64.adt 6.4.0.25 USR APPLY CANCELED
idsldap.clt64bit64.rte 6.4.0.25 USR APPLY CANCELED
idsldap.clt32bit64.rte 6.4.0.25 USR APPLY CANCELED
Note
·
If the Virtual I/O servers are installed on POWER10 systems and configured
with “32Gb PCIe4 2-Port FC Adapter, Feature Code(s) EN1J and EN1K”, then the
requirement is to update the adapter microcode level to 7710812214105106.070115 before updating the Virtual
I/O server to 3.1.4.41 level.
Please refer to the release notes at this link
VIOS 3.1.4.41 adds the
following new features:
VIOS Shared
Storage Pool Logging Enhancements
The two major enhancements for VIOS Shared Storage
Pool in this release are as follows:
· The
creation of dbn.log file
within a
Shared Storage Pool (SSP).
This file tracks all elections and
relinquishes of the Database Node (DBN) role and debugs DBN-related
problems easily.
· The
compression and storage of vio_daemon logs.
The number of logs that
can be retained is increased by 15 times with no impact to storage capacity.
This is done by compressing old VIOS logs and by tagging them with appropriate
date and time information. This reduces the risk of logs that might contain
critical information from being overwritten by newer logs.
N_Port ID Virtualization (NPIV) Enhancements: NVMeoF
Protocol Support
The NPIV is a
standardized method for virtualizing a physical Fibre Channel (FC) port. An
NPIV-capable FC host bus adapter (HBA) can have multiple N_Ports, each
with a unique identity. The NPIV, coupled with the adapter-sharing capabilities
of the Virtual I/O Server (VIOS), allows a physical Fibre Channel HBA to be
shared across multiple guest operating systems. The PowerVM implementation of
NPIV enables POWER® logical partitions (LPARs)
to have virtual fibre channel host bus adapters,
each with a dedicated
worldwide port name.
Each virtual Fibre Channel HBA has a unique storage area network (SAN) identity
similar to that of a dedicated physical HBA.
The Non-Volatile Memory Express over Fabrics (NVMeoF) protocol in the NPIV
stack is supported in Virtual I/O Server Version 3.1.4.0. A single virtual
adapter provides access to both Small Computer Systems Interface (SCSI) and
NVMeoF protocols if the physical adapter can support them. The application,
which is running on the client partition and capable of handling the
NPIV-NVMeoF protocol, can send I/Os in parallel to SCSI and NVMeoF disks that
are coming from a single virtual adapter. The hardware and software
requirements for NVMeoF protocol enablement in the NPIV stack are as follows:
· VIOS
Version 3.1.4.0, or later
· NPIV-NVMeoF
capable client (currently AIX®
Version 7.3
Technology Level 01, or later)
· POWER
10 system with firmware version FW 1030, or later
· 32
or 64 GB FC adapters with physical NVMeoF support
VIOS
Operating System Monitoring Enhancement
This release adds support for monitoring the VIOS
operating system state by the POWER Hypervisor. If the VIOS
partition is not responsive (due to certain conditions), then the hypervisor
restarts the VIOS partition while it takes the system dump for debugging
purpose. This helps to recover the VIOS partition from errors, for example, if
the CPU is hijacked by the highest-level interrupt, the system progress is
stopped. The ioscli viososmon command
is added to understand the hang detection interval and the action when
the hang is detected. This support requires POWER firmware
version FW
1030, or later and VIOS Version 3.1.4.0, or later.
Support for NFSv4 Mounts on VIOS
The ioscli mount command which previously,
by default, only supported the NFSv3 mount of the AIX is updated to
support NFSv4 mounting. The changes allow VIOS to be able to invoke commands
for the following actions:
·
Setting Network File System (NFS) domain using chnfsdom from
command line interface (CLI)
The setting of the
NFS domain is accomplished by adding a Role-based access control (RBAC) support
for the chnfsdom command.
· Invoking
the NFSv4 mounting
The ioscli mount command
is updated to support invoking the NFSv4 mounting. The current ioscli
mount command defaults to NFSv3. You can invoke the “o vers=4” option with the new “-nfsvers <version> <Node: > <Directory> <
Directory>” option that is added
to the ioscli mount command. The values
that are supported for the version are 3 and 4.
