Troubleshooting
Problem
RETAIN Tip H024933: Services failed to start installing Windows NT 4.0 using ServerGuide.
Resolving The Problem
Source
RETAIN Tip H024933
Services failed to start installing Windows NT 4.0 using ServerGuide.
Symptoms
The following errors will show up at the end of the installation of NT 4.0 in the Event Viewer:
- Event ID: 7000, Source: Service Control Manager, Type: Error, Category: None Description: The I2C service failed to start due to the following error: The system cannot find the file specified.
- Event ID: 7000, Source: Service Control Manager, Type: Error, Category: None Description: The LM78 service failed to start due to the following error: The system cannot find the file specified.
- Event ID: 7000, Source: Service Control Manager, Type: Error, Category: None Description: The PMEM service failed to start due to the following error: The system cannot find the file specified.
Affected configurations
The system is a Netfinity 1000 server, type 8477, any model.
The system is configured with ServerGuide 4.1.2.
The system is configured with one of the following:
- NT 4.0 Server
- NT 4.0 Server Enterprise Edition
Solution
This will be fixed in ServerGuide 5.0.
Workaround
1. Copy all the files located in C:\%PROGRAMD% directory to C:\WINNT\SYSTEM32\DRIVERS.
2. Re-boot the system.
Details
When the I2C, LM78 and PMEM services are installed by ServerGuide 4.1.2 the registry is modified to look for the drivers required by each service into the C:\WINNT\SYSTEM32\DRIVERS directory; however the drivers are not there, they are copied into the C:\%PROGRAMD% directory instead.
Document Location
Worldwide