IBM Support

System Event Log fullness errors - Advanced Management Module, Option 25R5778

Troubleshooting


Problem

When the System Event Log (SEL) on the blade is full, the Advanced Management Module (AMM) is reporting a SEL Fullness Error in the event logs. The following is an example of the event: 37 E Blade_03 03/24/08, 13:00:02 (SN#YK30517BX15H) System mgmt software (SEL fullness) SEL fullness over non- recoverable threshold.

Resolving The Problem

Source

RETAIN tip: H193260

Issue

When the System Event Log (SEL) on the blade is full, the Advanced Management Module (AMM) is reporting a SEL Fullness Error in the event logs.

The following is an example of the event:

  37 E Blade_03 03/24/08, 13:00:02 (SN#YK30517BX15H) System mgmt software (SEL fullness) SEL fullness over non- recoverable threshold.

Affected configurations

This tip is not machine specific.

The system is configured with one or more of the following IBM Options:

  • BladeCenter Advanced Management Module, Option 25R5778

This tip is not software specific.

Additional information

To stay constant with legacy blades, this event is being removed from the SEL. This event should not be seen by the user. The SEL log is not controlled by the AMM. This event does not cause the blade LED to be lit.

The event will occur due to the SEL log on the blade filling up. This triggers a sensor to report the blade, but this information is not needed by the user.

The deleting of the event is fixed in the AMM release of v40.

Document Location

Worldwide

Operating System

System x Hardware Options:All operating systems listed

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU02YEH","label":"System x Hardware Options->Advanced Management Module (AMM)->Advanced Management Module (AMM)->25R5778"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]