Note: The ioscli
mount command
supports NFS versions that are supported by the AIX
mount
command.
· Starting
the nfsrgyd daemon
For version 4, if
the mount is successful, a check is done to see if the nfsrgyd daemon is
already started. And if it has not yet started, the nfsrgyd daemon is
started.
VIOS 3.1.4.41 can run on any of the following Power
Systems:
POWER 8 or later.
The following requirements and limitations apply to Shared Storage Pool
(SSP) features and any associated virtual storage enhancements.
Software Installation
SSP Configuration
|
Feature |
Min |
Max |
|
Number of
VIOS Nodes in Cluster |
1 |
16* |
|
Number of
Physical Disks in Pool |
1 |
1024 |
|
Number of
Virtual Disks (LUs) Mappings in Pool |
1 |
8192 |
|
Number of
Client LPARs per VIOS node |
1 |
250* |
|
Capacity
of Physical Disks in Pool |
10GB |
16TB |
|
Storage
Capacity of Storage Pool |
10GB |
512TB |
|
Capacity
of a Virtual Disk (LU) in Pool |
1GB |
4TB |
|
Number of
Repository Disks |
1 |
1 |
|
Capacity
of Repository Disk |
512MB |
1016GB |
|
Number of
Client LPARs per Cluster |
1 |
2000 |
Prerequisites for expanded support:
Here are the new maximum values for each of these
configuration options, if the associated hardware specification has been met:
|
Feature |
Default
Max |
High
Spec Max |
|
Number of
VIOS Nodes in Cluster |
16 |
24 |
|
Number of
Client LPARs per VIOS node |
250 |
400 |
Network Configuration
Storage Configuration
Shared Storage Pool capabilities and limitations
Please ensure that your rootvg contains at
least 30 GB and that there is at least 4GB free space before you attempt to update to
Update Release 3.1.4.41. Run the lsvg
rootvg command, and then ensure there
is enough free space.
Example:
$ lsvg rootvg |
|
|
|
VOLUME GROUP: |
rootvg |
VG IDENTIFIER: |
00f6004600004c000000014306a3db3d |
VG STATE: |
active |
PP SIZE: |
64 megabyte(s) |
VG PERMISSION: |
read/write |
TOTAL PPs: |
511 (32704 megabytes) |
MAX LVs: |
256 |
FREE PPs: |
64 (4096 megabytes) |
LVs: |
14 |
USED PPs: |
447 (28608 megabytes) |
OPEN LVs: |
12 |
QUORUM: |
2 (Enabled) |
TOTAL PVs: |
1 |
VG DESCRIPTORS: |
2 |
STALE PVs: |
0 |
STALE PPs: |
0 |
ACTIVE PVs: |
1 |
AUTO ON: |
yes |
MAX PPs per VG: |
32512 |
|
|
MAX PPs per PV: |
1016 |
MAX PVs: |
32 |
LTG size (Dynamic): |
256 kilobyte(s) |
AUTO SYNC: |
no |
HOT SPARE: |
no |
BB POLICY: |
relocatable |
PV RESTRICTION: |
none |
INFINITE RETRY: |
no |
A single, merged
lpp_source is not supported for VIOS that uses SDDPCM. However, if you use SDDPCM,
you can still enable a single boot update by using the alternate method
described at the following location:
SDD and SDDPCM migration
procedures when migrating VIOS from version 1.x to version 2.x
Virtual I/O Server support for Power Systems
VIOS Update
Release 3.1.4.41 may be applied directly to any VIOS at level 3.1.0.00.
The VIOS must
first be upgraded to 3.1.0.00 before the 3.1.4.41 update can be applied. To learn more about how to do that, please
read the information provided here.
Warning: The
update may fail if there is a loaded media repository.
To check for a
loaded media repository, and then unload it, follow these steps.
1. To check for loaded images, run the following command:
$ lsvopt
The Media column lists any loaded media.
2. To unload media images, run the following commands on all Virtual Target
Devices that have loaded images.
$ unloadopt
-vtd <file-backed_virtual_optical_device >
3. To verify that all media are unloaded, run the following command again.
$ lsvopt
The command output should show No
Media for all VTDs.
