Troubleshooting
Problem
This document provides information on switching from XDA to XDN with SAP applications.
Resolving The Problem
This document provides information on switching from XDA to XDN with SAP applications.
| 1. | The master switch between the NEW technology (XDN) and the old (XDA) is accomplished with Option 50 in the Database menu of the Central Instance: a. Sign on as <SID>OFR. b. Select the following: -- Option 4. SAP Database -- Option 50. Change Database Driver for SAP (XDA <-> XDN) ![]() c. The SETDBDRV menu appears which will set profile parameters in DEFAULT.PFL. (Use F1 for Help). ![]() (Trying to switch on a non-central instance will return: ERROR: main: Can't Install on this Host). |
| 2. | To disable a particular SAP instance, add the following to the INSTANCE profile: dbs/db4/driver_type = XDA |
| 3. | To take advantage of new features, you can *optionally* make the following changes to INSTANCE profiles: Windows / Linux Application Instances: REMOVE: dbs_db4_da_cache_size ADD: dbs/db4/dbsl_buffersize = 524288 IBM i 2-Tier (Only needed for 640): ADD: dbs/db4/allow_cancel = 1 |
| 4. | Once changed, the application servers must be restarted for the change to take effect. Windows requires a restart of the SAP<SID>_nn service also (so the profile parameters are re-read from the file). |
| 5. | The SAP work process developer trace shows relevant information: C driver = DBSLDirectDrive C dbhost = as0012 C dbhostport = 9622 C da_cache_size = 100 C dbsl_buffersize = 131072 C dbjobname = XDNS4U8000 C dbjobuser = S4UOFR C dbjobno = 326633 C allow_cancel = ON |
| 6. | To see active database server jobs on the central instance, do the following: a. Sign on as <SID>OFR. b. Select the following: -- Option 1. General SAP Tasks -- Option 7. Work with SAP Database Server Jobs __ XDNS4ULSN - Database Listener for SID='S4U' __ XDNS4U0100 - Database Job for SID='S4U', INST=01, WP=00 __ XDNS4UCCMS - CCMS Job |