The Virtual I/O
Server (VIOS) Version 2.2.2.1 or later, supports rolling updates for SSP
clusters. The VIOS can be updated to Update Release 3.1.4.41 using rolling
updates.
Non-disruptive
rolling updated to VIOS 3.1 requires all SSP nodes to be at VIOS 2.2.6.31 or
later. See detailed instructions in the VIOS 3.1 documentation
The rolling
updates enhancement allows the user to apply Update Release 3.1.4.41 to the VIOS
logical partitions in the cluster individually without causing an outage in the
entire cluster. The updated VIOS logical partitions cannot use the new SSP
capabilities until all VIOS logical partitions in the cluster are updated.
To upgrade the
VIOS logical partitions to use the new SSP capabilities, ensure that the
following conditions are met:
·
All VIOS logical partitions must have
VIOS Update Release version 2.2.6.31 or later installed.
·
All VIOS logical partitions must be
running. If any VIOS logical partition in the cluster is not running, the
cluster cannot be upgraded to use the new SSP capabilities.
Instructions: Verify
the cluster is running at the same level as your node.
1. Run the following command:
$ cluster -status -verbose
2. Check the Node Upgrade Status field, and you should see one of the
following terms:
UP_LEVEL: This means that the software level of the logical partition is higher
than the software level the cluster is running at.
ON_LEVEL: This means the software level of the logical partition and the
cluster are the same.
There is now a method
to verify the VIOS update files before installation. This process requires
access to openssl by the 'padmin' User, which can be accomplished by creating a
link.
Instructions: Verifying VIOS update files.
To verify the VIOS
update files, follow these steps:
1. $ oem_setup_env
2. Create a link to openssl
# ln
-s /usr/bin/openssl /usr/ios/utils/openssl
3.
Verify the link to openssl was created
# ls
-alL /usr/bin/openssl /usr/ios/utils/openssl
4.
Verify that both files display similar
owner and size
5. # exit
Use one of the
following methods to install the latest VIOS Service Release. As with all
maintenance, you should create a VIOS backup before making changes.
If you are running
a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.
Note:
While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be
ignored.
Version Specific Warning: Version 2.2.2.1, 2.2.2.2, 2.2.2.3, or 2.2.3.1
You must run updateios command twice to get
bos.alt_disk_install.boot_images fileset update problem fixed.
Run the following
command after the step of "$ updateios –accept –install –dev <directory_name >" completes.
$ updateios
–accept –dev <directory_name >
Depending on the
VIOS level, one or more of the LPPs below may be reported as "Missing
Requisites", and they may be ignored.
MISSING
REQUISITES:
X11.loc.fr_FR.base.lib 4.3.0.0 # Base Level Fileset bos.INed 6.1.6.0 # Base Level Fileset bos.loc.pc.Ja_JP 6.1.0.0 # Base Level Fileset bos.loc.utf.EN_US 6.1.0.0 # Base Level Fileset bos.mls.rte 6.1.x.x # Base Level Fileset
Warning: If VIOS rules
have been deployed.
During update, there have been occasional issues with VIOS Rules files getting
overwritten and/or system settings getting reset to their default values.
To ensure that this doesn’t affect you, we
recommend making a backup of the current rules file. This file is located here:
/home/padmin/rules/vios_current_rules.xml
First, to capture your current system settings, run this command:
$ rules
-o capture
Then, either copy the file to a backup
location, or save off a list of your current rules:
$ rules -o list > rules_list.txt
After this is complete, proceed to update
as normal. When your update is complete,
check your current rules and ensure that they still match what is desired. If not, either overwrite the original rules
file with your backup, or proceed to use the ‘rules -o modify’ and/or ‘rules -o
add’ commands to change the rules to match what is in your backup file.
Finally, if you’ve failed to back up your
rules, and are not sure what the rules should be, you can deploy the
recommended VIOS rules by using the following command:
$ rules -o deploy -d
Then, if you wish to copy these new VIOS
recommended rules to your current rules file, just run:
$ rules -o capture
Note: This will
overwrite any customized rules in the current rules file.
Applying Updates
Warning:
If the target node
to be updated is part of a redundant VIOS pair, the VIOS partner node must be
fully operational before beginning to update the target node.
Note:
For VIOS nodes
that are part of an SSP cluster, the partner node must be shown in 'cluster
-status ' output as having a
cluster status of OK and a pool status of OK. If the target node is updated
before its VIOS partner is fully operational, client LPARs may crash.
Instructions: Applying updates to a VIOS.
2. Using ftp, transfer the update file(s) to the directory you created.
To apply updates from a remotely mounted file system, and the remote file
system is to be mounted read-only, follow the steps:
The update release
can be burned onto a CD by using the ISO image file(s). To apply updates from
the CD/DVD drive, follow the steps:
$ shutdown
-restart
Note: If shutdown –restart command failed, run swrole –PAdmin for padmin to set authorization and
establish access to the shutdown command properly.
$ clstartstop
-start -n <cluster_name >
-m <hostname >
$ ioslevel
Instructions: Checking for an incomplete installation caused by a loaded media
repository.
After installing
an Update Release, you can use this method to determine if you have encountered
the problem of a loaded media library.
Check the Media
Repository by running this command:
$ lsrep
If the command
reports: "Unable to retrieve repository data due to incomplete repository
structure," then you have likely encountered this problem during the
installation. The media images have not been lost and are still present in the
file system of the virtual media library.
Running the lsvopt command should show the media images.
Instructions: Recovering from an incomplete installation
caused by a loaded media repository.
To recover from this
type of installation failure, unload any media repository images, and then
reinstall the ios.cli.rte package. Follow these steps:
1. Unload any media images
$ unloadopt
-vtd <file-backed_virtual_optical_device>
2. Reinstall the ios.cli.rte fileset by running the following
commands.
To escape the
restricted shell:
$ oem_setup_env
To install the failed fileset:
# installp
–Or –agX ios.cli.rte –d <device/directory >
To return to the restricted
shell:
# exit
3. Restart the VIOS.
$ shutdown
–restart
4. Verify that the Media Repository is operational by running this command:
$ lsrep
|
APAR |
Description |
|
IJ41832 |
Install images for bos.loc.utf.JA_JP |
|
IJ43761 |
SECLDAPCLNTD NESTED GROUP HANG, CORE, OR ERRORS WITH ITDS |
|
IJ44713 |
PASSWORD CHANGE ATTEMPT FAILS |
|
IJ45602 |
LDAP SERVER MARKED DOWN DOESN'T RECOVER QUICKLY ENOUGH |
|
IJ46457 |
INCORRECT ERROR ON LDAP USER PASSWORD CHANGE |
|
IJ47166 |
CHDEV TO CHANGE AN SEA FAILS WITH RBAC USER |
|
IJ47358 |
NPIV CLIENT REQUESTED IMPLICIT LOGO, DRIVER SENT EXPLICIT LOGO |
|
IJ47389 |
SECLDAPCLNTD GROUP CACHE NOT ALWAYS WORKING |
|
IJ47750 |
SECLDAPCLNTD SLOW MEMORY LEAK |
|
IJ47782 |
ASO NOT DISABLED AFTER UPDATE FROM VIOS 3.1.4.0 TO 3.1.4.10 |
|
IJ47943 |
Trying to remove fcs adapter on vfc client crashes partition |
|
IJ48303 |
SECLDAPCLNTD GROUP CACHE IMPROVEMENT |
|
IJ48532 |
LOGINS HANG WITH TRUNCATED LASTLOG FILE |
|
IJ48558 |
MAKE SECLDAPCLNTD SERVER CONNECTION TIMEOUT ADJUSTABLE |
|
IJ48719 |
SNMPDV3 LOGS INCORRECT MESSAGE WHEN STOPSRC IS ISSUED |
|
IJ48748 |
EXPR: NOT FOUND ERRORS WHILE RESTORING MULTI VOLUME MKSYSB |
|
IJ48791 |
SYSTEM MAY CRASH WITH LVM SERIALIZED IO ENABLED ON LV |
|
IJ48829 |
ERRORS IN NMON "PEAK KB/S READ+WRITE" COLUMN |
|
IJ48838 |
NIM MKSYSB RESTORE MAY HANG FOR ENTERPRISE_CLOUD EDITION |
|
IJ48881 |
ISSUE FACED WHILE CHANGING THE IKE ENTRIES USING SMITTY TOOL |
|
IJ48961 |
LKU: SURROGATE CRASH IN "IN6_DELMULTI_SOURCE" |
|
IJ49016 |
FCSTAT OUTPUT FOR PEND_CMD'S MAY CONTINUE TO INCREMENT |
|
IJ49035 |
INVALID TZ WILL CAUSE DBN ELECTION INSTABILITY |
|
IJ49041 |
ALT_DISK_COPY UNFORMATTED ERRORS ON EFS MOUNT POINTS |
|
IJ49046 |
MKGROUP OF LOCAL GROUP DOESN'T ALLOW ADDING NIS USERS |
|
IJ49093 |
BIND 9.16.26-OCT-CVE-2023-3341 |
|
IJ49123 |
VIOD_BKPS DIR CONTAINS TOO MANY LOGS |
|
IJ49148 |
AIXPERT COMINETDCONF SCRIPT |
|
IJ49185 |
MULTICAST BIND FAILS ON VLAN |
|
IJ49205 |
VIOS_VFC_HOST WITH ERROR NPIV_ERR_006E RC:EINVAL ALREADY STARTED |
|
IJ49206 |
DSI NPIV_REAL_FCSCSI_ASYNC |
|
IJ49247 |
MLXENTDD DRIVER IS NOT HAVING ENOUGH DMA_SIZE MEMORY |
|
IJ49323 |
COMMAND CHDEV SAVE INCORRECT IPV4 ALIAS NETMASK IN ODM |
|
IJ49324 |
BOS.ESAGENT UPGRADE MAY FAIL IF IBM.ESAGENT WAS ACTIVATED |
|
IJ49325 |
crashed at lock_free_com+000058 |
|
IJ49326 |
hmcauth command failing with c_rsh -e |
|
IJ49328 |
wcsxfrm_l() returns incorrect value when argument 'n' is 0 |
|
IJ49330 |
MLXCENTDD CRASHED AT MLXCENT_CMDQ_RESERVE_MBOX_TYPE |
|
IJ49331 |
VF INTERFACE ATTACHED TO VNIC NOT REMOVED DURING LPM |
|
IJ49335 |
Probable system crash in cvfsc_cmd_recv |
|
IJ49337 |
Rolling upgrade may fail and SSP DB may become unavailable. |
|
IJ49338 |
htxcmdline -createmdt command got hung |
|
IJ49339 |
DBN connection fails after upgrade to VIOS 4.1 |
|
IJ49342 |
RESTORE MAY DISPLAY WRONG FILE TIMESTAMP |
|
IJ49343 |
Exitstatus wasn't found in standard output |
|
IJ49344 |
od -t fails with exit code zero |
|
IJ49345 |
SWITCH.PRT FAILS IF THERE ARE EXISTING JOBS |
|
IJ49347 |
Shell returns non-zero exit status |
|
IJ49353 |
Driver unrecoverable if rmdev,nddctl,entstat run in parallel |
|
IJ49428 |
Error msg handeling for Phase2/3 foralt_disk_copy. |
|
IJ49431 |
SSL handshake error when using proxy server |
|
IJ49432 |
Verify failed, no proper error message |
|
IJ49433 |
vNIC Adapter reset causes ping to fail |
|
IJ49457 |
MEMORY LEAK IN PERFSTAT_PROCESS LIBPERFSTAT API |
|
IJ49492 |
nim -o cust -a live_update=yes hangs |
|
IJ49494 |
nim_master_recover cmd removed alt_mstr |
|
IJ49499 |
SRIOV VF Diagnostic stalled or results in failure |
|
IJ49500 |
Validation failure of yc03w0p13 yc03w |
|
IJ49577 |
KSH CAN DUMP CORE WHEN DISCONNECTING REMOTE LOGIN CONNECTION |
|
IJ49601 |
Microcode installation message |
|
IJ49666 |
IO HANG IN CAVIUM FIBRE ADAPTER AFTER LINK DOWN EVENT. |
|
IJ49704 |
GDLC IN ETHERCHANNEL ENVIRONMENT, MAY NOT WORK PROPERLY. |
|
IJ49729 |
LI #OEP Bar0 changes for honouring odm configuration |
|
IJ49756 |
OFED crash in cm_alloc_response_msg() while interface detached |
|
IJ49815 |
fwupdate on multipath splitter device ret wrong msg |
|
IJ49853 |
nim LU hangs after completion |
|
IJ49870 |
NIM MKSYSB RESTORE HANG DUE TO DATADAEMON CORE DUMP |
|
IJ49883 |
INCORRECT PRINT QUEUE STATUS SHOW |
|
IJ49892 |
SCSI protocol driver name is hardcoded in the LPM log |
|
IJ49893 |
Inactive LPM is failing with LU validation syst |
|
IJ49902 |
Update kernel copyright notice for 2024 |
|
IJ49939 |
LPM adapter fails after an adapter reset on VFC client. |
|
IJ49965 |
A potential security issue exists |
|
IJ50039 |
RXQ KPROCS CAN RUN CONTINUOUSLY DISABLED AT INTPRI3 ON SOME CPUS |
|
IJ50040 |
Crash while upgrading firmware on Mellanox network adapter |
|
IJ50045 |
BOOT OR DUMP FAILURE ON NVME DISKS DUE TO INCORRECT FW PATH NAME |
|
IJ50097 |
NPIV CLIENT REQ IMPLICIT LOGO, QL DRIVER SENT EXPLICIT LOGO |
|
IJ50098 |
/proc filesystem missing after OS migration |
|
IJ50101 |
NETISR.H INCLUDES FILE SYS/LIBSYSP.H WHICH IS NOT SHIPPED |
|
IJ50228 |
Linker asked to preserve internal global warning from libLTO |
|
IJ50229 |
PVID load up criteria missing in datadaemon |
|
IJ50236 |
Kbd/mouse not detected with KVM switch |
|
IJ50269 |
DURING LKU RESTORATION OF THE TCPTR TABLE MAY CAUSE A HANG |
|
IJ50407 |
NIMHTTP WITH SECURE NIMSH FAILS |
|
IJ50409 |
mksysb to "client" successful parallel migration gen |
|
IJ50410 |
nimadm cmd help changes for bootlist and reboot flags |
|
IJ50411 |
Wrong FFC Code For an SRN-802 |
|
IJ50422 |
SAVEBASE CAN FAIL WITH 4K DISKS IN ROOTVG AND LARGE ODM |
|
IJ50438 |
errpt while promoting data from a 4K device when it is cached. |
|
IJ50501 |
vnic kproc names should not have space characters |
|
IJ50517 |
sysdumpdev -e hung looping in
aixdiskpcmke:getPathDataSize |
|
IJ50598 |
FTPD IS INCONSISTENT WHEN "READWRITE:" STATEMENT IS
INVALID |
|
IJ50599 |
POSSIBLE CONTINUOUS FCA_ERR6 0X2F AND FCA_ERR2 0X27 ERRPT ERRORS |
|
IJ50602 |
A potential security issue exists |
|
IJ50627 |
updateios failed for 3.1.4.40 with full FS |
|
IJ50663 |
restore memory leaks |
|
IJ50664 |
Improper error msg for wrong country code |
|
IJ50665 |
Commands such as lsmpio, lspath probably will hang |
|
IJ50703 |
NIM hangs even after LKU is completed successfully |
|
IJ50716 |
LLDPCTL ADD FAILING ON VIOS 3.1.4.21 |
|
IJ50722 |
LSPV CORE DUMPS IN ODM_GET_FIRST() |
|
IJ50770 |
ike cmd=list db shows incorrect Remote IP Address |
|
IJ50772 |
AIX NFSv4 Client to Linux NFS Server- fail to copy |
|
IJ50870 |
DSI during varyoffvg when space reclamation is in progress. |
|
IJ50939 |
SNAP DO NOT COLLECT POSTGRES SSP DB IN VIOS 3.1.4.31 /4.1.0.X |
|
IJ51182 |
ioslevel change for 72Z to 3.1.4.41 and for 73D to 4.1.0.21 |
|
IJ51184 |
IO fails before recovery_wait time with cablepul |
|
IJ51214 |
crashed in ct_hook1 |